Skip to main content
MID 50K-HU vs GW50K-ET-10 12 of 26 identical Swap Change inverters

Growatt MID 50K-HU vs GoodWe GW50K-ET-10

Growatt MID 50K-HU
Growatt
MID 50K-HU
50 kW 97.2 % euro Hybrid
VS
GoodWe GW50K-ET-10
GoodWe
GW50K-ET-10
50 kW 97.8 % euro Hybrid
The verdict

14 differences, and they point both ways

The largest is european efficiency: 0.6 pp more efficient. 12 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
12 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 26 parameters
Parameter MID 50K-HU GW50K-ET-10 Difference
European efficiency 97.2 % 97.8 % 0.6 pp more efficient
Max input current per tracker 40.0 A 42.0 A 2.0 A more headroom
Max AC power 50.00 kW 55.00 kW 5.00 kW apart
Max PV power 100.00 kW 75.00 kW 25.00 kW apart
DC/AC ratio 2.00 1.50 0.50 more oversizing headroom
Max charge current 42 A 100 A 58 A faster charging
Weight 50.0 kg 65.0 kg 15.0 kg lighter
Max efficiency 98.6 % 98.1 % 0.5 pp more efficient
Nominal AC voltage 400 V 380 V 20 V apart
Max AC current 75.8 A 83.3 A 7.5 A apart
Weight per kW 1.0 kg/kW 1.3 kg/kW 0.3 kg/kW lighter
MPPT voltage range 200-1000 V 165-850 V 200-1000 V vs 165-850 V
Battery voltage 600-980 V 200-800 V 600-980 V vs 200-800 V
Dimensions 570x680x256 mm 660x520x260 mm 570x680x256 mm vs 660x520x260 mm
02

Full specification

Parameter MID 50K-HU GW50K-ET-10 Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 50.00 kW 55.00 kW 5.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 380 V 20 V apart
Max AC current 75.8 A 83.3 A 7.5 A apart
PV input
Max PV power 100.00 kW 75.00 kW 25.00 kW apart
DC/AC ratio 2.00 1.50 +0.50 for MID 50K-HU
Max DC voltage 1000 V 1000 V Same
MPPT voltage range 200-1000 V 165-850 V 200-1000 V vs 165-850 V
Start voltage 160 V 160 V Same
MPP trackers - - Neither datasheet publishes this
Strings per tracker 2 2 Same
Max input current per tracker 40.0 A 42.0 A +2.0 A for GW50K-ET-10
Efficiency
European efficiency 97.2 % 97.8 % +0.6 pp for GW50K-ET-10
Max efficiency 98.6 % 98.1 % +0.5 pp for MID 50K-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 200-800 V 600-980 V vs 200-800 V
Max charge current 42 A 100 A +58 A for GW50K-ET-10
Backup power 30.0 kW - Not published by GoodWe
Physical
Weight 50.0 kg 65.0 kg -15.0 kg for MID 50K-HU
Weight per kW 1.0 kg/kW 1.3 kg/kW -0.3 kg/kW for MID 50K-HU
Dimensions 570x680x256 mm 660x520x260 mm 570x680x256 mm vs 660x520x260 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise 55 dB - Not published by GoodWe
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by GoodWe
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
Growatt MID 50K-HU vs Ginlong Solis S6-EH3P50K-H
11 differences, the largest is max efficiency
Same type, similar size
Deye
Growatt MID 50K-HU vs Deye SUN-50K-SG01HP3-EU-BM4
16 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MID 50K-HU vs Growatt WIT 50K-A-US / WIT 50K-AU-US
7 differences, the largest is weight
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.