Parameter
MID 50K-HU
GW50K-ET-10
Difference
European efficiency
97.2 %
97.8 %
0.6 pp more efficient
Max input current per tracker
40.0 A
42.0 A
2.0 A more headroom
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Max PV power
100.00 kW
75.00 kW
25.00 kW apart
DC/AC ratio
2.00
1.50
0.50 more oversizing headroom
Max charge current
42 A
100 A
58 A faster charging
Weight
50.0 kg
65.0 kg
15.0 kg lighter
Max efficiency
98.6 %
98.1 %
0.5 pp more efficient
Nominal AC voltage
400 V
380 V
20 V apart
Max AC current
75.8 A
83.3 A
7.5 A apart
Weight per kW
1.0 kg/kW
1.3 kg/kW
0.3 kg/kW lighter
MPPT voltage range
200-1000 V
165-850 V
200-1000 V vs 165-850 V
Battery voltage
600-980 V
200-800 V
600-980 V vs 200-800 V
Dimensions
570x680x256 mm
660x520x260 mm
570x680x256 mm vs 660x520x260 mm
02
Full specification
Parameter
MID 50K-HU
GW50K-ET-10
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
380 V
20 V apart
Max AC current
75.8 A
83.3 A
7.5 A apart
PV input
Max PV power
100.00 kW
75.00 kW
25.00 kW apart
DC/AC ratio
2.00
1.50
+0.50 for MID 50K-HU
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
200-1000 V
165-850 V
200-1000 V vs 165-850 V
Start voltage
160 V
160 V
Same
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
42.0 A
+2.0 A for GW50K-ET-10
Efficiency
European efficiency
97.2 %
97.8 %
+0.6 pp for GW50K-ET-10
Max efficiency
98.6 %
98.1 %
+0.5 pp for MID 50K-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
200-800 V
600-980 V vs 200-800 V
Max charge current
42 A
100 A
+58 A for GW50K-ET-10
Backup power
30.0 kW
-
Not published by GoodWe
Physical
Weight
50.0 kg
65.0 kg
-15.0 kg for MID 50K-HU
Weight per kW
1.0 kg/kW
1.3 kg/kW
-0.3 kg/kW for MID 50K-HU
Dimensions
570x680x256 mm
660x520x260 mm
570x680x256 mm vs 660x520x260 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
55 dB
-
Not published by GoodWe
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by GoodWe
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Growatt MID 50K-HU vs Ginlong Solis S6-EH3P50K-H
11 differences, the largest is max efficiency
Same type, similar size
Deye
Growatt MID 50K-HU vs Deye SUN-50K-SG01HP3-EU-BM4
16 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MID 50K-HU vs Growatt WIT 50K-A-US / WIT 50K-AU-US
7 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.