Skip to main content
MID 50K-HU vs WIT 50K-A-US / WIT 50K-AU-US 8 of 15 identical Swap Change inverters

Growatt MID 50K-HU vs Growatt WIT 50K-A-US / WIT 50K-AU-US

Growatt MID 50K-HU
Growatt
MID 50K-HU
50 kW 97.2 % euro Hybrid
VS
Growatt WIT 50K-A-US / WIT 50K-AU-US
Growatt
WIT 50K-A-US / WIT 50K-AU-US
50 kW Hybrid
The verdict

MID 50K-HU leads on the differences that matter

The largest is weight: 70.0 kg lighter. 8 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.

See all 7 differences
How alike are they
8 of 15 comparable
parameters are identical
identical differs not published
01

What actually differs

7 of 15 parameters
Parameter MID 50K-HU WIT 50K-A-US / WIT 50K-AU-US Difference
Weight 50.0 kg 120.0 kg 70.0 kg lighter
Weight per kW 1.0 kg/kW 2.4 kg/kW 1.4 kg/kW lighter
Nominal AC voltage 400 V 480 V 80 V apart
Max AC current 75.8 A 66.2 A 9.6 A apart
Ingress protection IP66 NEMA/IP66 IP66 vs NEMA/IP66
Battery voltage 600-980 V 750-1000 V 600-980 V vs 750-1000 V
Dimensions 570x680x256 mm 1200x820x510 mm 570x680x256 mm vs 1200x820x510 mm
02

Full specification

Parameter MID 50K-HU WIT 50K-A-US / WIT 50K-AU-US Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 50.00 kW 50.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 480 V 80 V apart
Max AC current 75.8 A 66.2 A 9.6 A apart
PV input
Max PV power 100.00 kW - Not published by Growatt
DC/AC ratio 2.00 - Not published by Growatt
Max DC voltage 1000 V - Not published by Growatt
MPPT voltage range 200-1000 V - Not published by Growatt
Start voltage 160 V - Not published by Growatt
MPP trackers - - Neither datasheet publishes this
Strings per tracker 2 - Not published by Growatt
Max input current per tracker 40.0 A - Not published by Growatt
Efficiency
European efficiency 97.2 % - Not published by Growatt
Max efficiency 98.6 % - Not published by Growatt
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 750-1000 V 600-980 V vs 750-1000 V
Max charge current 42 A - Not published by Growatt
Backup power 30.0 kW - Not published by Growatt
Physical
Weight 50.0 kg 120.0 kg -70.0 kg for MID 50K-HU
Weight per kW 1.0 kg/kW 2.4 kg/kW -1.4 kg/kW for MID 50K-HU
Dimensions 570x680x256 mm 1200x820x510 mm 570x680x256 mm vs 1200x820x510 mm
Ingress protection IP66 NEMA/IP66 IP66 vs NEMA/IP66
Cooling forced-air forced-air Same
Noise 55 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes - Not published by Growatt
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
Growatt MID 50K-HU vs GoodWe GW50K-ET-10
14 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MID 50K-HU vs Ginlong Solis S6-EH3P50K-H
11 differences, the largest is max efficiency
Same type, similar size
Deye
Growatt MID 50K-HU vs Deye SUN-50K-SG01HP3-EU-BM4
16 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.