Skip to main content
WIT 50K-H / WIT 50K-HU vs MID 50K-HU 10 of 24 identical Swap Change inverters

Growatt WIT 50K-H / WIT 50K-HU vs Growatt MID 50K-HU

Growatt WIT 50K-H / WIT 50K-HU
Growatt
WIT 50K-H / WIT 50K-HU
50 kW Hybrid
VS
Growatt MID 50K-HU
Growatt
MID 50K-HU
50 kW 97.2 % euro Hybrid
The verdict

MID 50K-HU leads on the differences that matter

The largest is max dc voltage: 100 V apart. 10 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
10 of 24 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 24 parameters
Parameter WIT 50K-H / WIT 50K-HU MID 50K-HU Difference
Max DC voltage 1100 V 1000 V 100 V apart
Max input current per tracker 32.0 A 40.0 A 8.0 A more headroom
Max efficiency 98.0 % 98.6 % 0.6 pp more efficient
Max AC power 55.00 kW 50.00 kW 5.00 kW apart
Max PV power 109.20 kW 100.00 kW 9.20 kW apart
Weight 133.0 kg 50.0 kg 83.0 kg lighter
Weight per kW 2.7 kg/kW 1.0 kg/kW 1.7 kg/kW lighter
DC/AC ratio 2.18 2.00 0.18 more oversizing headroom
Max AC current 83.3 A 75.8 A 7.5 A apart
Start voltage 195 V 160 V 35 V earlier start
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 180-800 V 200-1000 V 180-800 V vs 200-1000 V
Battery voltage 600~1000V (for 3P3W) / 680~1000V (for 3P4W) 600-980 V 600~1000V (for 3P3W) / 680~1000V (for 3P4W) vs 600-980 V
Dimensions 1350x820x510 mm 570x680x256 mm 1350x820x510 mm vs 570x680x256 mm
02

Full specification

Parameter WIT 50K-H / WIT 50K-HU MID 50K-HU Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 55.00 kW 50.00 kW 5.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 83.3 A 75.8 A 7.5 A apart
PV input
Max PV power 109.20 kW 100.00 kW 9.20 kW apart
DC/AC ratio 2.18 2.00 +0.18 for WIT 50K-H / WIT 50K-HU
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 180-800 V 200-1000 V 180-800 V vs 200-1000 V
Start voltage 195 V 160 V -35 V for MID 50K-HU
MPP trackers - - Neither datasheet publishes this
Strings per tracker 2 2 Same
Max input current per tracker 32.0 A 40.0 A +8.0 A for MID 50K-HU
Efficiency
European efficiency - 97.2 % Not published by Growatt
Max efficiency 98.0 % 98.6 % +0.6 pp for MID 50K-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600~1000V (for 3P3W) / 680~1000V (for 3P4W) 600-980 V 600~1000V (for 3P3W) / 680~1000V (for 3P4W) vs 600-980 V
Max charge current - 42 A Not published by Growatt
Backup power - 30.0 kW Not published by Growatt
Physical
Weight 133.0 kg 50.0 kg -83.0 kg for MID 50K-HU
Weight per kW 2.7 kg/kW 1.0 kg/kW -1.7 kg/kW for MID 50K-HU
Dimensions 1350x820x510 mm 570x680x256 mm 1350x820x510 mm vs 570x680x256 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air forced-air Same
Noise - 55 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes Yes Same
Integrated DC switch - Yes Not published by Growatt
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
Growatt WIT 50K-H / WIT 50K-HU vs GoodWe GW50K-ET-10
12 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt WIT 50K-H / WIT 50K-HU vs Ginlong Solis S6-EH3P50K-H
14 differences, the largest is max dc voltage
Same type, similar size
Deye
Growatt WIT 50K-H / WIT 50K-HU vs Deye SUN-50K-SG01HP3-EU-BM4
11 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MID 50K-HU vs Growatt WIT 50K-A-US / WIT 50K-AU-US
7 differences, the largest is weight
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.