Growatt WIT 50K-H / WIT 50K-HU vs Deye SUN-50K-SG01HP3-EU-BM4
VS
The verdict
SUN-50K-SG01HP3-EU-BM4 leads on the differences that matter
The largest is max dc voltage: 100 V apart. 11 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
11
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 22 parameters
What actually differs
Parameter
WIT 50K-H / WIT 50K-HU
SUN-50K-SG01HP3-EU-BM4
Difference
Max DC voltage
1100 V
1000 V
100 V apart
Max input current per tracker
32.0 A
36.0 A
4.0 A more headroom
Max PV power
109.20 kW
65.00 kW
44.20 kW apart
DC/AC ratio
2.18
1.30
0.88 more oversizing headroom
Weight
133.0 kg
80.0 kg
53.0 kg lighter
Weight per kW
2.7 kg/kW
1.6 kg/kW
1.1 kg/kW lighter
Max efficiency
98.0 %
97.6 %
0.4 pp more efficient
MPPT voltage range
180-800 V
150-850 V
180-800 V vs 150-850 V
Battery voltage
600~1000V (for 3P3W) / 680~1000V (for 3P4W)
160-800
600~1000V (for 3P3W) / 680~1000V (for 3P4W) vs 160-800
Start voltage
195 V
180 V
15 V earlier start
Dimensions
1350x820x510 mm
894x527x294 mm
1350x820x510 mm vs 894x527x294 mm
02
Full specification
Parameter
WIT 50K-H / WIT 50K-HU
SUN-50K-SG01HP3-EU-BM4
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
55.00 kW
55.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
83.3 A
83.4 A
Effectively the same
PV input
Max PV power
109.20 kW
65.00 kW
44.20 kW apart
DC/AC ratio
2.18
1.30
+0.88 for WIT 50K-H / WIT 50K-HU
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
180-800 V
150-850 V
180-800 V vs 150-850 V
Start voltage
195 V
180 V
-15 V for SUN-50K-SG01HP3-EU-BM4
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
32.0 A
36.0 A
+4.0 A for SUN-50K-SG01HP3-EU-BM4
Efficiency
European efficiency
-
97.0 %
Not published by Growatt
Max efficiency
98.0 %
97.6 %
+0.4 pp for WIT 50K-H / WIT 50K-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600~1000V (for 3P3W) / 680~1000V (for 3P4W)
160-800
600~1000V (for 3P3W) / 680~1000V (for 3P4W) vs 160-800
Max charge current
-
100 A
Not published by Growatt
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
133.0 kg
80.0 kg
-53.0 kg for SUN-50K-SG01HP3-EU-BM4
Weight per kW
2.7 kg/kW
1.6 kg/kW
-1.1 kg/kW for SUN-50K-SG01HP3-EU-BM4
Dimensions
1350x820x510 mm
894x527x294 mm
1350x820x510 mm vs 894x527x294 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
-
65 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Deye
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Deye
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Growatt WIT 50K-H / WIT 50K-HU vs GoodWe GW50K-ET-10
12 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt WIT 50K-H / WIT 50K-HU vs Ginlong Solis S6-EH3P50K-H
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt WIT 50K-H / WIT 50K-HU vs Growatt MID 50K-HU
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Deye SUN-50K-SG01HP3-EU-BM4 vs Growatt WIT 50K-A-US / WIT 50K-AU-US
8 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.