Growatt MOD 5000TL3-HU vs GoodWe GW5048-ESA
VS
The verdict
MOD 5000TL3-HU leads on the differences that matter
The largest is european efficiency: 0.8 pp more efficient. 8 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.
See all 19 differencesHow alike are they
8
of 27 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
19 of 27 parameters
What actually differs
Parameter
MOD 5000TL3-HU
GW5048-ESA
Difference
European efficiency
97.8 %
97.0 %
0.8 pp more efficient
Max DC voltage
1000 V
580 V
420 V apart
Max input current per tracker
20.0 A
11.0 A
9.0 A more headroom
Max efficiency
98.3 %
97.6 %
0.7 pp more efficient
Max AC power
5.50 kW
4.60 kW
0.90 kW apart
Max PV power
10.00 kW
6.50 kW
3.50 kW apart
DC/AC ratio
2.00
1.30
0.70 more oversizing headroom
Max charge current
25 A
90 A
65 A faster charging
Weight
19.0 kg
44.0 kg
25.0 kg lighter
Weight per kW
3.8 kg/kW
8.8 kg/kW
5.0 kg/kW lighter
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
8.3 A
22.8 A
14.5 A apart
Start voltage
180 V
125 V
55 V earlier start
Noise
29 dB
25 dB
4 dB quieter
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
140-1000 V
125-550 V
140-1000 V vs 125-550 V
Battery voltage
600-980 V
40-60
600-980 V vs 40-60
Dimensions
468x408x202 mm
832x516x290 mm
468x408x202 mm vs 832x516x290 mm
02
Full specification
Parameter
MOD 5000TL3-HU
GW5048-ESA
Difference
AC output
Rated AC power
5.00 kW
5.00 kW
Same
Max AC power
5.50 kW
4.60 kW
0.90 kW apart
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
8.3 A
22.8 A
14.5 A apart
PV input
Max PV power
10.00 kW
6.50 kW
3.50 kW apart
DC/AC ratio
2.00
1.30
+0.70 for MOD 5000TL3-HU
Max DC voltage
1000 V
580 V
420 V apart
MPPT voltage range
140-1000 V
125-550 V
140-1000 V vs 125-550 V
Start voltage
180 V
125 V
-55 V for GW5048-ESA
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
20.0 A
11.0 A
+9.0 A for MOD 5000TL3-HU
Efficiency
European efficiency
97.8 %
97.0 %
+0.8 pp for MOD 5000TL3-HU
Max efficiency
98.3 %
97.6 %
+0.7 pp for MOD 5000TL3-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
40-60
600-980 V vs 40-60
Max charge current
25 A
90 A
+65 A for GW5048-ESA
Backup power
-
4.6 kW
Not published by Growatt
Physical
Weight
19.0 kg
44.0 kg
-25.0 kg for MOD 5000TL3-HU
Weight per kW
3.8 kg/kW
8.8 kg/kW
-5.0 kg/kW for MOD 5000TL3-HU
Dimensions
468x408x202 mm
832x516x290 mm
468x408x202 mm vs 832x516x290 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
29 dB
25 dB
-4 dB for GW5048-ESA
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by GoodWe
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
10 yrs
-
Not published by GoodWe
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MOD 5000TL3-HU vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
13 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Growatt MOD 5000TL3-HU vs SolarEdge SE5000H
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 5000TL3-HU vs Huawei SUN2000L-5KTL
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.