Skip to main content
GW5048-ESA vs MOD 5000TL3-HU 8 of 27 identical Swap Change inverters

GoodWe GW5048-ESA vs Growatt MOD 5000TL3-HU

GoodWe GW5048-ESA
GoodWe
GW5048-ESA
5 kW 97.0 % euro Hybrid
VS
Growatt MOD 5000TL3-HU
Growatt
MOD 5000TL3-HU
5 kW 97.8 % euro Hybrid
The verdict

MOD 5000TL3-HU leads on the differences that matter

The largest is european efficiency: 0.8 pp more efficient. 8 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.

See all 19 differences
How alike are they
8 of 27 comparable
parameters are identical
identical differs not published
01

What actually differs

19 of 27 parameters
Parameter GW5048-ESA MOD 5000TL3-HU Difference
European efficiency 97.0 % 97.8 % 0.8 pp more efficient
Max DC voltage 580 V 1000 V 420 V apart
Max input current per tracker 11.0 A 20.0 A 9.0 A more headroom
Max efficiency 97.6 % 98.3 % 0.7 pp more efficient
Max AC power 4.60 kW 5.50 kW 0.90 kW apart
Max PV power 6.50 kW 10.00 kW 3.50 kW apart
DC/AC ratio 1.30 2.00 0.70 more oversizing headroom
Max charge current 90 A 25 A 65 A faster charging
Weight 44.0 kg 19.0 kg 25.0 kg lighter
Weight per kW 8.8 kg/kW 3.8 kg/kW 5.0 kg/kW lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 22.8 A 8.3 A 14.5 A apart
Start voltage 125 V 180 V 55 V earlier start
Noise 25 dB 29 dB 4 dB quieter
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 125-550 V 140-1000 V 125-550 V vs 140-1000 V
Battery voltage 40-60 600-980 V 40-60 vs 600-980 V
Dimensions 832x516x290 mm 468x408x202 mm 832x516x290 mm vs 468x408x202 mm
02

Full specification

Parameter GW5048-ESA MOD 5000TL3-HU Difference
AC output
Rated AC power 5.00 kW 5.00 kW Same
Max AC power 4.60 kW 5.50 kW 0.90 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 22.8 A 8.3 A 14.5 A apart
PV input
Max PV power 6.50 kW 10.00 kW 3.50 kW apart
DC/AC ratio 1.30 2.00 +0.70 for MOD 5000TL3-HU
Max DC voltage 580 V 1000 V 420 V apart
MPPT voltage range 125-550 V 140-1000 V 125-550 V vs 140-1000 V
Start voltage 125 V 180 V -55 V for GW5048-ESA
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 11.0 A 20.0 A +9.0 A for MOD 5000TL3-HU
Efficiency
European efficiency 97.0 % 97.8 % +0.8 pp for MOD 5000TL3-HU
Max efficiency 97.6 % 98.3 % +0.7 pp for MOD 5000TL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 40-60 600-980 V 40-60 vs 600-980 V
Max charge current 90 A 25 A +65 A for GW5048-ESA
Backup power 4.6 kW - Not published by Growatt
Physical
Weight 44.0 kg 19.0 kg -25.0 kg for MOD 5000TL3-HU
Weight per kW 8.8 kg/kW 3.8 kg/kW -5.0 kg/kW for MOD 5000TL3-HU
Dimensions 832x516x290 mm 468x408x202 mm 832x516x290 mm vs 468x408x202 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise 25 dB 29 dB -4 dB for GW5048-ESA
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by GoodWe
Integrated DC switch Yes Yes Same
Warranty
Warranty - 10 yrs Not published by GoodWe
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
GoodWe GW5048-ESA vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
7 differences, the largest is european efficiency
Same type, similar size
SolarEdge
GoodWe GW5048-ESA vs SolarEdge SE5000H
9 differences, the largest is european efficiency
Same type, similar size
Huawei
GoodWe GW5048-ESA vs Huawei SUN2000L-5KTL
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 5000TL3-HU vs Huawei SUN2000-5KTL-L1
16 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.