Skip to main content
MOD 10KTL3-XH vs SPH 10000TL-HU 6 of 25 identical Swap Change inverters

Growatt MOD 10KTL3-XH vs Growatt SPH 10000TL-HU

Growatt MOD 10KTL3-XH
Growatt
MOD 10KTL3-XH
10 kW 98.1 % euro Hybrid
VS
Growatt SPH 10000TL-HU
Growatt
SPH 10000TL-HU
10 kW Hybrid
The verdict

MOD 10KTL3-XH leads on the differences that matter

The largest is max dc voltage: 575 V apart. 6 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.

See all 19 differences
How alike are they
6 of 25 comparable
parameters are identical
identical differs not published
01

What actually differs

19 of 25 parameters
Parameter MOD 10KTL3-XH SPH 10000TL-HU Difference
Max DC voltage 1100 V 525 V 575 V apart
Max input current per tracker 16.0 A 22.0 A 6.0 A more headroom
Max efficiency 98.6 % 97.5 % 1.1 pp more efficient
Max AC power 11.00 kW 10.00 kW 1.00 kW apart
Max PV power 20.00 kW 15.00 kW 5.00 kW apart
DC/AC ratio 2.00 1.50 0.50 more oversizing headroom
Weight 14.0 kg 48.8 kg 34.8 kg lighter
Weight per kW 1.4 kg/kW 4.9 kg/kW 3.5 kg/kW lighter
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 16.7 A 50.0 A 33.3 A apart
MPP trackers 2 3 1 tracker more
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 150-450 V 140-1000 V vs 150-450 V
Battery voltage 600-950 V 40-60V 600-950 V vs 40-60V
Start voltage 160 V 150 V 10 V earlier start
Strings per tracker 1 2 1 string apart
Dimensions 387x425x178 mm 883x440x254 mm 387x425x178 mm vs 883x440x254 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter MOD 10KTL3-XH SPH 10000TL-HU Difference
AC output
Rated AC power 10.00 kW 10.00 kW Same
Max AC power 11.00 kW 10.00 kW 1.00 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 16.7 A 50.0 A 33.3 A apart
PV input
Max PV power 20.00 kW 15.00 kW 5.00 kW apart
DC/AC ratio 2.00 1.50 +0.50 for MOD 10KTL3-XH
Max DC voltage 1100 V 525 V 575 V apart
MPPT voltage range 140-1000 V 150-450 V 140-1000 V vs 150-450 V
Start voltage 160 V 150 V -10 V for SPH 10000TL-HU
MPP trackers 2 3 +1 trackers for SPH 10000TL-HU
Strings per tracker 1 2 1 string apart
Max input current per tracker 16.0 A 22.0 A +6.0 A for SPH 10000TL-HU
Efficiency
European efficiency 98.1 % - Not published by Growatt
Max efficiency 98.6 % 97.5 % +1.1 pp for MOD 10KTL3-XH
CEC efficiency - 97.0 % Not published by Growatt
Battery
Battery input Yes Yes Same
Battery voltage 600-950 V 40-60V 600-950 V vs 40-60V
Max charge current - 200 A Not published by Growatt
Backup power - 10.0 kW Not published by Growatt
Physical
Weight 14.0 kg 48.8 kg -34.8 kg for MOD 10KTL3-XH
Weight per kW 1.4 kg/kW 4.9 kg/kW -3.5 kg/kW for MOD 10KTL3-XH
Dimensions 387x425x178 mm 883x440x254 mm 387x425x178 mm vs 883x440x254 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural forced-air natural vs forced-air
Noise - 30 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Growatt
Arc fault protection - Yes Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 10KTL3-XH vs SolarEdge SE10000H
11 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 10KTL3-XH vs Growatt MOD 10KTL3-HU
9 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MOD 10KTL3-XH vs Huawei SUN2000-10KTL-M1
10 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.