Growatt SPH 10000TL-HU vs Growatt MOD 10KTL3-XH
VS
The verdict
MOD 10KTL3-XH leads on the differences that matter
The largest is max dc voltage: 575 V apart. 6 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.
See all 19 differencesHow alike are they
6
of 25 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
19 of 25 parameters
What actually differs
Parameter
SPH 10000TL-HU
MOD 10KTL3-XH
Difference
Max DC voltage
525 V
1100 V
575 V apart
Max input current per tracker
22.0 A
16.0 A
6.0 A more headroom
Max efficiency
97.5 %
98.6 %
1.1 pp more efficient
Max AC power
10.00 kW
11.00 kW
1.00 kW apart
Max PV power
15.00 kW
20.00 kW
5.00 kW apart
DC/AC ratio
1.50
2.00
0.50 more oversizing headroom
Weight
48.8 kg
14.0 kg
34.8 kg lighter
Weight per kW
4.9 kg/kW
1.4 kg/kW
3.5 kg/kW lighter
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
50.0 A
16.7 A
33.3 A apart
MPP trackers
3
2
1 tracker more
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
150-450 V
140-1000 V
150-450 V vs 140-1000 V
Battery voltage
40-60V
600-950 V
40-60V vs 600-950 V
Start voltage
150 V
160 V
10 V earlier start
Strings per tracker
2
1
1 string apart
Dimensions
883x440x254 mm
387x425x178 mm
883x440x254 mm vs 387x425x178 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
SPH 10000TL-HU
MOD 10KTL3-XH
Difference
AC output
Rated AC power
10.00 kW
10.00 kW
Same
Max AC power
10.00 kW
11.00 kW
1.00 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
50.0 A
16.7 A
33.3 A apart
PV input
Max PV power
15.00 kW
20.00 kW
5.00 kW apart
DC/AC ratio
1.50
2.00
+0.50 for MOD 10KTL3-XH
Max DC voltage
525 V
1100 V
575 V apart
MPPT voltage range
150-450 V
140-1000 V
150-450 V vs 140-1000 V
Start voltage
150 V
160 V
-10 V for SPH 10000TL-HU
MPP trackers
3
2
+1 trackers for SPH 10000TL-HU
Strings per tracker
2
1
1 string apart
Max input current per tracker
22.0 A
16.0 A
+6.0 A for SPH 10000TL-HU
Efficiency
European efficiency
-
98.1 %
Not published by Growatt
Max efficiency
97.5 %
98.6 %
+1.1 pp for MOD 10KTL3-XH
CEC efficiency
97.0 %
-
Not published by Growatt
Battery
Battery input
Yes
Yes
Same
Battery voltage
40-60V
600-950 V
40-60V vs 600-950 V
Max charge current
200 A
-
Not published by Growatt
Backup power
10.0 kW
-
Not published by Growatt
Physical
Weight
48.8 kg
14.0 kg
-34.8 kg for MOD 10KTL3-XH
Weight per kW
4.9 kg/kW
1.4 kg/kW
-3.5 kg/kW for MOD 10KTL3-XH
Dimensions
883x440x254 mm
387x425x178 mm
883x440x254 mm vs 387x425x178 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
natural
forced-air vs natural
Noise
30 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt SPH 10000TL-HU vs SolarEdge SE10000H
9 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPH 10000TL-HU vs Growatt MOD 10KTL3-HU
19 differences, the largest is warranty
Same type, similar size
Huawei
Growatt SPH 10000TL-HU vs Huawei SUN2000-10KTL-M1
18 differences, the largest is max dc voltage
Same type, similar size
Huawei
Growatt MOD 10KTL3-XH vs Huawei SUN2000-10KTL-M1 (High current version)
10 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.