Skip to main content
SPH 10000TL-HU vs MOD 10KTL3-XH 6 of 25 identical Swap Change inverters

Growatt SPH 10000TL-HU vs Growatt MOD 10KTL3-XH

Growatt SPH 10000TL-HU
Growatt
SPH 10000TL-HU
10 kW Hybrid
VS
Growatt MOD 10KTL3-XH
Growatt
MOD 10KTL3-XH
10 kW 98.1 % euro Hybrid
The verdict

MOD 10KTL3-XH leads on the differences that matter

The largest is max dc voltage: 575 V apart. 6 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.

See all 19 differences
How alike are they
6 of 25 comparable
parameters are identical
identical differs not published
01

What actually differs

19 of 25 parameters
Parameter SPH 10000TL-HU MOD 10KTL3-XH Difference
Max DC voltage 525 V 1100 V 575 V apart
Max input current per tracker 22.0 A 16.0 A 6.0 A more headroom
Max efficiency 97.5 % 98.6 % 1.1 pp more efficient
Max AC power 10.00 kW 11.00 kW 1.00 kW apart
Max PV power 15.00 kW 20.00 kW 5.00 kW apart
DC/AC ratio 1.50 2.00 0.50 more oversizing headroom
Weight 48.8 kg 14.0 kg 34.8 kg lighter
Weight per kW 4.9 kg/kW 1.4 kg/kW 3.5 kg/kW lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 50.0 A 16.7 A 33.3 A apart
MPP trackers 3 2 1 tracker more
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 150-450 V 140-1000 V 150-450 V vs 140-1000 V
Battery voltage 40-60V 600-950 V 40-60V vs 600-950 V
Start voltage 150 V 160 V 10 V earlier start
Strings per tracker 2 1 1 string apart
Dimensions 883x440x254 mm 387x425x178 mm 883x440x254 mm vs 387x425x178 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter SPH 10000TL-HU MOD 10KTL3-XH Difference
AC output
Rated AC power 10.00 kW 10.00 kW Same
Max AC power 10.00 kW 11.00 kW 1.00 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 50.0 A 16.7 A 33.3 A apart
PV input
Max PV power 15.00 kW 20.00 kW 5.00 kW apart
DC/AC ratio 1.50 2.00 +0.50 for MOD 10KTL3-XH
Max DC voltage 525 V 1100 V 575 V apart
MPPT voltage range 150-450 V 140-1000 V 150-450 V vs 140-1000 V
Start voltage 150 V 160 V -10 V for SPH 10000TL-HU
MPP trackers 3 2 +1 trackers for SPH 10000TL-HU
Strings per tracker 2 1 1 string apart
Max input current per tracker 22.0 A 16.0 A +6.0 A for SPH 10000TL-HU
Efficiency
European efficiency - 98.1 % Not published by Growatt
Max efficiency 97.5 % 98.6 % +1.1 pp for MOD 10KTL3-XH
CEC efficiency 97.0 % - Not published by Growatt
Battery
Battery input Yes Yes Same
Battery voltage 40-60V 600-950 V 40-60V vs 600-950 V
Max charge current 200 A - Not published by Growatt
Backup power 10.0 kW - Not published by Growatt
Physical
Weight 48.8 kg 14.0 kg -34.8 kg for MOD 10KTL3-XH
Weight per kW 4.9 kg/kW 1.4 kg/kW -3.5 kg/kW for MOD 10KTL3-XH
Dimensions 883x440x254 mm 387x425x178 mm 883x440x254 mm vs 387x425x178 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air natural forced-air vs natural
Noise 30 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Growatt
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt SPH 10000TL-HU vs SolarEdge SE10000H
9 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPH 10000TL-HU vs Growatt MOD 10KTL3-HU
19 differences, the largest is warranty
Same type, similar size
Huawei
Growatt SPH 10000TL-HU vs Huawei SUN2000-10KTL-M1
18 differences, the largest is max dc voltage
Same type, similar size
Huawei
Growatt MOD 10KTL3-XH vs Huawei SUN2000-10KTL-M1 (High current version)
10 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.