Skip to main content
MOD 10KTL3-XH vs SE10000H 8 of 19 identical Swap Change inverters

Growatt MOD 10KTL3-XH vs SolarEdge SE10000H

Growatt MOD 10KTL3-XH
Growatt
MOD 10KTL3-XH
10 kW 98.1 % euro Hybrid
VS
SolarEdge SE10000H
SolarEdge
SE10000H
10 kW 99.0 % euro Hybrid
The verdict

SE10000H leads on the differences that matter

The largest is european efficiency: 0.9 pp more efficient. 8 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
8 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 19 parameters
Parameter MOD 10KTL3-XH SE10000H Difference
European efficiency 98.1 % 99.0 % 0.9 pp more efficient
Max DC voltage 1100 V 480 V 620 V apart
Max efficiency 98.6 % 99.2 % 0.6 pp more efficient
Max AC power 11.00 kW 10.00 kW 1.00 kW apart
Weight 14.0 kg 19.6 kg 5.6 kg lighter
Weight per kW 1.4 kg/kW 2.0 kg/kW 0.6 kg/kW lighter
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 16.7 A 45.5 A 28.8 A apart
Ingress protection IP66 IP65 IP66 vs IP65
Dimensions 387x425x178 mm 535x370x185 mm 387x425x178 mm vs 535x370x185 mm
02

Full specification

Parameter MOD 10KTL3-XH SE10000H Difference
AC output
Rated AC power 10.00 kW 10.00 kW Same
Max AC power 11.00 kW 10.00 kW 1.00 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 16.7 A 45.5 A 28.8 A apart
PV input
Max PV power 20.00 kW 20.00 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 1100 V 480 V 620 V apart
MPPT voltage range 140-1000 V - Not published by SolarEdge
Start voltage 160 V - Not published by SolarEdge
MPP trackers 2 - Not published by SolarEdge
Strings per tracker 1 - Not published by SolarEdge
Max input current per tracker 16.0 A - Not published by SolarEdge
Efficiency
European efficiency 98.1 % 99.0 % +0.9 pp for SE10000H
Max efficiency 98.6 % 99.2 % +0.6 pp for SE10000H
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-950 V - Not published by SolarEdge
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 14.0 kg 19.6 kg -5.6 kg for MOD 10KTL3-XH
Weight per kW 1.4 kg/kW 2.0 kg/kW -0.6 kg/kW for MOD 10KTL3-XH
Dimensions 387x425x178 mm 535x370x185 mm 387x425x178 mm vs 535x370x185 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection - Yes Not published by Growatt
Integrated DC switch Yes - Not published by SolarEdge
Warranty
Warranty 5 yrs - Not published by SolarEdge
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MOD 10KTL3-XH vs Growatt MOD 10KTL3-HU
9 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MOD 10KTL3-XH vs Huawei SUN2000-10KTL-M1
10 differences, the largest is max input current per tracker