MIN 6000TL-XH2 vs SUN2000-6KTL-L1 15 of 28 identical Swap Change inverters

Growatt MIN 6000TL-XH2 vs Huawei SUN2000-6KTL-L1

Growatt MIN 6000TL-XH2
Growatt
MIN 6000TL-XH2
6 kW 97.5 % euro Hybrid
VS
Huawei SUN2000-6KTL-L1
Huawei
SUN2000-6KTL-L1
6 kW 97.8 % euro Hybrid
The verdict

MIN 6000TL-XH2 leads on the differences that matter

The largest is max dc voltage: 50 V apart. 15 of 28 comparable parameters are identical, with 4 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
15 of 28 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 28 parameters
Parameter MIN 6000TL-XH2 SUN2000-6KTL-L1 Difference
Max DC voltage 550 V 600 V 50 V apart
Max input current per tracker 16.0 A 12.5 A 3.5 A more headroom
Max PV power 10.00 kW 9.00 kW 1.00 kW apart
European efficiency 97.5 % 97.8 % 0.3 pp more efficient
DC/AC ratio 1.67 1.50 0.17 more oversizing headroom
Weight 10.8 kg 12.0 kg 1.2 kg lighter
Start voltage 50 V 100 V 50 V earlier start
Max charge current 17 A 15 A 2 A faster charging
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 40-540 V 90-560 V 40-540 V vs 90-560 V
Battery voltage 360-550 V 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh) 360-550 V vs 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
Weight per kW 1.8 kg/kW 2.0 kg/kW 0.2 kg/kW lighter
Dimensions 350x375x160 mm 365x365x156 mm 350x375x160 mm vs 365x365x156 mm
02

Full specification

Parameter MIN 6000TL-XH2 SUN2000-6KTL-L1 Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.00 kW 6.00 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 27.2 A 27.3 A Effectively the same
PV input
Max PV power 10.00 kW 9.00 kW 1.00 kW apart
DC/AC ratio 1.67 1.50 +0.17 for MIN 6000TL-XH2
Max DC voltage 550 V 600 V 50 V apart
MPPT voltage range 40-540 V 90-560 V 40-540 V vs 90-560 V
Start voltage 50 V 100 V -50 V for MIN 6000TL-XH2
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 16.0 A 12.5 A +3.5 A for MIN 6000TL-XH2
Efficiency
European efficiency 97.5 % 97.8 % +0.3 pp for SUN2000-6KTL-L1
Max efficiency 98.4 % 98.4 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 360-550 V 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh) 360-550 V vs 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
Max charge current 17 A 15 A +2 A for MIN 6000TL-XH2
Backup power - - Neither datasheet publishes this
Physical
Weight 10.8 kg 12.0 kg -1.2 kg for MIN 6000TL-XH2
Weight per kW 1.8 kg/kW 2.0 kg/kW -0.2 kg/kW for MIN 6000TL-XH2
Dimensions 350x375x160 mm 365x365x156 mm 350x375x160 mm vs 365x365x156 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MIN 6000TL-XH2 vs SolarEdge SE6000H
9 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MIN 6000TL-XH2 vs Growatt MOD 6000TL3-HU
17 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MIN 6000TL-XH2 vs Huawei SUN2000-6KTL-M1