Skip to main content
MIN 6000TL-XH2 vs MOD 6000TL3-HU 11 of 28 identical Swap Change inverters

Growatt MIN 6000TL-XH2 vs Growatt MOD 6000TL3-HU

Growatt MIN 6000TL-XH2
Growatt
MIN 6000TL-XH2
6 kW 97.5 % euro Hybrid
VS
Growatt MOD 6000TL3-HU
Growatt
MOD 6000TL3-HU
6 kW 97.8 % euro Hybrid
The verdict

MOD 6000TL3-HU leads on the differences that matter

The largest is warranty: 5 yrs longer. 11 of 28 comparable parameters are identical, with 4 more left out because at least one datasheet does not publish them.

See all 17 differences
How alike are they
11 of 28 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 28 parameters
Parameter MIN 6000TL-XH2 MOD 6000TL3-HU Difference
Warranty 5 yrs 10 yrs 5 yrs longer
Max DC voltage 550 V 1000 V 450 V apart
Max input current per tracker 16.0 A 20.0 A 4.0 A more headroom
Max AC power 6.00 kW 6.60 kW 0.60 kW apart
Max PV power 10.00 kW 12.00 kW 2.00 kW apart
DC/AC ratio 1.67 2.00 0.33 more oversizing headroom
Max charge current 17 A 25 A 8 A faster charging
Weight 10.8 kg 19.0 kg 8.2 kg lighter
Weight per kW 1.8 kg/kW 3.2 kg/kW 1.4 kg/kW lighter
European efficiency 97.5 % 97.8 % 0.3 pp more efficient
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 27.2 A 10.0 A 17.2 A apart
Start voltage 50 V 180 V 130 V earlier start
MPPT voltage range 40-540 V 140-1000 V 40-540 V vs 140-1000 V
Battery voltage 360-550 V 600-980 V 360-550 V vs 600-980 V
Dimensions 350x375x160 mm 468x408x202 mm 350x375x160 mm vs 468x408x202 mm
02

Full specification

Parameter MIN 6000TL-XH2 MOD 6000TL3-HU Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.00 kW 6.60 kW 0.60 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 27.2 A 10.0 A 17.2 A apart
PV input
Max PV power 10.00 kW 12.00 kW 2.00 kW apart
DC/AC ratio 1.67 2.00 +0.33 for MOD 6000TL3-HU
Max DC voltage 550 V 1000 V 450 V apart
MPPT voltage range 40-540 V 140-1000 V 40-540 V vs 140-1000 V
Start voltage 50 V 180 V -130 V for MIN 6000TL-XH2
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 16.0 A 20.0 A +4.0 A for MOD 6000TL3-HU
Efficiency
European efficiency 97.5 % 97.8 % +0.3 pp for MOD 6000TL3-HU
Max efficiency 98.4 % 98.3 % Effectively the same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 360-550 V 600-980 V 360-550 V vs 600-980 V
Max charge current 17 A 25 A +8 A for MOD 6000TL3-HU
Backup power - - Neither datasheet publishes this
Physical
Weight 10.8 kg 19.0 kg -8.2 kg for MIN 6000TL-XH2
Weight per kW 1.8 kg/kW 3.2 kg/kW -1.4 kg/kW for MIN 6000TL-XH2
Dimensions 350x375x160 mm 468x408x202 mm 350x375x160 mm vs 468x408x202 mm
Ingress protection IP66 IP66 Same
Cooling natural natural Same
Noise - 29 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Growatt
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 10 yrs +5 yrs for MOD 6000TL3-HU
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MIN 6000TL-XH2 vs SolarEdge SE6000H
9 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MIN 6000TL-XH2 vs Huawei SUN2000-6KTL-L1
13 differences, the largest is max dc voltage
Same type, similar size
Huawei
Growatt MIN 6000TL-XH2 vs Huawei SUN2000-6KTL-M1
18 differences, the largest is max dc voltage
Same type, similar size
Huawei
Growatt MOD 6000TL3-HU vs Huawei SUN2000-6KTL-M1 (High current version)
13 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.