Skip to main content
MIN 3600TL-X vs S6-GR1P3.6K-M 7 of 23 identical Swap Change inverters

Growatt MIN 3600TL-X vs Ginlong Solis S6-GR1P3.6K-M

Growatt MIN 3600TL-X
Growatt
MIN 3600TL-X
3.6 kW 97.0 % euro Grid-tie
VS
Ginlong Solis S6-GR1P3.6K-M
Ginlong Solis
S6-GR1P3.6K-M
3.6 kW 96.8 % euro Grid-tie
The verdict

S6-GR1P3.6K-M leads on the differences that matter

The largest is max input current per tracker: 6.5 A more headroom. 7 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
7 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 23 parameters
Parameter MIN 3600TL-X S6-GR1P3.6K-M Difference
Max input current per tracker 12.5 A 19.0 A 6.5 A more headroom
Max efficiency 98.2 % 97.3 % 0.9 pp more efficient
Max AC power 3.96 kW 3.60 kW 0.36 kW apart
Weight 10.8 kg 8.1 kg 2.7 kg lighter
Weight per kW 3.0 kg/kW 2.2 kg/kW 0.8 kg/kW lighter
Max PV power 5.04 kW 5.40 kW 0.36 kW apart
European efficiency 97.0 % 96.8 % 0.2 pp more efficient
DC/AC ratio 1.40 1.50 0.10 more oversizing headroom
Start voltage 100 V 60 V 40 V earlier start
MPP trackers 2 1 1 tracker more
Ingress protection IP65 IP66 IP65 vs IP66
Max AC current 17.2 A 16.0 A 1.2 A apart
Nominal AC voltage 220 V 230 V 10 V apart
MPPT voltage range 80-550 V 50-500 V 80-550 V vs 50-500 V
Strings per tracker 1 2 1 string apart
Dimensions 350x375x158 mm 373x310x160 mm 350x375x158 mm vs 373x310x160 mm
02

Full specification

Parameter MIN 3600TL-X S6-GR1P3.6K-M Difference
AC output
Rated AC power 3.60 kW 3.60 kW Same
Max AC power 3.96 kW 3.60 kW 0.36 kW apart
Grid connection Single-phase Single-phase Same
Nominal AC voltage 220 V 230 V 10 V apart
Max AC current 17.2 A 16.0 A 1.2 A apart
PV input
Max PV power 5.04 kW 5.40 kW 0.36 kW apart
DC/AC ratio 1.40 1.50 +0.10 for S6-GR1P3.6K-M
Max DC voltage 550 V 550 V Same
MPPT voltage range 80-550 V 50-500 V 80-550 V vs 50-500 V
Start voltage 100 V 60 V -40 V for S6-GR1P3.6K-M
MPP trackers 2 1 +1 trackers for MIN 3600TL-X
Strings per tracker 1 2 1 string apart
Max input current per tracker 12.5 A 19.0 A +6.5 A for S6-GR1P3.6K-M
Efficiency
European efficiency 97.0 % 96.8 % +0.2 pp for MIN 3600TL-X
Max efficiency 98.2 % 97.3 % +0.9 pp for MIN 3600TL-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 10.8 kg 8.1 kg -2.7 kg for S6-GR1P3.6K-M
Weight per kW 3.0 kg/kW 2.2 kg/kW -0.8 kg/kW for S6-GR1P3.6K-M
Dimensions 350x375x158 mm 373x310x160 mm 350x375x158 mm vs 373x310x160 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - 20 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
Sofar Solar
Growatt MIN 3600TL-X vs SOFAR 3.6KTLM-G3
11 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MIN 3600TL-X vs Ginlong Solis S6-GR1P3.6K-S
13 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Growatt MIN 3600TL-X vs Ginlong Solis S6-GR1P3.6K
12 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.