Ginlong Solis S6-GR1P3.6K-M vs Growatt MIN 3600TL-X
VS
The verdict
S6-GR1P3.6K-M leads on the differences that matter
The largest is max input current per tracker: 6.5 A more headroom. 7 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 16 differencesHow alike are they
7
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 23 parameters
What actually differs
Parameter
S6-GR1P3.6K-M
MIN 3600TL-X
Difference
Max input current per tracker
19.0 A
12.5 A
6.5 A more headroom
Max efficiency
97.3 %
98.2 %
0.9 pp more efficient
Max AC power
3.60 kW
3.96 kW
0.36 kW apart
Weight
8.1 kg
10.8 kg
2.7 kg lighter
Weight per kW
2.2 kg/kW
3.0 kg/kW
0.8 kg/kW lighter
Max PV power
5.40 kW
5.04 kW
0.36 kW apart
European efficiency
96.8 %
97.0 %
0.2 pp more efficient
DC/AC ratio
1.50
1.40
0.10 more oversizing headroom
Start voltage
60 V
100 V
40 V earlier start
MPP trackers
1
2
1 tracker more
Ingress protection
IP66
IP65
IP66 vs IP65
Max AC current
16.0 A
17.2 A
1.2 A apart
Nominal AC voltage
230 V
220 V
10 V apart
MPPT voltage range
50-500 V
80-550 V
50-500 V vs 80-550 V
Strings per tracker
2
1
1 string apart
Dimensions
373x310x160 mm
350x375x158 mm
373x310x160 mm vs 350x375x158 mm
02
Full specification
Parameter
S6-GR1P3.6K-M
MIN 3600TL-X
Difference
AC output
Rated AC power
3.60 kW
3.60 kW
Same
Max AC power
3.60 kW
3.96 kW
0.36 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
220 V
10 V apart
Max AC current
16.0 A
17.2 A
1.2 A apart
PV input
Max PV power
5.40 kW
5.04 kW
0.36 kW apart
DC/AC ratio
1.50
1.40
+0.10 for S6-GR1P3.6K-M
Max DC voltage
550 V
550 V
Same
MPPT voltage range
50-500 V
80-550 V
50-500 V vs 80-550 V
Start voltage
60 V
100 V
-40 V for S6-GR1P3.6K-M
MPP trackers
1
2
+1 trackers for MIN 3600TL-X
Strings per tracker
2
1
1 string apart
Max input current per tracker
19.0 A
12.5 A
+6.5 A for S6-GR1P3.6K-M
Efficiency
European efficiency
96.8 %
97.0 %
+0.2 pp for MIN 3600TL-X
Max efficiency
97.3 %
98.2 %
+0.9 pp for MIN 3600TL-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
8.1 kg
10.8 kg
-2.7 kg for S6-GR1P3.6K-M
Weight per kW
2.2 kg/kW
3.0 kg/kW
-0.8 kg/kW for S6-GR1P3.6K-M
Dimensions
373x310x160 mm
350x375x158 mm
373x310x160 mm vs 350x375x158 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
20 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Sofar Solar
Ginlong Solis S6-GR1P3.6K-M vs SOFAR 3.6KTLM-G3
13 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GR1P3.6K-M vs Ginlong Solis S6-GR1P3.6K-S
9 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GR1P3.6K-M vs Ginlong Solis S6-GR1P3.6K
10 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.