Growatt MIN 3600TL-X vs Ginlong Solis S6-GR1P3.6K
VS
The verdict
12 differences, and they point both ways
The largest is max dc voltage: 50 V apart. 11 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
11
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 23 parameters
What actually differs
Parameter
MIN 3600TL-X
S6-GR1P3.6K
Difference
Max DC voltage
550 V
600 V
50 V apart
Max efficiency
98.2 %
97.3 %
0.9 pp more efficient
European efficiency
97.0 %
96.6 %
0.4 pp more efficient
Max input current per tracker
12.5 A
14.0 A
1.5 A more headroom
Max PV power
5.04 kW
5.40 kW
0.36 kW apart
DC/AC ratio
1.40
1.50
0.10 more oversizing headroom
Start voltage
100 V
60 V
40 V earlier start
Ingress protection
IP65
IP66
IP65 vs IP66
Max AC current
17.2 A
16.0 A
1.2 A apart
Nominal AC voltage
220 V
230 V
10 V apart
MPPT voltage range
80-550 V
50-520 V
80-550 V vs 50-520 V
Dimensions
350x375x158 mm
543x310x160 mm
350x375x158 mm vs 543x310x160 mm
02
Full specification
Parameter
MIN 3600TL-X
S6-GR1P3.6K
Difference
AC output
Rated AC power
3.60 kW
3.60 kW
Same
Max AC power
3.96 kW
4.00 kW
Effectively the same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
220 V
230 V
10 V apart
Max AC current
17.2 A
16.0 A
1.2 A apart
PV input
Max PV power
5.04 kW
5.40 kW
0.36 kW apart
DC/AC ratio
1.40
1.50
+0.10 for S6-GR1P3.6K
Max DC voltage
550 V
600 V
50 V apart
MPPT voltage range
80-550 V
50-520 V
80-550 V vs 50-520 V
Start voltage
100 V
60 V
-40 V for S6-GR1P3.6K
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
12.5 A
14.0 A
+1.5 A for S6-GR1P3.6K
Efficiency
European efficiency
97.0 %
96.6 %
+0.4 pp for MIN 3600TL-X
Max efficiency
98.2 %
97.3 %
+0.9 pp for MIN 3600TL-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
11.2 kg
Effectively the same
Weight per kW
3.0 kg/kW
3.1 kg/kW
Effectively the same
Dimensions
350x375x158 mm
543x310x160 mm
350x375x158 mm vs 543x310x160 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
natural
Same
Noise
-
20 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Sofar Solar
Growatt MIN 3600TL-X vs SOFAR 3.6KTLM-G3
11 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MIN 3600TL-X vs Ginlong Solis S6-GR1P3.6K-S
13 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Growatt MIN 3600TL-X vs Ginlong Solis S6-GR1P3.6K-M
16 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.