Ginlong Solis S6-GR1P3.6K vs Growatt MIN 3600TL-X
VS
The verdict
12 differences, and they point both ways
The largest is max dc voltage: 50 V apart. 11 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
11
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 23 parameters
What actually differs
Parameter
S6-GR1P3.6K
MIN 3600TL-X
Difference
Max DC voltage
600 V
550 V
50 V apart
Max efficiency
97.3 %
98.2 %
0.9 pp more efficient
European efficiency
96.6 %
97.0 %
0.4 pp more efficient
Max input current per tracker
14.0 A
12.5 A
1.5 A more headroom
Max PV power
5.40 kW
5.04 kW
0.36 kW apart
DC/AC ratio
1.50
1.40
0.10 more oversizing headroom
Start voltage
60 V
100 V
40 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
Max AC current
16.0 A
17.2 A
1.2 A apart
Nominal AC voltage
230 V
220 V
10 V apart
MPPT voltage range
50-520 V
80-550 V
50-520 V vs 80-550 V
Dimensions
543x310x160 mm
350x375x158 mm
543x310x160 mm vs 350x375x158 mm
02
Full specification
Parameter
S6-GR1P3.6K
MIN 3600TL-X
Difference
AC output
Rated AC power
3.60 kW
3.60 kW
Same
Max AC power
4.00 kW
3.96 kW
Effectively the same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
220 V
10 V apart
Max AC current
16.0 A
17.2 A
1.2 A apart
PV input
Max PV power
5.40 kW
5.04 kW
0.36 kW apart
DC/AC ratio
1.50
1.40
+0.10 for S6-GR1P3.6K
Max DC voltage
600 V
550 V
50 V apart
MPPT voltage range
50-520 V
80-550 V
50-520 V vs 80-550 V
Start voltage
60 V
100 V
-40 V for S6-GR1P3.6K
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
14.0 A
12.5 A
+1.5 A for S6-GR1P3.6K
Efficiency
European efficiency
96.6 %
97.0 %
+0.4 pp for MIN 3600TL-X
Max efficiency
97.3 %
98.2 %
+0.9 pp for MIN 3600TL-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
11.2 kg
10.8 kg
Effectively the same
Weight per kW
3.1 kg/kW
3.0 kg/kW
Effectively the same
Dimensions
543x310x160 mm
350x375x158 mm
543x310x160 mm vs 350x375x158 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
20 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Sofar Solar
Ginlong Solis S6-GR1P3.6K vs SOFAR 3.6KTLM-G3
10 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GR1P3.6K vs Ginlong Solis S6-GR1P3.6K-S
9 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GR1P3.6K vs Ginlong Solis S6-GR1P3.6K-M
10 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.