Skip to main content
MIN 11400TL-XH-US vs 11.0KW (11.0KVA/11.0KW, 48V) 2 of 19 identical Swap Change inverters

Growatt MIN 11400TL-XH-US vs Easun Power 11.0KW (11.0KVA/11.0KW, 48V)

Growatt MIN 11400TL-XH-US
Growatt
MIN 11400TL-XH-US
11.4 kW Hybrid
VS
Easun Power 11.0KW (11.0KVA/11.0KW, 48V)
Easun Power
11.0KW (11.0KVA/11.0KW, 48V)
11 kW Hybrid
The verdict

17 differences, and they point both ways

The largest is rated ac power: 0.40 kW apart. 2 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 17 differences
How alike are they
2 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 19 parameters
Parameter MIN 11400TL-XH-US 11.0KW (11.0KVA/11.0KW, 48V) Difference
Rated AC power 11.40 kW 11.00 kW 0.40 kW apart
Max DC voltage 600 V 500 V 100 V apart
Max input current per tracker 13.5 A 18.0 A 4.5 A more headroom
Max efficiency 98.5 % 94.0 % 4.5 pp more efficient
Max AC power 11.40 kW 11.00 kW 0.40 kW apart
Max PV power 22.80 kW 11.00 kW 11.80 kW apart
DC/AC ratio 2.00 1.00 1.00 more oversizing headroom
MPP trackers 4 2 2 trackers more
Max charge current 30 A 160 A 130 A faster charging
Weight 20.5 kg 14.8 kg 5.7 kg lighter
Weight per kW 1.8 kg/kW 1.3 kg/kW 0.5 kg/kW lighter
Max operating temperature 60 °C 55 °C 5 °C more heat tolerant
Nominal AC voltage 240 V 230 V 10 V apart
MPPT voltage range 50-550 V 60-500 V 50-550 V vs 60-500 V
Strings per tracker 2 1 1 string apart
Dimensions 638x400x187 mm 122x403x540 mm 638x400x187 mm vs 122x403x540 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter MIN 11400TL-XH-US 11.0KW (11.0KVA/11.0KW, 48V) Difference
AC output
Rated AC power 11.40 kW 11.00 kW 0.40 kW apart
Max AC power 11.40 kW 11.00 kW 0.40 kW apart
Grid connection Single-phase Single-phase Same
Nominal AC voltage 240 V 230 V 10 V apart
Max AC current 48.0 A - Not published by Easun Power
PV input
Max PV power 22.80 kW 11.00 kW 11.80 kW apart
DC/AC ratio 2.00 1.00 +1.00 for MIN 11400TL-XH-US
Max DC voltage 600 V 500 V 100 V apart
MPPT voltage range 50-550 V 60-500 V 50-550 V vs 60-500 V
Start voltage 50 V - Not published by Easun Power
MPP trackers 4 2 +2 trackers for MIN 11400TL-XH-US
Strings per tracker 2 1 1 string apart
Max input current per tracker 13.5 A 18.0 A +4.5 A for 11.0KW (11.0KVA/11.0KW, 48V)
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 98.5 % 94.0 % +4.5 pp for MIN 11400TL-XH-US
CEC efficiency 98.0 % - Not published by Easun Power
Battery
Battery input Yes Yes Same
Battery voltage 360-550 V - Not published by Easun Power
Max charge current 30 A 160 A +130 A for 11.0KW (11.0KVA/11.0KW, 48V)
Backup power 11.4 kW - Not published by Easun Power
Physical
Weight 20.5 kg 14.8 kg -5.7 kg for 11.0KW (11.0KVA/11.0KW, 48V)
Weight per kW 1.8 kg/kW 1.3 kg/kW -0.5 kg/kW for 11.0KW (11.0KVA/11.0KW, 48V)
Dimensions 638x400x187 mm 122x403x540 mm 638x400x187 mm vs 122x403x540 mm
Ingress protection NEMA 4X (IP65) - Not published by Easun Power
Cooling natural forced-air natural vs forced-air
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 55 °C +5 °C for MIN 11400TL-XH-US
Connectivity and safety
Wi-Fi Yes - Not published by Easun Power
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by Easun Power
Integrated DC switch Yes - Not published by Easun Power
Warranty
Warranty 10 yrs - Not published by Easun Power
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MIN 11400TL-XH-US vs Growatt MID 11KTL3-XH
19 differences, the largest is rated ac power
Same type, similar size
Growatt
Growatt MIN 11400TL-XH-US vs Growatt MOD 11KTL3-HU
17 differences, the largest is rated ac power
Same type, similar size
Growatt
Growatt MIN 11400TL-XH-US vs Growatt MID 12KTL3-XH
19 differences, the largest is rated ac power
Same type, similar size
SolarEdge
Easun Power 11.0KW (11.0KVA/11.0KW, 48V) vs SolarEdge SE10000H
11 differences, the largest is rated ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.