Growatt MIN 11400TL-XH-US vs Growatt MID 12KTL3-XH
VS
The verdict
MIN 11400TL-XH-US leads on the differences that matter
The largest is rated ac power: 0.60 kW apart. 7 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.
See all 19 differencesHow alike are they
7
of 26 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
19 of 26 parameters
What actually differs
Parameter
MIN 11400TL-XH-US
MID 12KTL3-XH
Difference
Rated AC power
11.40 kW
12.00 kW
0.60 kW apart
Warranty
10 yrs
5 yrs
5 yrs longer
Max DC voltage
600 V
1100 V
500 V apart
Max input current per tracker
13.5 A
32.0 A
18.5 A more headroom
Max AC power
11.40 kW
12.00 kW
0.60 kW apart
Max PV power
22.80 kW
24.00 kW
1.20 kW apart
Max charge current
30 A
25 A
5 A faster charging
Weight
20.5 kg
31.0 kg
10.5 kg lighter
Weight per kW
1.8 kg/kW
2.6 kg/kW
0.8 kg/kW lighter
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
240 V
400 V
160 V apart
Max AC current
48.0 A
20.0 A
28.0 A apart
Start voltage
50 V
200 V
150 V earlier start
Max efficiency
98.5 %
98.8 %
0.2 pp more efficient
Ingress protection
NEMA 4X (IP65)
IP66
NEMA 4X (IP65) vs IP66
MPPT voltage range
50-550 V
160-1000 V
50-550 V vs 160-1000 V
Battery voltage
360-550 V
600-980 V
360-550 V vs 600-980 V
Dimensions
638x400x187 mm
435x580x230 mm
638x400x187 mm vs 435x580x230 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MIN 11400TL-XH-US
MID 12KTL3-XH
Difference
AC output
Rated AC power
11.40 kW
12.00 kW
0.60 kW apart
Max AC power
11.40 kW
12.00 kW
0.60 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
240 V
400 V
160 V apart
Max AC current
48.0 A
20.0 A
28.0 A apart
PV input
Max PV power
22.80 kW
24.00 kW
1.20 kW apart
DC/AC ratio
2.00
2.00
Same
Max DC voltage
600 V
1100 V
500 V apart
MPPT voltage range
50-550 V
160-1000 V
50-550 V vs 160-1000 V
Start voltage
50 V
200 V
-150 V for MIN 11400TL-XH-US
MPP trackers
4
-
Not published by Growatt
Strings per tracker
2
2
Same
Max input current per tracker
13.5 A
32.0 A
+18.5 A for MID 12KTL3-XH
Efficiency
European efficiency
-
98.5 %
Not published by Growatt
Max efficiency
98.5 %
98.8 %
+0.2 pp for MID 12KTL3-XH
CEC efficiency
98.0 %
-
Not published by Growatt
Battery
Battery input
Yes
Yes
Same
Battery voltage
360-550 V
600-980 V
360-550 V vs 600-980 V
Max charge current
30 A
25 A
+5 A for MIN 11400TL-XH-US
Backup power
11.4 kW
-
Not published by Growatt
Physical
Weight
20.5 kg
31.0 kg
-10.5 kg for MIN 11400TL-XH-US
Weight per kW
1.8 kg/kW
2.6 kg/kW
-0.8 kg/kW for MIN 11400TL-XH-US
Dimensions
638x400x187 mm
435x580x230 mm
638x400x187 mm vs 435x580x230 mm
Ingress protection
NEMA 4X (IP65)
IP66
NEMA 4X (IP65) vs IP66
Cooling
natural
forced-air
natural vs forced-air
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
10 yrs
5 yrs
+5 yrs for MIN 11400TL-XH-US
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 11400TL-XH-US vs Growatt MID 11KTL3-XH
19 differences, the largest is rated ac power
Same type, similar size
Growatt
Growatt MIN 11400TL-XH-US vs Growatt MOD 11KTL3-HU
17 differences, the largest is rated ac power
Same type, similar size
Easun Power
Growatt MIN 11400TL-XH-US vs Easun Power 11.0KW (11.0KVA/11.0KW, 48V)
17 differences, the largest is rated ac power
Same type, similar size
Huawei
Growatt MID 12KTL3-XH vs Huawei SUN5000-12K-MAP0
12 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Growatt MID 12KTL3-XH vs Huawei SUN2000-12KTL-M1 (High current version)
14 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Growatt MID 12KTL3-XH vs Huawei SUN2000-12K-MAP0
12 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.