Skip to main content
11.0KW (11.0KVA/11.0KW, 48V) vs MIN 11400TL-XH-US 2 of 19 identical Swap Change inverters

Easun Power 11.0KW (11.0KVA/11.0KW, 48V) vs Growatt MIN 11400TL-XH-US

Easun Power 11.0KW (11.0KVA/11.0KW, 48V)
Easun Power
11.0KW (11.0KVA/11.0KW, 48V)
11 kW Hybrid
VS
Growatt MIN 11400TL-XH-US
Growatt
MIN 11400TL-XH-US
11.4 kW Hybrid
The verdict

17 differences, and they point both ways

The largest is rated ac power: 0.40 kW apart. 2 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 17 differences
How alike are they
2 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 19 parameters
Parameter 11.0KW (11.0KVA/11.0KW, 48V) MIN 11400TL-XH-US Difference
Rated AC power 11.00 kW 11.40 kW 0.40 kW apart
Max DC voltage 500 V 600 V 100 V apart
Max input current per tracker 18.0 A 13.5 A 4.5 A more headroom
Max efficiency 94.0 % 98.5 % 4.5 pp more efficient
Max AC power 11.00 kW 11.40 kW 0.40 kW apart
Max PV power 11.00 kW 22.80 kW 11.80 kW apart
DC/AC ratio 1.00 2.00 1.00 more oversizing headroom
MPP trackers 2 4 2 trackers more
Max charge current 160 A 30 A 130 A faster charging
Weight 14.8 kg 20.5 kg 5.7 kg lighter
Weight per kW 1.3 kg/kW 1.8 kg/kW 0.5 kg/kW lighter
Max operating temperature 55 °C 60 °C 5 °C more heat tolerant
Nominal AC voltage 230 V 240 V 10 V apart
MPPT voltage range 60-500 V 50-550 V 60-500 V vs 50-550 V
Strings per tracker 1 2 1 string apart
Dimensions 122x403x540 mm 638x400x187 mm 122x403x540 mm vs 638x400x187 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter 11.0KW (11.0KVA/11.0KW, 48V) MIN 11400TL-XH-US Difference
AC output
Rated AC power 11.00 kW 11.40 kW 0.40 kW apart
Max AC power 11.00 kW 11.40 kW 0.40 kW apart
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 240 V 10 V apart
Max AC current - 48.0 A Not published by Easun Power
PV input
Max PV power 11.00 kW 22.80 kW 11.80 kW apart
DC/AC ratio 1.00 2.00 +1.00 for MIN 11400TL-XH-US
Max DC voltage 500 V 600 V 100 V apart
MPPT voltage range 60-500 V 50-550 V 60-500 V vs 50-550 V
Start voltage - 50 V Not published by Easun Power
MPP trackers 2 4 +2 trackers for MIN 11400TL-XH-US
Strings per tracker 1 2 1 string apart
Max input current per tracker 18.0 A 13.5 A +4.5 A for 11.0KW (11.0KVA/11.0KW, 48V)
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 94.0 % 98.5 % +4.5 pp for MIN 11400TL-XH-US
CEC efficiency - 98.0 % Not published by Easun Power
Battery
Battery input Yes Yes Same
Battery voltage - 360-550 V Not published by Easun Power
Max charge current 160 A 30 A +130 A for 11.0KW (11.0KVA/11.0KW, 48V)
Backup power - 11.4 kW Not published by Easun Power
Physical
Weight 14.8 kg 20.5 kg -5.7 kg for 11.0KW (11.0KVA/11.0KW, 48V)
Weight per kW 1.3 kg/kW 1.8 kg/kW -0.5 kg/kW for 11.0KW (11.0KVA/11.0KW, 48V)
Dimensions 122x403x540 mm 638x400x187 mm 122x403x540 mm vs 638x400x187 mm
Ingress protection - NEMA 4X (IP65) Not published by Easun Power
Cooling forced-air natural forced-air vs natural
Noise - - Neither datasheet publishes this
Max operating temperature 55 °C 60 °C +5 °C for MIN 11400TL-XH-US
Connectivity and safety
Wi-Fi - Yes Not published by Easun Power
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Easun Power
Integrated DC switch - Yes Not published by Easun Power
Warranty
Warranty - 10 yrs Not published by Easun Power
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Easun Power 11.0KW (11.0KVA/11.0KW, 48V) vs Growatt MID 11KTL3-XH
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Easun Power 11.0KW (11.0KVA/11.0KW, 48V) vs Growatt MOD 11KTL3-HU
15 differences, the largest is max dc voltage
Same type, similar size
SolarEdge
Easun Power 11.0KW (11.0KVA/11.0KW, 48V) vs SolarEdge SE10000H
11 differences, the largest is rated ac power
Same type, similar size
Growatt
Growatt MIN 11400TL-XH-US vs Growatt MID 12KTL3-XH
19 differences, the largest is rated ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.