Skip to main content
MIN 10000TL-XH-US vs MOD 10KTL3-HU 12 of 27 identical Swap Change inverters

Growatt MIN 10000TL-XH-US vs Growatt MOD 10KTL3-HU

Growatt MIN 10000TL-XH-US
Growatt
MIN 10000TL-XH-US
10 kW Hybrid
VS
Growatt MOD 10KTL3-HU
Growatt
MOD 10KTL3-HU
10 kW 98.1 % euro Hybrid
The verdict

15 differences, and they point both ways

The largest is max dc voltage: 400 V apart. 12 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
12 of 27 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 27 parameters
Parameter MIN 10000TL-XH-US MOD 10KTL3-HU Difference
Max DC voltage 600 V 1000 V 400 V apart
Max input current per tracker 13.5 A 20.0 A 6.5 A more headroom
Max charge current 30 A 25 A 5 A faster charging
Max efficiency 98.3 % 98.6 % 0.3 pp more efficient
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 240 V 400 V 160 V apart
Max AC current 42.0 A 16.7 A 25.3 A apart
Start voltage 50 V 160 V 110 V earlier start
MPP trackers 4 3 1 tracker more
Ingress protection NEMA 4X (IP65) IP66 NEMA 4X (IP65) vs IP66
MPPT voltage range 50-550 V 140-1000 V 50-550 V vs 140-1000 V
Battery voltage 360-550 V 600-980V 360-550 V vs 600-980V
Weight 20.5 kg 20.0 kg 0.5 kg lighter
Strings per tracker 2 1 1 string apart
Dimensions 638x400x187 mm 480x468x202 mm 638x400x187 mm vs 480x468x202 mm
02

Full specification

Parameter MIN 10000TL-XH-US MOD 10KTL3-HU Difference
AC output
Rated AC power 10.00 kW 10.00 kW Same
Max AC power 10.00 kW 10.00 kW Same
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 240 V 400 V 160 V apart
Max AC current 42.0 A 16.7 A 25.3 A apart
PV input
Max PV power 20.00 kW 20.00 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 600 V 1000 V 400 V apart
MPPT voltage range 50-550 V 140-1000 V 50-550 V vs 140-1000 V
Start voltage 50 V 160 V -110 V for MIN 10000TL-XH-US
MPP trackers 4 3 +1 trackers for MIN 10000TL-XH-US
Strings per tracker 2 1 1 string apart
Max input current per tracker 13.5 A 20.0 A +6.5 A for MOD 10KTL3-HU
Efficiency
European efficiency - 98.1 % Not published by Growatt
Max efficiency 98.3 % 98.6 % +0.3 pp for MOD 10KTL3-HU
CEC efficiency 97.5 % - Not published by Growatt
Battery
Battery input Yes Yes Same
Battery voltage 360-550 V 600-980V 360-550 V vs 600-980V
Max charge current 30 A 25 A +5 A for MIN 10000TL-XH-US
Backup power 11.4 kW - Not published by Growatt
Physical
Weight 20.5 kg 20.0 kg -0.5 kg for MOD 10KTL3-HU
Weight per kW 2.0 kg/kW 2.0 kg/kW Same
Dimensions 638x400x187 mm 480x468x202 mm 638x400x187 mm vs 480x468x202 mm
Ingress protection NEMA 4X (IP65) IP66 NEMA 4X (IP65) vs IP66
Cooling natural natural Same
Noise - 29 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty 10 yrs 10 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MIN 10000TL-XH-US vs SolarEdge SE10000H
7 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MIN 10000TL-XH-US vs Growatt MOD 10KTL3-XH
17 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MIN 10000TL-XH-US vs Huawei SUN2000-10KTL-M1
20 differences, the largest is max dc voltage
Same type, similar size
Huawei
Growatt MOD 10KTL3-HU vs Huawei SUN2000-10KTL-M1 (High current version)
14 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.