Growatt MID 40K-HU vs Growatt WIT 40K-A-US L2 / WIT 40K-AU-US L2
VS
The verdict
MID 40K-HU leads on the differences that matter
The largest is max efficiency: 0.6 pp more efficient. 4 of 12 comparable parameters are identical, with 20 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
4
of 12 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 12 parameters
What actually differs
Parameter
MID 40K-HU
WIT 40K-A-US L2 / WIT 40K-AU-US L2
Difference
Max efficiency
98.6 %
98.0 %
0.6 pp more efficient
Max AC power
40.00 kW
44.00 kW
4.00 kW apart
Weight
48.0 kg
120.0 kg
72.0 kg lighter
Weight per kW
1.2 kg/kW
3.0 kg/kW
1.8 kg/kW lighter
Max AC current
66.7 A
122.2 A
55.5 A apart
Ingress protection
IP66
IP66/NEMA 4X
IP66 vs IP66/NEMA 4X
Battery voltage
600-980 V
380~450V
600-980 V vs 380~450V
Dimensions
570x680x256 mm
820x1350x501 mm
570x680x256 mm vs 820x1350x501 mm
02
Full specification
Parameter
MID 40K-HU
WIT 40K-A-US L2 / WIT 40K-AU-US L2
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
40.00 kW
44.00 kW
4.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
-
Not published by Growatt
Max AC current
66.7 A
122.2 A
55.5 A apart
PV input
Max PV power
80.00 kW
-
Not published by Growatt
DC/AC ratio
2.00
-
Not published by Growatt
Max DC voltage
1000 V
-
Not published by Growatt
MPPT voltage range
200-1000 V
-
Not published by Growatt
Start voltage
160 V
-
Not published by Growatt
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
-
Not published by Growatt
Max input current per tracker
40.0 A
-
Not published by Growatt
Efficiency
European efficiency
97.2 %
-
Not published by Growatt
Max efficiency
98.6 %
98.0 %
+0.6 pp for MID 40K-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
380~450V
600-980 V vs 380~450V
Max charge current
42 A
-
Not published by Growatt
Backup power
30.0 kW
-
Not published by Growatt
Physical
Weight
48.0 kg
120.0 kg
-72.0 kg for MID 40K-HU
Weight per kW
1.2 kg/kW
3.0 kg/kW
-1.8 kg/kW for MID 40K-HU
Dimensions
570x680x256 mm
820x1350x501 mm
570x680x256 mm vs 820x1350x501 mm
Ingress protection
IP66
IP66/NEMA 4X
IP66 vs IP66/NEMA 4X
Cooling
forced-air
-
Not published by Growatt
Noise
55 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Growatt
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
5 yrs
-
Not published by Growatt
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Growatt MID 40K-HU vs GoodWe GW40K-ET-10
13 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MID 40K-HU vs Ginlong Solis S6-EH3P40K-H
10 differences, the largest is max efficiency
Same type, similar size
Deye
Growatt MID 40K-HU vs Deye SUN-40K-SG01HP3-EU-BM4
15 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.