Skip to main content
MID 40K-HU vs S6-EH3P40K-H 14 of 24 identical Swap Change inverters

Growatt MID 40K-HU vs Ginlong Solis S6-EH3P40K-H

Growatt MID 40K-HU
Growatt
MID 40K-HU
40 kW 97.2 % euro Hybrid
VS
Ginlong Solis S6-EH3P40K-H
Ginlong Solis
S6-EH3P40K-H
40 kW 97.4 % euro Hybrid
The verdict

MID 40K-HU leads on the differences that matter

The largest is max efficiency: 0.8 pp more efficient. 14 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.

See all 10 differences
How alike are they
14 of 24 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 24 parameters
Parameter MID 40K-HU S6-EH3P40K-H Difference
Max efficiency 98.6 % 97.8 % 0.8 pp more efficient
Max charge current 42 A 140 A 98 A faster charging
Weight 48.0 kg 73.0 kg 25.0 kg lighter
Weight per kW 1.2 kg/kW 1.8 kg/kW 0.6 kg/kW lighter
European efficiency 97.2 % 97.4 % 0.2 pp more efficient
Max AC current 66.7 A 60.8 A 5.9 A apart
MPPT voltage range 200-1000 V 150-850 V 200-1000 V vs 150-850 V
Start voltage 160 V 180 V 20 V earlier start
Battery voltage 600-980 V 150-800 V 600-980 V vs 150-800 V
Dimensions 570x680x256 mm 880x530x290 mm 570x680x256 mm vs 880x530x290 mm
02

Full specification

Parameter MID 40K-HU S6-EH3P40K-H Difference
AC output
Rated AC power 40.00 kW 40.00 kW Same
Max AC power 40.00 kW 40.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 66.7 A 60.8 A 5.9 A apart
PV input
Max PV power 80.00 kW 80.00 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 1000 V 1000 V Same
MPPT voltage range 200-1000 V 150-850 V 200-1000 V vs 150-850 V
Start voltage 160 V 180 V -20 V for MID 40K-HU
MPP trackers - - Neither datasheet publishes this
Strings per tracker 2 2 Same
Max input current per tracker 40.0 A 40.0 A Same
Efficiency
European efficiency 97.2 % 97.4 % +0.2 pp for S6-EH3P40K-H
Max efficiency 98.6 % 97.8 % +0.8 pp for MID 40K-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 150-800 V 600-980 V vs 150-800 V
Max charge current 42 A 140 A +98 A for S6-EH3P40K-H
Backup power 30.0 kW - Not published by Ginlong Solis
Physical
Weight 48.0 kg 73.0 kg -25.0 kg for MID 40K-HU
Weight per kW 1.2 kg/kW 1.8 kg/kW -0.6 kg/kW for MID 40K-HU
Dimensions 570x680x256 mm 880x530x290 mm 570x680x256 mm vs 880x530x290 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise 55 dB - Not published by Ginlong Solis
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Ginlong Solis
Ethernet - Yes Not published by Growatt
Arc fault protection Yes - Not published by Ginlong Solis
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
Growatt MID 40K-HU vs GoodWe GW40K-ET-10
13 differences, the largest is european efficiency
Same type, similar size
Deye
Growatt MID 40K-HU vs Deye SUN-40K-SG01HP3-EU-BM4
15 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MID 40K-HU vs Growatt WT 40K-H-US L2 / WT 40K-HU-US L2
13 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.