Growatt WIT 40K-A-US L2 / WIT 40K-AU-US L2 vs Growatt MID 40K-HU
VS
The verdict
MID 40K-HU leads on the differences that matter
The largest is max efficiency: 0.6 pp more efficient. 4 of 12 comparable parameters are identical, with 20 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
4
of 12 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 12 parameters
What actually differs
Parameter
WIT 40K-A-US L2 / WIT 40K-AU-US L2
MID 40K-HU
Difference
Max efficiency
98.0 %
98.6 %
0.6 pp more efficient
Max AC power
44.00 kW
40.00 kW
4.00 kW apart
Weight
120.0 kg
48.0 kg
72.0 kg lighter
Weight per kW
3.0 kg/kW
1.2 kg/kW
1.8 kg/kW lighter
Max AC current
122.2 A
66.7 A
55.5 A apart
Ingress protection
IP66/NEMA 4X
IP66
IP66/NEMA 4X vs IP66
Battery voltage
380~450V
600-980 V
380~450V vs 600-980 V
Dimensions
820x1350x501 mm
570x680x256 mm
820x1350x501 mm vs 570x680x256 mm
02
Full specification
Parameter
WIT 40K-A-US L2 / WIT 40K-AU-US L2
MID 40K-HU
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
44.00 kW
40.00 kW
4.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
-
400 V
Not published by Growatt
Max AC current
122.2 A
66.7 A
55.5 A apart
PV input
Max PV power
-
80.00 kW
Not published by Growatt
DC/AC ratio
-
2.00
Not published by Growatt
Max DC voltage
-
1000 V
Not published by Growatt
MPPT voltage range
-
200-1000 V
Not published by Growatt
Start voltage
-
160 V
Not published by Growatt
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
2
Not published by Growatt
Max input current per tracker
-
40.0 A
Not published by Growatt
Efficiency
European efficiency
-
97.2 %
Not published by Growatt
Max efficiency
98.0 %
98.6 %
+0.6 pp for MID 40K-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
380~450V
600-980 V
380~450V vs 600-980 V
Max charge current
-
42 A
Not published by Growatt
Backup power
-
30.0 kW
Not published by Growatt
Physical
Weight
120.0 kg
48.0 kg
-72.0 kg for MID 40K-HU
Weight per kW
3.0 kg/kW
1.2 kg/kW
-1.8 kg/kW for MID 40K-HU
Dimensions
820x1350x501 mm
570x680x256 mm
820x1350x501 mm vs 570x680x256 mm
Ingress protection
IP66/NEMA 4X
IP66
IP66/NEMA 4X vs IP66
Cooling
-
forced-air
Not published by Growatt
Noise
-
55 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Growatt
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
-
5 yrs
Not published by Growatt
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Growatt WIT 40K-A-US L2 / WIT 40K-AU-US L2 vs GoodWe GW40K-ET-10
6 differences, the largest is weight
Same type, similar size
Ginlong Solis
Growatt WIT 40K-A-US L2 / WIT 40K-AU-US L2 vs Ginlong Solis S6-EH3P40K-H
8 differences, the largest is max ac power
Same type, similar size
Deye
Growatt WIT 40K-A-US L2 / WIT 40K-AU-US L2 vs Deye SUN-40K-SG01HP3-EU-BM4
7 differences, the largest is weight
Same type, similar size
Growatt
Growatt MID 40K-HU vs Growatt WT 40K-H-US L2 / WT 40K-HU-US L2
13 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.