Growatt MID 29.9K-HU vs Deye SUN-29.9K-SG01HP3-EU-BM3
VS
The verdict
MID 29.9K-HU leads on the differences that matter
The largest is max input current per tracker: 4.0 A more headroom. 11 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
11
of 25 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 25 parameters
What actually differs
Parameter
MID 29.9K-HU
SUN-29.9K-SG01HP3-EU-BM3
Difference
Max input current per tracker
40.0 A
36.0 A
4.0 A more headroom
Max efficiency
98.6 %
97.6 %
1.0 pp more efficient
Max PV power
59.80 kW
38.87 kW
20.93 kW apart
DC/AC ratio
2.00
1.30
0.70 more oversizing headroom
Max charge current
42 A
100 A
58 A faster charging
Weight
48.0 kg
80.0 kg
32.0 kg lighter
Weight per kW
1.6 kg/kW
2.7 kg/kW
1.1 kg/kW lighter
Noise
55 dB
65 dB
10 dB quieter
European efficiency
97.2 %
97.0 %
0.2 pp more efficient
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
200-1000 V
150-850 V
200-1000 V vs 150-850 V
Start voltage
160 V
180 V
20 V earlier start
Battery voltage
600-980 V
160-800
600-980 V vs 160-800
Dimensions
570x680x256 mm
894x527x294 mm
570x680x256 mm vs 894x527x294 mm
02
Full specification
Parameter
MID 29.9K-HU
SUN-29.9K-SG01HP3-EU-BM3
Difference
AC output
Rated AC power
29.90 kW
29.90 kW
Same
Max AC power
29.90 kW
29.90 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
45.3 A
45.4 A
Effectively the same
PV input
Max PV power
59.80 kW
38.87 kW
20.93 kW apart
DC/AC ratio
2.00
1.30
+0.70 for MID 29.9K-HU
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
200-1000 V
150-850 V
200-1000 V vs 150-850 V
Start voltage
160 V
180 V
-20 V for MID 29.9K-HU
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
36.0 A
+4.0 A for MID 29.9K-HU
Efficiency
European efficiency
97.2 %
97.0 %
+0.2 pp for MID 29.9K-HU
Max efficiency
98.6 %
97.6 %
+1.0 pp for MID 29.9K-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
160-800
600-980 V vs 160-800
Max charge current
42 A
100 A
+58 A for SUN-29.9K-SG01HP3-EU-BM3
Backup power
30.0 kW
-
Not published by Deye
Physical
Weight
48.0 kg
80.0 kg
-32.0 kg for MID 29.9K-HU
Weight per kW
1.6 kg/kW
2.7 kg/kW
-1.1 kg/kW for MID 29.9K-HU
Dimensions
570x680x256 mm
894x527x294 mm
570x680x256 mm vs 894x527x294 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
forced-air
Same
Noise
55 dB
65 dB
-10 dB for MID 29.9K-HU
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Deye
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Deye
Integrated DC switch
Yes
-
Not published by Deye
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MID 29.9K-HU vs Growatt WIT 29.9K-XHU
9 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Growatt MID 29.9K-HU vs Fronius Verto 30.0 Plus
13 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MID 29.9K-HU vs Ginlong Solis S6-EH3P30K-H
12 differences, the largest is max efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.