Ginlong Solis S6-EH3P30K-H vs Growatt MID 29.9K-HU
VS
The verdict
MID 29.9K-HU leads on the differences that matter
The largest is max efficiency: 0.8 pp more efficient. 12 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
12
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 24 parameters
What actually differs
Parameter
S6-EH3P30K-H
MID 29.9K-HU
Difference
Max efficiency
97.8 %
98.6 %
0.8 pp more efficient
Rated AC power
30.00 kW
29.90 kW
0.10 kW apart
Max charge current
140 A
42 A
98 A faster charging
Weight
73.0 kg
48.0 kg
25.0 kg lighter
Weight per kW
2.4 kg/kW
1.6 kg/kW
0.8 kg/kW lighter
European efficiency
97.4 %
97.2 %
0.2 pp more efficient
Max AC power
30.00 kW
29.90 kW
0.10 kW apart
Max PV power
60.00 kW
59.80 kW
0.20 kW apart
MPPT voltage range
150-850 V
200-1000 V
150-850 V vs 200-1000 V
Start voltage
180 V
160 V
20 V earlier start
Battery voltage
150-800 V
600-980 V
150-800 V vs 600-980 V
Dimensions
880x530x290 mm
570x680x256 mm
880x530x290 mm vs 570x680x256 mm
02
Full specification
Parameter
S6-EH3P30K-H
MID 29.9K-HU
Difference
AC output
Rated AC power
30.00 kW
29.90 kW
0.10 kW apart
Max AC power
30.00 kW
29.90 kW
0.10 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
45.6 A
45.3 A
Effectively the same
PV input
Max PV power
60.00 kW
59.80 kW
0.20 kW apart
DC/AC ratio
2.00
2.00
Same
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
150-850 V
200-1000 V
150-850 V vs 200-1000 V
Start voltage
180 V
160 V
-20 V for MID 29.9K-HU
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
40.0 A
Same
Efficiency
European efficiency
97.4 %
97.2 %
+0.2 pp for S6-EH3P30K-H
Max efficiency
97.8 %
98.6 %
+0.8 pp for MID 29.9K-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
150-800 V
600-980 V
150-800 V vs 600-980 V
Max charge current
140 A
42 A
+98 A for S6-EH3P30K-H
Backup power
-
30.0 kW
Not published by Ginlong Solis
Physical
Weight
73.0 kg
48.0 kg
-25.0 kg for MID 29.9K-HU
Weight per kW
2.4 kg/kW
1.6 kg/kW
-0.8 kg/kW for MID 29.9K-HU
Dimensions
880x530x290 mm
570x680x256 mm
880x530x290 mm vs 570x680x256 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
55 dB
Not published by Ginlong Solis
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Ginlong Solis
Ethernet
Yes
-
Not published by Growatt
Arc fault protection
-
Yes
Not published by Ginlong Solis
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Ginlong Solis S6-EH3P30K-H vs Growatt MID 30K-HU
10 differences, the largest is max efficiency
Same type, similar size
Deye
Ginlong Solis S6-EH3P30K-H vs Deye SUN-30K-SG01HP3-EU-BM3
13 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Ginlong Solis S6-EH3P30K-H vs Ginlong Solis S6-EH3P30K-H-LV
4 differences, the largest is european efficiency
Same type, similar size
Deye
Growatt MID 29.9K-HU vs Deye SUN-29.9K-SG01HP3-EU-BM3
14 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MID 29.9K-HU vs Growatt WIT 29.9K-XHU
9 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Growatt MID 29.9K-HU vs Fronius Verto 30.0 Plus
13 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.