Skip to main content
4KVA (PVmax=500V, 48V battery) vs SPM 4000TL-HU 5 of 17 identical Swap Change inverters

Easun Power 4KVA (PVmax=500V, 48V battery) vs Growatt SPM 4000TL-HU

Easun Power 4KVA (PVmax=500V, 48V battery)
Easun Power
4KVA (PVmax=500V, 48V battery)
4 kW Hybrid
VS
Growatt SPM 4000TL-HU
Growatt
SPM 4000TL-HU
4 kW 97.6 % euro Hybrid
The verdict

SPM 4000TL-HU leads on the differences that matter

The largest is max dc voltage: 100 V apart. 5 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
5 of 17 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 17 parameters
Parameter 4KVA (PVmax=500V, 48V battery) SPM 4000TL-HU Difference
Max DC voltage 500 V 600 V 100 V apart
Max efficiency 94.0 % 98.1 % 4.1 pp more efficient
Max PV power 4.00 kW 6.00 kW 2.00 kW apart
DC/AC ratio 1.00 1.50 0.50 more oversizing headroom
Max charge current 120 A 140 A 20 A faster charging
Weight 8.2 kg 26.0 kg 17.8 kg lighter
Weight per kW 2.0 kg/kW 6.5 kg/kW 4.5 kg/kW lighter
Max operating temperature 55 °C 60 °C 5 °C more heat tolerant
MPPT voltage range 60-500 V 150-550 V 60-500 V vs 150-550 V
Battery voltage Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) 40-60V Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) vs 40-60V
Dimensions 105x295x438 mm 330x580x230 mm 105x295x438 mm vs 330x580x230 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter 4KVA (PVmax=500V, 48V battery) SPM 4000TL-HU Difference
AC output
Rated AC power 4.00 kW 4.00 kW Same
Max AC power 4.00 kW 4.00 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current - 17.4 A Not published by Easun Power
PV input
Max PV power 4.00 kW 6.00 kW 2.00 kW apart
DC/AC ratio 1.00 1.50 +0.50 for SPM 4000TL-HU
Max DC voltage 500 V 600 V 100 V apart
MPPT voltage range 60-500 V 150-550 V 60-500 V vs 150-550 V
Start voltage - 130 V Not published by Easun Power
MPP trackers - 2 Not published by Easun Power
Strings per tracker - 1 Not published by Easun Power
Max input current per tracker - 22.0 A Not published by Easun Power
Efficiency
European efficiency - 97.6 % Not published by Easun Power
Max efficiency 94.0 % 98.1 % +4.1 pp for SPM 4000TL-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) 40-60V Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) vs 40-60V
Max charge current 120 A 140 A +20 A for SPM 4000TL-HU
Backup power - - Neither datasheet publishes this
Physical
Weight 8.2 kg 26.0 kg -17.8 kg for 4KVA (PVmax=500V, 48V battery)
Weight per kW 2.0 kg/kW 6.5 kg/kW -4.5 kg/kW for 4KVA (PVmax=500V, 48V battery)
Dimensions 105x295x438 mm 330x580x230 mm 105x295x438 mm vs 330x580x230 mm
Ingress protection - IP65 Not published by Easun Power
Cooling forced-air natural forced-air vs natural
Noise - 30 dB Not published by Easun Power
Max operating temperature 55 °C 60 °C +5 °C for SPM 4000TL-HU
Connectivity and safety
Wi-Fi - Yes Not published by Easun Power
Ethernet - Yes Not published by Easun Power
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - 5 yrs Not published by Easun Power
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Easun Power 4KVA (PVmax=500V, 48V battery) vs SolarEdge SE4000H
9 differences, the largest is max efficiency
Same type, similar size
Huawei
Easun Power 4KVA (PVmax=500V, 48V battery) vs Huawei SUN2000L-4KTL
11 differences, the largest is max dc voltage
Same type, similar size
Growatt
Easun Power 4KVA (PVmax=500V, 48V battery) vs Growatt MOD 4000TL3-HU
15 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPM 4000TL-HU vs Growatt MOD 4000TL3-XH
16 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.