Easun Power 4KVA (PVmax=500V, 48V battery) vs Growatt MOD 4000TL3-HU
VS
The verdict
15 differences, and they point both ways
The largest is max dc voltage: 500 V apart. 2 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
2
of 17 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 17 parameters
What actually differs
Parameter
4KVA (PVmax=500V, 48V battery)
MOD 4000TL3-HU
Difference
Max DC voltage
500 V
1000 V
500 V apart
Max efficiency
94.0 %
98.3 %
4.3 pp more efficient
Max AC power
4.00 kW
4.40 kW
0.40 kW apart
Max PV power
4.00 kW
8.00 kW
4.00 kW apart
DC/AC ratio
1.00
2.00
1.00 more oversizing headroom
Max charge current
120 A
25 A
95 A faster charging
Weight
8.2 kg
19.0 kg
10.8 kg lighter
Weight per kW
2.0 kg/kW
4.8 kg/kW
2.7 kg/kW lighter
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max operating temperature
55 °C
60 °C
5 °C more heat tolerant
MPPT voltage range
60-500 V
140-1000 V
60-500 V vs 140-1000 V
Battery voltage
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA)
600-980 V
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) vs 600-980 V
Dimensions
105x295x438 mm
468x408x202 mm
105x295x438 mm vs 468x408x202 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
4KVA (PVmax=500V, 48V battery)
MOD 4000TL3-HU
Difference
AC output
Rated AC power
4.00 kW
4.00 kW
Same
Max AC power
4.00 kW
4.40 kW
0.40 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
-
6.7 A
Not published by Easun Power
PV input
Max PV power
4.00 kW
8.00 kW
4.00 kW apart
DC/AC ratio
1.00
2.00
+1.00 for MOD 4000TL3-HU
Max DC voltage
500 V
1000 V
500 V apart
MPPT voltage range
60-500 V
140-1000 V
60-500 V vs 140-1000 V
Start voltage
-
180 V
Not published by Easun Power
MPP trackers
-
2
Not published by Easun Power
Strings per tracker
-
1
Not published by Easun Power
Max input current per tracker
-
20.0 A
Not published by Easun Power
Efficiency
European efficiency
-
97.8 %
Not published by Easun Power
Max efficiency
94.0 %
98.3 %
+4.3 pp for MOD 4000TL3-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA)
600-980 V
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) vs 600-980 V
Max charge current
120 A
25 A
+95 A for 4KVA (PVmax=500V, 48V battery)
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
8.2 kg
19.0 kg
-10.8 kg for 4KVA (PVmax=500V, 48V battery)
Weight per kW
2.0 kg/kW
4.8 kg/kW
-2.7 kg/kW for 4KVA (PVmax=500V, 48V battery)
Dimensions
105x295x438 mm
468x408x202 mm
105x295x438 mm vs 468x408x202 mm
Ingress protection
-
IP66
Not published by Easun Power
Cooling
forced-air
natural
forced-air vs natural
Noise
-
29 dB
Not published by Easun Power
Max operating temperature
55 °C
60 °C
+5 °C for MOD 4000TL3-HU
Connectivity and safety
Wi-Fi
-
Yes
Not published by Easun Power
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Easun Power
Integrated DC switch
-
Yes
Not published by Easun Power
Warranty
Warranty
-
10 yrs
Not published by Easun Power
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Easun Power 4KVA (PVmax=500V, 48V battery) vs SolarEdge SE4000H
9 differences, the largest is max efficiency
Same type, similar size
Huawei
Easun Power 4KVA (PVmax=500V, 48V battery) vs Huawei SUN2000L-4KTL
11 differences, the largest is max dc voltage
Same type, similar size
Growatt
Easun Power 4KVA (PVmax=500V, 48V battery) vs Growatt SPM 4000TL-HU
12 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MOD 4000TL3-HU vs Growatt MOD 4000TL3-XH
9 differences, the largest is warranty
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.