2KW (Hybrid Inverter/Charger) vs SUN2000-2KTL-L1 6 of 17 identical Swap Change inverters

Easun Power 2KW (Hybrid Inverter/Charger) vs Huawei SUN2000-2KTL-L1

Easun Power
2KW (Hybrid Inverter/Charger)
2 kW Hybrid
VS
Huawei SUN2000-2KTL-L1
Huawei
SUN2000-2KTL-L1
2 kW 96.7 % euro Hybrid
The verdict

SUN2000-2KTL-L1 leads on the differences that matter

The largest is max dc voltage: 150 V apart. 6 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
6 of 17 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 17 parameters
Parameter 2KW (Hybrid Inverter/Charger) SUN2000-2KTL-L1 Difference
Max DC voltage 450 V 600 V 150 V apart
Max efficiency 95.0 % 98.2 % 3.2 pp more efficient
Max AC power 2.00 kW 2.20 kW 0.20 kW apart
Weight per kW 5.5 kg/kW 6.0 kg/kW 0.5 kg/kW lighter
MPP trackers 1 2 1 tracker more
Weight 11.0 kg 12.0 kg 1.0 kg lighter
Max operating temperature 50 °C 60 °C 10 °C more heat tolerant
Max AC current 8.7 A 10.0 A 1.3 A apart
Battery voltage Nominal 48 Vdc (range not specified) 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh) Nominal 48 Vdc (range not specified) vs 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
Dimensions 468x295x120 mm 365x365x156 mm 468x295x120 mm vs 365x365x156 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter 2KW (Hybrid Inverter/Charger) SUN2000-2KTL-L1 Difference
AC output
Rated AC power 2.00 kW 2.00 kW Same
Max AC power 2.00 kW 2.20 kW 0.20 kW apart
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 8.7 A 10.0 A 1.3 A apart
PV input
Max PV power 3.00 kW 3.00 kW Same
DC/AC ratio 1.50 1.50 Same
Max DC voltage 450 V 600 V 150 V apart
MPPT voltage range - 90-560 V Not published by Easun Power
Start voltage - 100 V Not published by Easun Power
MPP trackers 1 2 +1 trackers for SUN2000-2KTL-L1
Strings per tracker - 1 Not published by Easun Power
Max input current per tracker - 12.5 A Not published by Easun Power
Efficiency
European efficiency - 96.7 % Not published by Easun Power
Max efficiency 95.0 % 98.2 % +3.2 pp for SUN2000-2KTL-L1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage Nominal 48 Vdc (range not specified) 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh) Nominal 48 Vdc (range not specified) vs 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
Max charge current - 15 A Not published by Easun Power
Backup power - - Neither datasheet publishes this
Physical
Weight 11.0 kg 12.0 kg -1.0 kg for 2KW (Hybrid Inverter/Charger)
Weight per kW 5.5 kg/kW 6.0 kg/kW -0.5 kg/kW for 2KW (Hybrid Inverter/Charger)
Dimensions 468x295x120 mm 365x365x156 mm 468x295x120 mm vs 365x365x156 mm
Ingress protection - IP65 Not published by Easun Power
Cooling forced-air natural forced-air vs natural
Noise - - Neither datasheet publishes this
Max operating temperature 50 °C 60 °C +10 °C for SUN2000-2KTL-L1
Connectivity and safety
Wi-Fi - Yes Not published by Easun Power
Ethernet - Yes Not published by Easun Power
Arc fault protection - Yes Not published by Easun Power
Integrated DC switch - Yes Not published by Easun Power
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Easun Power 2KW (Hybrid Inverter/Charger) vs Huawei SUN2000L-2KTL
10 differences, the largest is max dc voltage
Same type, similar size
Easun Power
Easun Power 2KW (Hybrid Inverter/Charger) vs Easun Power IGrid SV II 2KW
One difference: battery voltage
Same type, similar size
SolarEdge
Easun Power 2KW (Hybrid Inverter/Charger) vs SolarEdge SE2200H
12 differences, the largest is rated ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.