Deye SUN-30K-SG01HP3-EU-BM3 vs Growatt MID 30KTL3-XH
VS
The verdict
MID 30KTL3-XH leads on the differences that matter
The largest is max dc voltage: 100 V apart. 8 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
8
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 23 parameters
What actually differs
Parameter
SUN-30K-SG01HP3-EU-BM3
MID 30KTL3-XH
Difference
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
36.0 A
32.0 A
4.0 A more headroom
Max efficiency
97.6 %
98.8 %
1.2 pp more efficient
Max AC power
33.00 kW
30.00 kW
3.00 kW apart
Max PV power
39.00 kW
60.00 kW
21.00 kW apart
DC/AC ratio
1.30
2.00
0.70 more oversizing headroom
Max charge current
100 A
25 A
75 A faster charging
Weight
80.0 kg
31.0 kg
49.0 kg lighter
Weight per kW
2.7 kg/kW
1.0 kg/kW
1.6 kg/kW lighter
Max AC current
50.0 A
45.5 A
4.5 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
150-850 V
160-1000 V
150-850 V vs 160-1000 V
Start voltage
180 V
200 V
20 V earlier start
Battery voltage
160-800
600-980 V
160-800 vs 600-980 V
Dimensions
894x527x294 mm
435x580x230 mm
894x527x294 mm vs 435x580x230 mm
02
Full specification
Parameter
SUN-30K-SG01HP3-EU-BM3
MID 30KTL3-XH
Difference
AC output
Rated AC power
30.00 kW
30.00 kW
Same
Max AC power
33.00 kW
30.00 kW
3.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
50.0 A
45.5 A
4.5 A apart
PV input
Max PV power
39.00 kW
60.00 kW
21.00 kW apart
DC/AC ratio
1.30
2.00
+0.70 for MID 30KTL3-XH
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
150-850 V
160-1000 V
150-850 V vs 160-1000 V
Start voltage
180 V
200 V
-20 V for SUN-30K-SG01HP3-EU-BM3
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
36.0 A
32.0 A
+4.0 A for SUN-30K-SG01HP3-EU-BM3
Efficiency
European efficiency
97.0 %
-
Not published by Growatt
Max efficiency
97.6 %
98.8 %
+1.2 pp for MID 30KTL3-XH
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
160-800
600-980 V
160-800 vs 600-980 V
Max charge current
100 A
25 A
+75 A for SUN-30K-SG01HP3-EU-BM3
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
80.0 kg
31.0 kg
-49.0 kg for MID 30KTL3-XH
Weight per kW
2.7 kg/kW
1.0 kg/kW
-1.6 kg/kW for MID 30KTL3-XH
Dimensions
894x527x294 mm
435x580x230 mm
894x527x294 mm vs 435x580x230 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
65 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Deye
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Deye
Integrated DC switch
-
Yes
Not published by Deye
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Deye SUN-30K-SG01HP3-EU-BM3 vs Ginlong Solis S6-EH3P30K-H
13 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Deye SUN-30K-SG01HP3-EU-BM3 vs Growatt MID 30K-HU
15 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Deye SUN-30K-SG01HP3-EU-BM3 vs Ginlong Solis S6-EH3P30K-H-LV
14 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.