Deye SUN-30K-SG01HP3-EU-BM3 vs Growatt MID 30K-HU
VS
The verdict
MID 30K-HU leads on the differences that matter
The largest is max input current per tracker: 4.0 A more headroom. 10 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
10
of 25 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 25 parameters
What actually differs
Parameter
SUN-30K-SG01HP3-EU-BM3
MID 30K-HU
Difference
Max input current per tracker
36.0 A
40.0 A
4.0 A more headroom
Max efficiency
97.6 %
98.6 %
1.0 pp more efficient
Max AC power
33.00 kW
30.00 kW
3.00 kW apart
Max PV power
39.00 kW
60.00 kW
21.00 kW apart
DC/AC ratio
1.30
2.00
0.70 more oversizing headroom
Max charge current
100 A
42 A
58 A faster charging
Weight
80.0 kg
48.0 kg
32.0 kg lighter
Weight per kW
2.7 kg/kW
1.6 kg/kW
1.1 kg/kW lighter
Noise
65 dB
55 dB
10 dB quieter
European efficiency
97.0 %
97.2 %
0.2 pp more efficient
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
150-850 V
200-1000 V
150-850 V vs 200-1000 V
Start voltage
180 V
160 V
20 V earlier start
Battery voltage
160-800
600-980 V
160-800 vs 600-980 V
Dimensions
894x527x294 mm
570x680x256 mm
894x527x294 mm vs 570x680x256 mm
02
Full specification
Parameter
SUN-30K-SG01HP3-EU-BM3
MID 30K-HU
Difference
AC output
Rated AC power
30.00 kW
30.00 kW
Same
Max AC power
33.00 kW
30.00 kW
3.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
50.0 A
50.0 A
Same
PV input
Max PV power
39.00 kW
60.00 kW
21.00 kW apart
DC/AC ratio
1.30
2.00
+0.70 for MID 30K-HU
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
150-850 V
200-1000 V
150-850 V vs 200-1000 V
Start voltage
180 V
160 V
-20 V for MID 30K-HU
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
36.0 A
40.0 A
+4.0 A for MID 30K-HU
Efficiency
European efficiency
97.0 %
97.2 %
+0.2 pp for MID 30K-HU
Max efficiency
97.6 %
98.6 %
+1.0 pp for MID 30K-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
160-800
600-980 V
160-800 vs 600-980 V
Max charge current
100 A
42 A
+58 A for SUN-30K-SG01HP3-EU-BM3
Backup power
-
30.0 kW
Not published by Deye
Physical
Weight
80.0 kg
48.0 kg
-32.0 kg for MID 30K-HU
Weight per kW
2.7 kg/kW
1.6 kg/kW
-1.1 kg/kW for MID 30K-HU
Dimensions
894x527x294 mm
570x680x256 mm
894x527x294 mm vs 570x680x256 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
65 dB
55 dB
-10 dB for MID 30K-HU
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Deye
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Deye
Integrated DC switch
-
Yes
Not published by Deye
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Deye SUN-30K-SG01HP3-EU-BM3 vs Ginlong Solis S6-EH3P30K-H
13 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Deye SUN-30K-SG01HP3-EU-BM3 vs Ginlong Solis S6-EH3P30K-H-LV
14 differences, the largest is european efficiency
Same type, similar size
Growatt
Deye SUN-30K-SG01HP3-EU-BM3 vs Growatt MID 30KTL3-XH
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.