Deye SUN-30K-SG01HP3-EU-BM3 vs Ginlong Solis S6-EH3P30K-H-LV
VS
The verdict
14 differences, and they point both ways
The largest is european efficiency: 1.5 pp more efficient. 9 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
9
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 23 parameters
What actually differs
Parameter
SUN-30K-SG01HP3-EU-BM3
S6-EH3P30K-H-LV
Difference
European efficiency
97.0 %
95.5 %
1.5 pp more efficient
Max input current per tracker
36.0 A
40.0 A
4.0 A more headroom
Max efficiency
97.6 %
96.3 %
1.3 pp more efficient
Max AC power
33.00 kW
30.00 kW
3.00 kW apart
Max PV power
39.00 kW
60.00 kW
21.00 kW apart
DC/AC ratio
1.30
2.00
0.70 more oversizing headroom
Max charge current
100 A
140 A
40 A faster charging
Weight
80.0 kg
73.0 kg
7.0 kg lighter
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
50.0 A
78.7 A
28.7 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
Weight per kW
2.7 kg/kW
2.4 kg/kW
0.2 kg/kW lighter
Battery voltage
160-800
150-800 V
160-800 vs 150-800 V
Dimensions
894x527x294 mm
880x530x290 mm
894x527x294 mm vs 880x530x290 mm
02
Full specification
Parameter
SUN-30K-SG01HP3-EU-BM3
S6-EH3P30K-H-LV
Difference
AC output
Rated AC power
30.00 kW
30.00 kW
Same
Max AC power
33.00 kW
30.00 kW
3.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
50.0 A
78.7 A
28.7 A apart
PV input
Max PV power
39.00 kW
60.00 kW
21.00 kW apart
DC/AC ratio
1.30
2.00
+0.70 for S6-EH3P30K-H-LV
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
150-850 V
150-850 V
Same
Start voltage
180 V
180 V
Same
MPP trackers
-
3
Not published by Deye
Strings per tracker
2
2
Same
Max input current per tracker
36.0 A
40.0 A
+4.0 A for S6-EH3P30K-H-LV
Efficiency
European efficiency
97.0 %
95.5 %
+1.5 pp for SUN-30K-SG01HP3-EU-BM3
Max efficiency
97.6 %
96.3 %
+1.3 pp for SUN-30K-SG01HP3-EU-BM3
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
160-800
150-800 V
160-800 vs 150-800 V
Max charge current
100 A
140 A
+40 A for S6-EH3P30K-H-LV
Backup power
-
30.0 kW
Not published by Deye
Physical
Weight
80.0 kg
73.0 kg
-7.0 kg for S6-EH3P30K-H-LV
Weight per kW
2.7 kg/kW
2.4 kg/kW
-0.2 kg/kW for S6-EH3P30K-H-LV
Dimensions
894x527x294 mm
880x530x290 mm
894x527x294 mm vs 880x530x290 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
65 dB
-
Not published by Ginlong Solis
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
Yes
Not published by Deye
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
Yes
Not published by Deye
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Deye SUN-30K-SG01HP3-EU-BM3 vs Ginlong Solis S6-EH3P30K-H
13 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Deye SUN-30K-SG01HP3-EU-BM3 vs Growatt MID 30K-HU
15 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Deye SUN-30K-SG01HP3-EU-BM3 vs Growatt MID 30KTL3-XH
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.