Solplanet Ai-HB 200A vs Dyness Tower Pro TP19
VS
The verdict
Tower Pro TP19 leads on the differences that matter
The largest is usable energy: 0.19 kWh apart. 6 of 23 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 17 differencesHow alike are they
6
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
17 of 23 parameters
What actually differs
Parameter
Ai-HB 200A
Tower Pro TP19
Difference
Usable energy
18.43 kWh
18.24 kWh
0.19 kWh apart
Continuous discharge power
12.29 kW
19.20 kW
6.91 kW more power
Cycle life
6000 cycles
8000 cycles
2000 cycles more
Max system capacity
20.5 kWh
23.0 kWh
2.6 kWh more room to expand
Nominal energy
20.48 kWh
19.20 kWh
1.28 kWh apart
Depth of discharge
90 %
95 %
5 pp more of the cells usable
Continuous charge power
10.24 kW
19.20 kW
8.96 kW faster charging
Power per kWh
0.67 kW/kWh
1.05 kW/kWh
0.39 kW/kWh more power for its size
Nominal voltage
410 V
480 V
70 V apart
Weight
259.0 kg
206.0 kg
53.0 kg lighter
Weight per kWh
14.1 kg/kWh
11.3 kg/kWh
2.8 kg/kWh lighter
Cycle test depth
80 %
95 %
15 pp apart
Max operating temperature
50 °C
55 °C
5 °C more heat tolerant
Ingress protection
IP65
IP55
IP65 vs IP55
Modules per stack
3-8
2-6
3-8 vs 2-6
Operating voltage
320-467.2 V
420-547 V
320-467.2 V vs 420-547 V
Dimensions
1250x540x390 mm
1451x587x310 mm
1250x540x390 mm vs 1451x587x310 mm
02
1 shop we track
Price offers
Shop
Ai-HB 200A
Tower Pro TP19
At this shop
Shop prices by brand: See 4 Solplanet offers · See 20 Dyness offers
03
Full specification
Parameter
Ai-HB 200A
Tower Pro TP19
Difference
Capacity
Usable energy
18.43 kWh
18.24 kWh
0.19 kWh apart
Nominal energy
20.48 kWh
19.20 kWh
1.28 kWh apart
Depth of discharge
90 %
95 %
+5 pp for Tower Pro TP19
Max system capacity
20.5 kWh
23.0 kWh
+2.6 kWh for Tower Pro TP19
Modules per stack
3-8
2-6
3-8 vs 2-6
Power
Continuous discharge power
12.29 kW
19.20 kW
+6.91 kW for Tower Pro TP19
Continuous charge power
10.24 kW
19.20 kW
+8.96 kW for Tower Pro TP19
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
0.67 kW/kWh
1.05 kW/kWh
+0.39 kW/kWh for Tower Pro TP19
Efficiency and lifetime
Round-trip efficiency
95.0 %
95.0 %
Same
Cycle life
6000 cycles
8000 cycles
+2000 cycles for Tower Pro TP19
Cycle test depth
80 %
95 %
15 pp apart
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
410 V
480 V
70 V apart
Operating voltage
320-467.2 V
420-547 V
320-467.2 V vs 420-547 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
259.0 kg
206.0 kg
-53.0 kg for Tower Pro TP19
Weight per kWh
14.1 kg/kWh
11.3 kg/kWh
-2.8 kg/kWh for Tower Pro TP19
Dimensions
1250x540x390 mm
1451x587x310 mm
1250x540x390 mm vs 1451x587x310 mm
Ingress protection
IP65
IP55
IP65 vs IP55
Outdoor-rated
Yes
Yes
Same
Min operating temperature
-20 °C
-20 °C
Same
Max operating temperature
50 °C
55 °C
+5 °C for Tower Pro TP19
Warranty
Warranty
-
15 yrs
Not published by Solplanet
Warranted throughput
-
-
Neither datasheet publishes this
04
Open all batteries
More useful comparisons
Similar capacity
Solplanet Ai-HB 200A vs Deye BOS-G20
10 differences, the largest is max system capacity
Similar capacity
Solplanet Ai-HB 200A vs Deye GB-L20
11 differences, the largest is continuous discharge power
Similar capacity
Solplanet Ai-HB 200A vs Deye GB-SL-EU (5 modules in series)
9 differences, the largest is max system capacity
Similar capacity
Dyness Tower Pro TP19 vs FoxESS ECS2900-H7
13 differences, the largest is cycle life
05
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.