Sigenergy SigenStor BAT stack (2 modules) vs Solplanet Ai-HB 175A
VS
The verdict
11 differences, and they point both ways
The largest is continuous discharge power: 2.75 kW more power. 4 of 15 comparable parameters are identical, with 18 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
4
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 15 parameters
What actually differs
Parameter
SigenStor BAT stack (2 modules)
Ai-HB 175A
Difference
Continuous discharge power
8.00 kW
10.75 kW
2.75 kW more power
Max system capacity
48.4 kWh
20.5 kWh
27.9 kWh more room to expand
Nominal energy
16.12 kWh
17.92 kWh
1.80 kWh apart
Continuous charge power
8.00 kW
8.86 kW
0.86 kW faster charging
Weight
164.0 kg
228.5 kg
64.5 kg lighter
Weight per kWh
10.2 kg/kWh
14.2 kg/kWh
4.0 kg/kWh lighter
Power per kWh
0.50 kW/kWh
0.67 kW/kWh
0.17 kW/kWh more power for its size
Max operating temperature
55 °C
50 °C
5 °C more heat tolerant
Ingress protection
IP66
IP65
IP66 vs IP65
Modules per stack
1-6
3-8
1-6 vs 3-8
Dimensions
910x850x260 mm
1120x540x390 mm
910x850x260 mm vs 1120x540x390 mm
Shop prices by brand: See 15 Sigenergy offers · See 4 Solplanet offers
02
Full specification
Parameter
SigenStor BAT stack (2 modules)
Ai-HB 175A
Difference
Capacity
Usable energy
16.12 kWh
16.12 kWh
Same
Nominal energy
16.12 kWh
17.92 kWh
1.80 kWh apart
Depth of discharge
-
90 %
Not published by Sigenergy
Max system capacity
48.4 kWh
20.5 kWh
+27.9 kWh for SigenStor BAT stack (2 modules)
Modules per stack
1-6
3-8
1-6 vs 3-8
Power
Continuous discharge power
8.00 kW
10.75 kW
+2.75 kW for Ai-HB 175A
Continuous charge power
8.00 kW
8.86 kW
+0.86 kW for Ai-HB 175A
Peak discharge power
12.00 kW
-
Not published by Solplanet
Power per kWh
0.50 kW/kWh
0.67 kW/kWh
+0.17 kW/kWh for Ai-HB 175A
Efficiency and lifetime
Round-trip efficiency
-
95.0 %
Not published by Sigenergy
Cycle life
-
6000 cycles
Not published by Sigenergy
Cycle test depth
-
80 %
Not published by Sigenergy
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
-
High voltage
Not published by Sigenergy
Nominal voltage
-
358 V
Not published by Sigenergy
Operating voltage
-
280-408.8 V
Not published by Sigenergy
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
164.0 kg
228.5 kg
-64.5 kg for SigenStor BAT stack (2 modules)
Weight per kWh
10.2 kg/kWh
14.2 kg/kWh
-4.0 kg/kWh for SigenStor BAT stack (2 modules)
Dimensions
910x850x260 mm
1120x540x390 mm
910x850x260 mm vs 1120x540x390 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Outdoor-rated
-
Yes
Not published by Sigenergy
Min operating temperature
-20 °C
-20 °C
Same
Max operating temperature
55 °C
50 °C
+5 °C for SigenStor BAT stack (2 modules)
Warranty
Warranty
-
-
Neither datasheet publishes this
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
Sigenergy SigenStor BAT stack (2 modules) vs Sigenergy SigenStor BAT 8.0 system (2 modules)
3 differences, the largest is usable energy
Similar capacity
Sigenergy SigenStor BAT stack (2 modules) vs SMA Home Storage 16.4
12 differences, the largest is usable energy
Similar capacity
Sigenergy SigenStor BAT stack (2 modules) vs BYD Battery-Box Premium HVM 16.6
6 differences, the largest is usable energy
Similar capacity
Solplanet Ai-HB 175A vs FoxESS HS17.5
8 differences, the largest is usable energy
Similar capacity
Solplanet Ai-HB 175A vs FoxESS ECS2900-H6
10 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.