Skip to main content
GB-L20 vs Tower Pro TP19 6 of 22 identical Swap Change batteries

Deye GB-L20 vs Dyness Tower Pro TP19

Deye GB-L20
GB-L20
18.4 kWh LFP HV
VS
Dyness Tower Pro TP19
Tower Pro TP19
18.24 kWh 95.0 % round-trip LFP HV
The verdict

16 differences, and they point both ways

The largest is usable energy: 0.16 kWh apart. 6 of 22 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
6 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 22 parameters
Parameter GB-L20 Tower Pro TP19 Difference
Usable energy 18.40 kWh 18.24 kWh 0.16 kWh apart
Continuous discharge power 20.48 kW 19.20 kW 1.28 kW more power
Cycle life 6000 cycles 8000 cycles 2000 cycles more
Warranty 10 yrs 15 yrs 5 yrs longer
Max system capacity 24.5 kWh 23.0 kWh 1.5 kWh more room to expand
Nominal energy 20.45 kWh 19.20 kWh 1.25 kWh apart
Depth of discharge 90 % 95 % 5 pp more of the cells usable
Continuous charge power 20.48 kW 19.20 kW 1.28 kW faster charging
Nominal voltage 512 V 480 V 32 V apart
Weight 214.0 kg 206.0 kg 8.0 kg lighter
Max operating temperature 60 °C 55 °C 5 °C more heat tolerant
Ingress protection IP65 IP55 IP65 vs IP55
Power per kWh 1.11 kW/kWh 1.05 kW/kWh 0.06 kW/kWh more power for its size
Weight per kWh 11.6 kg/kWh 11.3 kg/kWh 0.3 kg/kWh lighter
Operating voltage 166.4-700 V 420-547 V 166.4-700 V vs 420-547 V
Dimensions 1310x540x385 mm 1451x587x310 mm 1310x540x385 mm vs 1451x587x310 mm
02

Price offers

1 shop we track
Shop GB-L20 Tower Pro TP19 At this shop
Sklep Soltech Poland - 15 806.56 zł net Only Tower Pro TP19

All 1 offer for Tower Pro TP19

Shop prices by brand: See 44 Deye offers · See 20 Dyness offers

03

Full specification

Parameter GB-L20 Tower Pro TP19 Difference
Capacity
Usable energy 18.40 kWh 18.24 kWh 0.16 kWh apart
Nominal energy 20.45 kWh 19.20 kWh 1.25 kWh apart
Depth of discharge 90 % 95 % +5 pp for Tower Pro TP19
Max system capacity 24.5 kWh 23.0 kWh +1.5 kWh for GB-L20
Modules per stack 2-6 2-6 Same
Power
Continuous discharge power 20.48 kW 19.20 kW +1.28 kW for GB-L20
Continuous charge power 20.48 kW 19.20 kW +1.28 kW for GB-L20
Peak discharge power 25.60 kW - Not published by Dyness
Power per kWh 1.11 kW/kWh 1.05 kW/kWh +0.06 kW/kWh for GB-L20
Efficiency and lifetime
Round-trip efficiency - 95.0 % Not published by Deye
Cycle life 6000 cycles 8000 cycles +2000 cycles for Tower Pro TP19
Cycle test depth - 95 % Not published by Deye
Capacity at end of life 70 % - Not published by Dyness
Self-discharge - - Neither datasheet publishes this
Electrical
Voltage class High voltage High voltage Same
Nominal voltage 512 V 480 V 32 V apart
Operating voltage 166.4-700 V 420-547 V 166.4-700 V vs 420-547 V
Cell chemistry LFP LFP Same
Active cell balancing - - Neither datasheet publishes this
Thermal management Yes - Not published by Dyness
Built-in inverter
Inverter None (battery only) None (battery only) Same
Inverter power - - Neither datasheet publishes this
Grid connection - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 214.0 kg 206.0 kg -8.0 kg for Tower Pro TP19
Weight per kWh 11.6 kg/kWh 11.3 kg/kWh -0.3 kg/kWh for Tower Pro TP19
Dimensions 1310x540x385 mm 1451x587x310 mm 1310x540x385 mm vs 1451x587x310 mm
Ingress protection IP65 IP55 IP65 vs IP55
Outdoor-rated Yes Yes Same
Min operating temperature -20 °C -20 °C Same
Max operating temperature 60 °C 55 °C +5 °C for GB-L20
Warranty
Warranty 10 yrs 15 yrs +5 yrs for Tower Pro TP19
Warranted throughput - - Neither datasheet publishes this
04

More useful comparisons

Open all batteries
Similar capacity
Deye GB-L20 vs Deye GB-SL-EU (5 modules in series)
5 differences, the largest is weight
Similar capacity
Deye GB-L20 vs Solplanet Ai-HB 200A
11 differences, the largest is continuous discharge power
Similar capacity
Deye GB-L20 vs Deye BOS-G20
9 differences, the largest is max system capacity
Similar capacity
Dyness Tower Pro TP19 vs FoxESS ECS2900-H7
13 differences, the largest is cycle life
05

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.