FoxESS HS7.5 vs Dyness Tower Pro TP7
VS
The verdict
Tower Pro TP7 leads on the differences that matter
The largest is cycle life: 2000 cycles more. 4 of 15 comparable parameters are identical, with 18 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
4
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 15 parameters
What actually differs
Parameter
HS7.5
Tower Pro TP7
Difference
Cycle life
6000 cycles
8000 cycles
2000 cycles more
Warranty
10 yrs
15 yrs
5 yrs longer
Usable energy
7.15 kWh
7.30 kWh
0.15 kWh apart
Max system capacity
19.6 kWh
23.0 kWh
3.4 kWh more room to expand
Nominal energy
7.37 kWh
7.68 kWh
0.31 kWh apart
Nominal voltage
154 V
192 V
38 V apart
Min operating temperature
-10 °C
-20 °C
10 °C more cold tolerant
Cycle test depth
80 %
95 %
15 pp apart
Ingress protection
IP21
IP55
IP21 vs IP55
Modules per stack
2-8
2-6
2-8 vs 2-6
Operating voltage
129.6-175.2 V
168-219 V
129.6-175.2 V vs 168-219 V
02
1 shop we track
Price offers
Shop
HS7.5
Tower Pro TP7
At this shop
Shop prices by brand: See 21 FoxESS offers · See 20 Dyness offers
03
Full specification
Parameter
HS7.5
Tower Pro TP7
Difference
Capacity
Usable energy
7.15 kWh
7.30 kWh
0.15 kWh apart
Nominal energy
7.37 kWh
7.68 kWh
0.31 kWh apart
Depth of discharge
-
95 %
Not published by FoxESS
Max system capacity
19.6 kWh
23.0 kWh
+3.4 kWh for Tower Pro TP7
Modules per stack
2-8
2-6
2-8 vs 2-6
Power
Continuous discharge power
-
7.68 kW
Not published by FoxESS
Continuous charge power
-
7.68 kW
Not published by FoxESS
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
-
1.05 kW/kWh
Not published by FoxESS
Efficiency and lifetime
Round-trip efficiency
-
95.0 %
Not published by FoxESS
Cycle life
6000 cycles
8000 cycles
+2000 cycles for Tower Pro TP7
Cycle test depth
80 %
95 %
15 pp apart
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
154 V
192 V
38 V apart
Operating voltage
129.6-175.2 V
168-219 V
129.6-175.2 V vs 168-219 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
-
99.5 kg
Not published by FoxESS
Weight per kWh
-
13.6 kg/kWh
Not published by FoxESS
Dimensions
-
788x587x310 mm
Not published by FoxESS
Ingress protection
IP21
IP55
IP21 vs IP55
Outdoor-rated
-
Yes
Not published by FoxESS
Min operating temperature
-10 °C
-20 °C
-10 °C for Tower Pro TP7
Max operating temperature
55 °C
55 °C
Same
Warranty
Warranty
10 yrs
15 yrs
+5 yrs for Tower Pro TP7
Warranted throughput
-
-
Neither datasheet publishes this
04
Open all batteries
More useful comparisons
Similar capacity
FoxESS HS7.5 vs Dyness Tower T7
6 differences, the largest is nominal energy
Similar capacity
FoxESS HS7.5 vs Deye GB-L8
9 differences, the largest is usable energy
Similar capacity
FoxESS HS7.5 vs Deye GB-SL-EU (2 modules in series)
11 differences, the largest is usable energy
Similar capacity
Dyness Tower Pro TP7 vs FoxESS ECS4300H-H2
13 differences, the largest is usable energy
05
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.