Tower Pro TP15 vs GB-L16 7 of 22 identical Swap Change batteries

Dyness Tower Pro TP15 vs Deye GB-L16

Dyness Tower Pro TP15
Tower Pro TP15
14.59 kWh 95.0 % round-trip LFP HV
VS
Deye GB-L16
GB-L16
14.72 kWh LFP HV
The verdict

15 differences, and they point both ways

The largest is continuous discharge power: 1.02 kW more power. 7 of 22 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
7 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 22 parameters
Parameter Tower Pro TP15 GB-L16 Difference
Continuous discharge power 15.36 kW 16.38 kW 1.02 kW more power
Cycle life 8000 cycles 6000 cycles 2000 cycles more
Warranty 15 yrs 10 yrs 5 yrs longer
Usable energy 14.59 kWh 14.72 kWh 0.13 kWh apart
Max system capacity 23.0 kWh 24.5 kWh 1.5 kWh more room to expand
Nominal energy 15.36 kWh 16.36 kWh 1.00 kWh apart
Depth of discharge 95 % 90 % 5 pp more of the cells usable
Continuous charge power 15.36 kW 16.38 kW 1.02 kW faster charging
Nominal voltage 384 V 410 V 26 V apart
Weight 170.5 kg 175.0 kg 4.5 kg lighter
Max operating temperature 55 °C 60 °C 5 °C more heat tolerant
Ingress protection IP55 IP65 IP55 vs IP65
Power per kWh 1.05 kW/kWh 1.11 kW/kWh 0.06 kW/kWh more power for its size
Operating voltage 336-438 V 166.4-700 V 336-438 V vs 166.4-700 V
Dimensions 1230x587x310 mm 1090x540x385 mm 1230x587x310 mm vs 1090x540x385 mm
02

Price offers

1 shop we track
Shop Tower Pro TP15 GB-L16 At this shop
Sklep Soltech Poland 12 990.88 zł net - Only Tower Pro TP15

All 1 offer for Tower Pro TP15

Shop prices by brand: See 20 Dyness offers · See 44 Deye offers

03

Full specification

Parameter Tower Pro TP15 GB-L16 Difference
Capacity
Usable energy 14.59 kWh 14.72 kWh 0.13 kWh apart
Nominal energy 15.36 kWh 16.36 kWh 1.00 kWh apart
Depth of discharge 95 % 90 % +5 pp for Tower Pro TP15
Max system capacity 23.0 kWh 24.5 kWh +1.5 kWh for GB-L16
Modules per stack 2-6 2-6 Same
Power
Continuous discharge power 15.36 kW 16.38 kW +1.02 kW for GB-L16
Continuous charge power 15.36 kW 16.38 kW +1.02 kW for GB-L16
Peak discharge power - 20.48 kW Not published by Dyness
Power per kWh 1.05 kW/kWh 1.11 kW/kWh +0.06 kW/kWh for GB-L16
Efficiency and lifetime
Round-trip efficiency 95.0 % - Not published by Deye
Cycle life 8000 cycles 6000 cycles +2000 cycles for Tower Pro TP15
Cycle test depth 95 % - Not published by Deye
Capacity at end of life - 70 % Not published by Dyness
Self-discharge - - Neither datasheet publishes this
Electrical
Voltage class High voltage High voltage Same
Nominal voltage 384 V 410 V 26 V apart
Operating voltage 336-438 V 166.4-700 V 336-438 V vs 166.4-700 V
Cell chemistry LFP LFP Same
Active cell balancing - - Neither datasheet publishes this
Thermal management - Yes Not published by Dyness
Built-in inverter
Inverter None (battery only) None (battery only) Same
Inverter power - - Neither datasheet publishes this
Grid connection - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 170.5 kg 175.0 kg -4.5 kg for Tower Pro TP15
Weight per kWh 11.7 kg/kWh 11.9 kg/kWh Effectively the same
Dimensions 1230x587x310 mm 1090x540x385 mm 1230x587x310 mm vs 1090x540x385 mm
Ingress protection IP55 IP65 IP55 vs IP65
Outdoor-rated Yes Yes Same
Min operating temperature -20 °C -20 °C Same
Max operating temperature 55 °C 60 °C +5 °C for GB-L16
Warranty
Warranty 15 yrs 10 yrs +5 yrs for Tower Pro TP15
Warranted throughput - - Neither datasheet publishes this
04

More useful comparisons

Open all batteries
Similar capacity
Dyness Tower Pro TP15 vs Deye GB-SL-EU (4 modules in series)
15 differences, the largest is cycle life
Similar capacity
Dyness Tower Pro TP15 vs FoxESS HS15
11 differences, the largest is usable energy
Similar capacity
Dyness Tower Pro TP15 vs FoxESS ECS4300H-H4
13 differences, the largest is usable energy
Similar capacity
Deye GB-L16 vs Huawei LUNA2000-15-S0
15 differences, the largest is usable energy
05

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.