Deye AI-W5.1-B (6 modules) vs Sigenergy SigenStor BAT stack (3 modules)
VS
The verdict
10 differences, and they point both ways
The largest is usable energy: 3.42 kWh apart. 6 of 16 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
6
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 16 parameters
What actually differs
Parameter
AI-W5.1-B (6 modules)
SigenStor BAT stack (3 modules)
Difference
Usable energy
27.60 kWh
24.18 kWh
3.42 kWh apart
Continuous discharge power
12.80 kW
12.00 kW
0.80 kW more power
Max system capacity
30.7 kWh
48.4 kWh
17.6 kWh more room to expand
Nominal energy
30.72 kWh
24.18 kWh
6.54 kWh apart
Continuous charge power
12.80 kW
12.00 kW
0.80 kW faster charging
Peak discharge power
18.43 kW
18.00 kW
0.43 kW more surge
Weight
339.5 kg
237.0 kg
102.5 kg lighter
Weight per kWh
12.3 kg/kWh
9.8 kg/kWh
2.5 kg/kWh lighter
Ingress protection
IP65 (after stacking)
IP66
IP65 (after stacking) vs IP66
Dimensions
1974x720x255 mm
1180x850x260 mm
1974x720x255 mm vs 1180x850x260 mm
Shop prices by brand: See 44 Deye offers · See 15 Sigenergy offers
02
Full specification
Parameter
AI-W5.1-B (6 modules)
SigenStor BAT stack (3 modules)
Difference
Capacity
Usable energy
27.60 kWh
24.18 kWh
3.42 kWh apart
Nominal energy
30.72 kWh
24.18 kWh
6.54 kWh apart
Depth of discharge
90 %
-
Not published by Sigenergy
Max system capacity
30.7 kWh
48.4 kWh
+17.6 kWh for SigenStor BAT stack (3 modules)
Modules per stack
1-6
1-6
Same
Power
Continuous discharge power
12.80 kW
12.00 kW
+0.80 kW for AI-W5.1-B (6 modules)
Continuous charge power
12.80 kW
12.00 kW
+0.80 kW for AI-W5.1-B (6 modules)
Peak discharge power
18.43 kW
18.00 kW
+0.43 kW for AI-W5.1-B (6 modules)
Power per kWh
0.46 kW/kWh
0.50 kW/kWh
Effectively the same
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
6000 cycles
-
Not published by Sigenergy
Cycle test depth
90 %
-
Not published by Sigenergy
Capacity at end of life
70 %
-
Not published by Sigenergy
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
Low voltage
-
Not published by Sigenergy
Nominal voltage
51 V
-
Not published by Sigenergy
Operating voltage
43.2-57.6 V
-
Not published by Sigenergy
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
339.5 kg
237.0 kg
-102.5 kg for SigenStor BAT stack (3 modules)
Weight per kWh
12.3 kg/kWh
9.8 kg/kWh
-2.5 kg/kWh for SigenStor BAT stack (3 modules)
Dimensions
1974x720x255 mm
1180x850x260 mm
1974x720x255 mm vs 1180x850x260 mm
Ingress protection
IP65 (after stacking)
IP66
IP65 (after stacking) vs IP66
Outdoor-rated
-
-
Neither datasheet publishes this
Min operating temperature
-20 °C
-20 °C
Same
Max operating temperature
55 °C
55 °C
Same
Warranty
Warranty
10 yrs
-
Not published by Sigenergy
Warranted throughput
16.0 MWh
-
Not published by Sigenergy
03
Open all batteries
More useful comparisons
Similar capacity
Deye AI-W5.1-B (6 modules) vs Deye AI-W5.1-B (5 modules)
5 differences, the largest is usable energy
Similar capacity
Deye AI-W5.1-B (6 modules) vs Deye BOS-G30
9 differences, the largest is max system capacity
Similar capacity
Deye AI-W5.1-B (6 modules) vs FoxESS ECS4300H-H7
11 differences, the largest is usable energy
Similar capacity
Sigenergy SigenStor BAT stack (3 modules) vs Sigenergy SigenStor BAT 8.0 system (3 modules)
3 differences, the largest is usable energy
Similar capacity
Sigenergy SigenStor BAT stack (3 modules) vs Deye BOS-G25
8 differences, the largest is usable energy
Similar capacity
Sigenergy SigenStor BAT stack (3 modules) vs Deye BOS-G25 Pro
12 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.