Skip to main content
AI-W5.1-B (6 modules) vs ECS4300H-H7 7 of 18 identical Swap Change batteries

Deye AI-W5.1-B (6 modules) vs FoxESS ECS4300H-H7

AI-W5.1-B (6 modules)
27.6 kWh LFP LV
VS
FoxESS ECS4300H-H7
ECS4300H-H7
26.13 kWh 95.0 % round-trip LFP HV
The verdict

ECS4300H-H7 leads on the differences that matter

The largest is usable energy: 1.47 kWh apart. 7 of 18 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
7 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 18 parameters
Parameter AI-W5.1-B (6 modules) ECS4300H-H7 Difference
Usable energy 27.60 kWh 26.13 kWh 1.47 kWh apart
Max system capacity 30.7 kWh 29.0 kWh 1.7 kWh more room to expand
Nominal energy 30.72 kWh 29.03 kWh 1.69 kWh apart
Nominal voltage 51 V 403 V 352 V apart
Weight 339.5 kg 263.5 kg 76.0 kg lighter
Weight per kWh 12.3 kg/kWh 10.1 kg/kWh 2.2 kg/kWh lighter
Voltage class Low voltage High voltage Low voltage vs High voltage
Ingress protection IP65 (after stacking) IP65 IP65 (after stacking) vs IP65
Modules per stack 1-6 2-7 1-6 vs 2-7
Operating voltage 43.2-57.6 V 340.2-459.9 V 43.2-57.6 V vs 340.2-459.9 V
Dimensions 1974x720x255 mm 1006x570x380 mm 1974x720x255 mm vs 1006x570x380 mm

Shop prices by brand: See 44 Deye offers · See 21 FoxESS offers

02

Full specification

Parameter AI-W5.1-B (6 modules) ECS4300H-H7 Difference
Capacity
Usable energy 27.60 kWh 26.13 kWh 1.47 kWh apart
Nominal energy 30.72 kWh 29.03 kWh 1.69 kWh apart
Depth of discharge 90 % 90 % Same
Max system capacity 30.7 kWh 29.0 kWh +1.7 kWh for AI-W5.1-B (6 modules)
Modules per stack 1-6 2-7 1-6 vs 2-7
Power
Continuous discharge power 12.80 kW - Not published by FoxESS
Continuous charge power 12.80 kW - Not published by FoxESS
Peak discharge power 18.43 kW - Not published by FoxESS
Power per kWh 0.46 kW/kWh - Not published by FoxESS
Efficiency and lifetime
Round-trip efficiency - 95.0 % Not published by Deye
Cycle life 6000 cycles 6000 cycles Same
Cycle test depth 90 % 90 % Same
Capacity at end of life 70 % - Not published by FoxESS
Self-discharge - - Neither datasheet publishes this
Electrical
Voltage class Low voltage High voltage Low voltage vs High voltage
Nominal voltage 51 V 403 V 352 V apart
Operating voltage 43.2-57.6 V 340.2-459.9 V 43.2-57.6 V vs 340.2-459.9 V
Cell chemistry LFP LFP Same
Active cell balancing - - Neither datasheet publishes this
Thermal management - - Neither datasheet publishes this
Built-in inverter
Inverter None (battery only) None (battery only) Same
Inverter power - - Neither datasheet publishes this
Grid connection - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 339.5 kg 263.5 kg -76.0 kg for ECS4300H-H7
Weight per kWh 12.3 kg/kWh 10.1 kg/kWh -2.2 kg/kWh for ECS4300H-H7
Dimensions 1974x720x255 mm 1006x570x380 mm 1974x720x255 mm vs 1006x570x380 mm
Ingress protection IP65 (after stacking) IP65 IP65 (after stacking) vs IP65
Outdoor-rated - Yes Not published by Deye
Min operating temperature -20 °C -20 °C Same
Max operating temperature 55 °C 55 °C Same
Warranty
Warranty 10 yrs - Not published by FoxESS
Warranted throughput 16.0 MWh - Not published by FoxESS
03

More useful comparisons

Open all batteries
Similar capacity
Deye AI-W5.1-B (6 modules) vs Deye AI-W5.1-B (5 modules)
5 differences, the largest is usable energy
Similar capacity
Deye AI-W5.1-B (6 modules) vs Deye BOS-G30
9 differences, the largest is max system capacity
Similar capacity
Deye AI-W5.1-B (6 modules) vs Sigenergy SigenStor BAT stack (3 modules)
10 differences, the largest is usable energy
Similar capacity
FoxESS ECS4300H-H7 vs Deye BOS-G25
10 differences, the largest is usable energy
Similar capacity
FoxESS ECS4300H-H7 vs Deye BOS-G25 Pro
10 differences, the largest is usable energy
Similar capacity
FoxESS ECS4300H-H7 vs FoxESS ECS4300H-H6
6 differences, the largest is usable energy
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.