Skip to main content
Ulica Solar UL-455M-108BHVN

UL-455M-108BHVN

455 Wp TOPCon
ComparePV verdict

Light for its output, no clear weak spot

Rank 7,760 of 14,005
Compare panels Datasheet PDF
Power (Wp)
455
Typical for its class
Efficiency (%)
22.77
Typical · median 22.52%
Density (Wp/m²)
227.7
Typical · median 225.2
Temp (%/°C)
-0.290
Typical · median -0.290
Weight (kg)
20.6
Strong · 3.4 kg below median
Warranty (yrs)
30
Typical · median 30 yrs

The TOPCon N-TYPE Mono-Facial series from Ulica Solar provides a solution to the increasing demands of installations, where durability and long-term stability are paramount. By utilizing monocrystalline N-type cells and TOPCon technology, these modules exhibit significantly lower annual degradation compared to P-type based solutions - resulting in a demonstrably higher energy production over the long term. The series is distinguished by a cutting technology that minimizes micro-cracks, which reduces the risk of mechanical damage to the cells during production, directly impacting the module's reliability throughout its lifespan. The modules have undergone rigorous PID (Potential-Induced Degradation) resistance testing under hot and humid conditions (relative humidity of 85%) for 96 hours - making them exceptionally suitable for challenging climatic locations in Poland. Their exceptional mechanical strength - wind loads up to 3800 Pa and snow loads up to 5400 Pa - make them suitable for both rooftop installations on residential buildings and large-scale ground-mounted farms. The manufacturer offers a 15-year product warranty and a 30-year linear power warranty with a degradation rate not exceeding 0.4% per year.

Ranking

1,089 panels in the segment TOPCon 450-500 W
Metric This panel Median Position in segment Overall rank
Module efficiency 22.77% 22.52% Typical 3,073
Power density 227.7 225.2 Typical 2,888
Temperature coefficient -0.290 -0.290 Typical 2,165
Weight per kWp 45.3 52.2 Strong · top 9% 674
Performance warranty 30 yrs 30 yrs Typical 21
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Price offers

1 from shops we track
Shop Country Price Per kWp Stock Offer updated Link to shop
AID Solar Poland 350 zł incl. VAT 769.23 zł/kWp In stock 18h ago Visit shop

Signals from the data

1 positive · 0 caution
Best for

Residential and commercial.

Strengths
45.3 kg per kWp

Top 9% of the TOPCon 450-500 W segment, against a median of 52.2. Ranked 674th in the whole database.

Notes from the database
  • Efficiency of 22.8% matches the TOPCon 450-500W median
  • At 227.7 W/m² power density, roof space requirements are typical for TOPCon 450-500W panels
  • Temperature coefficient of -0.29%/°C matches the TOPCon 450-500W median
  • At 20.6 kg, this panel is 3.4 kg lighter than TOPCon 450-500W median (24.0 kg) - easier handling during installation
  • #3073 for efficiency, #2165 for temperature performance out of 14005 panels

Specifications

Open datasheet PDF
Nominal power (Pmax) 455 Wp Nameplate at 1000 W/m², 25 °C
Module efficiency 22.77 % Typical Segment median 22.52%
Vmpp · Impp 33.42 V · 13.61 A Operating point at max power
Voc · Isc 39.98 V · 14.45 A Sizes the string length
Max system voltage 1500 V Longer strings than 1000 V modules
Dimensions 1762×1134×30 mm · 2.00 m² of roof
Weight 20.6 kg Strong Strong · 3.4 kg below median
Cells 108 · TOPCon Monocrystalline
Coefficient Pmax -0.290 %/°C Typical median -0.290 of its segment
Coefficient Voc · Isc -0.250 · 0.046 %/°C
NOCT 43 °C At 800 W/m², 20 °C ambient
Product warranty 15 years Hardware defects only
Performance warranty 30 years Typical median 30 yrs · median 30 yrs
End-of-warranty output 87.4 % Equals 398 W guaranteed
Degradation 1.00 → 0.40 % First year, then annual

Datasheet charts

Open datasheet PDF

Measured curves published by Ulica Solar in this model's datasheet. A chart carrying a wattage was measured on that variant alone - only the ones that describe 455 Wp appear here. The rest cover the whole series.

Simulations

Live - change any input
Lifetime output & value
30 years at 1200 kWh/kWp/year and €0.50 per kWh
Power in year 30
-
Lifetime energy
-
Energy value
-

Degradation from this panel's own datasheet figures. No inverter, soiling or shading losses.

Heat losses
-0.290 %/°C against a segment median of -0.290
-
Filter these
Size
Panel Power Eff. Temp. Weight Difference
Ulica Solar UL-455M-108BHVN 455 W 22.77% -0.290 20.6 kg You are here
AIKO-A495-MCE54Mw 495 W 24.80% -0.260 21.0 kg +40 W, cooler, +2.0 pp
LR7-54HJD-505M 505 W 24.70% -0.240 23.5 kg +50 W, cooler, +1.9 pp
AIKO-A490-MCE54Mw 490 W 24.50% -0.260 21.0 kg +35 W, cooler, +1.7 pp
LR7-54HJD-500M 500 W 24.50% -0.240 23.5 kg +45 W, cooler, +1.7 pp
CIPRO-TN9C54M-500W 500 W 24.50% -0.260 21.4 kg +45 W, cooler, +1.7 pp
GK-3-54HGb-500M 500 W 24.50% -0.260 21.4 kg +45 W, cooler, +1.7 pp
UL-440M-108BHVN 440 W 22.02% -0.290 20.6 kg -15 W, -0.8 pp
UL-445M-108BDGN 445 W 22.27% -0.290 24.0 kg -10 W, heavier, -0.5 pp
UL-450M-108BDGN 450 W 22.52% -0.290 24.0 kg Heavier, -0.2 pp
UL-460M-108BDGN 460 W 23.02% -0.290 24.0 kg Heavier, +0.2 pp
LR7-54HJD-510M 510 W 25.00% -0.240 23.5 kg +55 W, cooler, +2.2 pp

Found 1395 panels of the same or similar size to this one, within ±10 mm. See them here Found 1425 panels of the same or similar size to this one, within ±25 mm. See them here Found 3614 panels of the same or similar size to this one, within ±50 mm. See them here Found 3962 panels of the same or similar size to this one, within ±100 mm. See them here

Common questions

6 answered
How does the Ulica Solar TOPCon N-TYPE panel differ from standard P-type modules?
The N-type cells used in this series have significantly lower annual degradation than popular P-type PERC modules, resulting in higher energy yield over a 20-30 year horizon. TOPCon technology further boosts conversion efficiency through a passivation layer that reduces rear-surface losses on the cell. In practice, this means a panel that loses power more slowly and performs better in installations designed to last for decades.
What warranty comes with the Ulica Solar TOPCon 440-455W panels?
The manufacturer provides a 15-year product warranty along with a 30-year linear power warranty, with maximum degradation not exceeding 0.4% per year. This means that after 30 years of operation, the panel should still deliver a high percentage of its rated power, which is an important factor when calculating the long-term return on investment for a solar installation.
Are Ulica Solar TOPCon panels suitable for harsh climate conditions in Poland?
Yes, the modules passed a rigorous PID resistance test under damp heat conditions at 85% relative humidity for 96 hours, confirming their resistance to potential-induced degradation, which is common in humid climates. They also withstand wind loads up to 3800 Pa and snow loads up to 5400 Pa, making them well-suited for Polish winters with heavy snowfall and strong winds.
Will the TOPCon 440-455W series work on a sloped residential roof?
Yes, the high mechanical load resistance for wind and snow makes these panels well-suited for rooftop installations on residential buildings, including sloped roofs. With up to 455 Wp of power, the modules deliver high output from a limited roof area, which matters on the smaller roof surfaces typical of single-family homes.
What is the benefit of the micro-crack-free cutting technology in Ulica Solar panels?
The micro-crack-free cutting technology minimizes the risk of mechanical cell damage as early as the manufacturing stage. Micro-cracks caused by conventional laser cutting can lead to hot spots and accelerated power degradation over time. This technology helps the panel maintain higher reliability and stable performance throughout its service life, supporting the stated 30-year power warranty.
Are the TOPCon 440-455W Ulica Solar panels bifacial modules?
No, this series consists of mono-facial modules that generate energy only from the front side of the panel. This makes them simpler to install and price compared to bifacial modules, which require suitable mounting structures and a reflective ground surface to take advantage of rear-side gain. They perform reliably in standard rooftop and ground-mount installations without special albedo requirements.
Add to compare