Skip to main content

HY-DH96N11B-440

440 Wp N-type Bifacial 80%
ComparePV verdict

Middle of its segment, heavy for its output

Rank 9,874 of 14,005
Compare panels Datasheet PDF
Power (Wp)
440
Strong · top 23%
Efficiency (%)
22.00
Typical · median 21.91%
Density (Wp/m²)
220.2
Typical · median 218.3
Temp (%/°C)
-0.290
Typical · median -0.290
Weight (kg)
25.0
Weak · 3.0 kg above median
Warranty (yrs)
30
Typical · median 30 yrs

The HY-DH96N11B series consists of dual-sided photovoltaic modules built on N-Type TOPCon 210R cells in a half-cut configuration, engineered for installations that need to squeeze the most energy out of every square meter of roof or ground space. Thanks to bifacial technology, the panels capture light reflected off the surrounding surface, meaningfully boosting energy yield without expanding the footprint of the installation - a solution particularly appealing for solar farms and commercial projects where every extra kilowatt-hour matters. The dual-glass construction, with tempered glass on both sides of the cells, improves mechanical durability and extends module lifespan while reducing PID degradation and improving performance in low-light conditions. A low temperature coefficient keeps the series performing steadily even on hot days, translating into a lower LCOE over the system's full lifecycle. HY-DH96N11B works equally well in commercial-scale projects and larger prosumer installations, where investors expect reliability, predictable return on investment, and reduced power losses across the BoS. It's the choice for installers who want to offer clients a modern, proven N-Type technology instead of aging PERC solutions.

Ranking

321 panels in the segment N-type 400-450 W
Metric This panel Median Position in segment Overall rank
Module efficiency 22.00% 21.91% Typical 6,517
Power density 220.2 218.3 Typical 6,328
Temperature coefficient -0.290 -0.290 Typical 2,165
Weight per kWp 56.8 51.2 Weak · bottom 13% 10,878
Performance warranty 30 yrs 30 yrs Typical 21
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Signals from the data

0 positive · 1 caution
Best for

Commercial, utility-scale and shaded-installations.

Not ideal for

Weight-limited structures.

Watch-outs
56.8 kg per kWp

Bottom 13% of the N-type 400-450 W segment, against a median of 51.2.

Notes from the database
  • At 22.0% efficiency, this panel is on par with typical N-type 400-450W modules
  • Power density of 220.2 W/m² matches the N-type 400-450W median
  • At -0.29%/°C, hot weather performance is typical for N-type 400-450W panels
  • At 25.0 kg, this panel is 3.0 kg heavier than the N-type 400-450W median (22.0 kg) - more demanding for installation crews
  • 80% bifaciality enables rear-side power generation, boosting yield by 4-12% on reflective surfaces

Specifications

Open datasheet PDF
Nominal power (Pmax) 440 Wp Nameplate at 1000 W/m², 25 °C
Module efficiency 22.00 % Typical Segment median 21.91%
Vmpp · Impp 29.16 V · 15.09 A Operating point at max power
Voc · Isc 34.98 V · 15.91 A Sizes the string length
Max system voltage 1500 V Longer strings than 1000 V modules
Dimensions 1762×1134×30 mm · 2.00 m² of roof
Weight 25.0 kg Weak Weak · 3.0 kg above median
Cells 96 · N-type Monocrystalline
Bifaciality 80 % Rear output as a share of front
Coefficient Pmax -0.290 %/°C Typical median -0.290 of its segment
Coefficient Voc · Isc -0.250 · 0.045 %/°C
NOCT 45 °C At 800 W/m², 20 °C ambient
Product warranty 12 years Hardware defects only
Performance warranty 30 years Typical median 30 yrs · median 30 yrs
End-of-warranty output 87.4 % Equals 385 W guaranteed
Degradation 1.00 → 0.40 % First year, then annual

Datasheet charts

Open datasheet PDF

Measured curves published by Runergy in this model's datasheet. A chart carrying a wattage was measured on that variant alone - only the ones that describe 440 Wp appear here. The rest cover the whole series.

Simulations

Live - change any input
Lifetime output & value
30 years at 1200 kWh/kWp/year and €0.50 per kWh
Power in year 30
-
Lifetime energy
-
Energy value
-
With bifacial gain
-

Degradation from this panel's own datasheet figures. No inverter, soiling or shading losses.

Heat losses
-0.290 %/°C against a segment median of -0.290
-
Bifacial gain
Rear gain over light concrete: -
-

Model: bifaciality × albedo × 0.6 view factor. A first-order estimate, not a yield simulation.

Filter these
Size
Panel Power Eff. Temp. Weight Difference
Runergy HY-DH96N11B-440 440 W 22.00% -0.290 25.0 kg You are here
AIKO-A490-MCE54Mw 490 W 24.50% -0.260 21.0 kg +50 W, lighter, +2.5 pp
STP-NT11/48QGSF-490 490 W 24.50% -0.260 21.5 kg +50 W, lighter, +2.5 pp
JAT54S40-485/LR 485 W 24.30% -0.260 19.3 kg +45 W, lighter, +2.3 pp
AIKO-A485-MCE54Mw 485 W 24.30% -0.260 21.0 kg +45 W, lighter, +2.3 pp
AIKO-A485-MAH54Mw 485 W 24.30% -0.260 21.5 kg +45 W, lighter, +2.3 pp
GK-5-54HG-485M 485 W 24.30% -0.260 21.0 kg +45 W, lighter, +2.3 pp
ZEUS 3.0+ 108 485WP 485 W 24.30% -0.260 24.2 kg +45 W, cooler, +2.3 pp
HY-DH96N11B-435 435 W 22.00% -0.290 25.0 kg Very close match
HY-DH96N11-445 445 W 22.30% -0.290 25.0 kg +0.3 pp
HY-DH96N11B-450 450 W 22.50% -0.290 25.0 kg +10 W, +0.5 pp
LR7-54HJD-510M 510 W 25.00% -0.240 23.5 kg +70 W, cooler, +3.0 pp
AIKO-A495-MCE54Mw 495 W 24.80% -0.260 21.0 kg +55 W, lighter, +2.8 pp
LR7-54HJD-505M 505 W 24.70% -0.240 23.5 kg +65 W, cooler, +2.7 pp
LR7-54HJD-500M 500 W 24.50% -0.240 23.5 kg +60 W, cooler, +2.5 pp
CIPRO-TN9C54M-500W 500 W 24.50% -0.260 21.4 kg +60 W, lighter, +2.5 pp

Found 1395 panels of the same or similar size to this one, within ±10 mm. See them here Found 1425 panels of the same or similar size to this one, within ±25 mm. See them here Found 3614 panels of the same or similar size to this one, within ±50 mm. See them here Found 3962 panels of the same or similar size to this one, within ±100 mm. See them here

Common questions

6 answered
What is the maximum power output of the Runergy HY-DH96N11B panel?
The HY-DH96N11B series reaches a maximum power output of up to 440 Wp. This is achieved thanks to N-Type TOPCon 210R half-cut cells, which reduce current losses and improve conversion efficiency compared to older PERC technology. Higher module wattage means fewer panels are needed for a given system size, lowering mounting structure and labor costs.
How does N-Type TOPCon technology in the HY-DH96N11B differ from PERC panels?
N-Type TOPCon cells have a lower annual degradation rate and are less susceptible to LID and LeTID compared to P-type PERC cells. As a result, HY-DH96N11B panels maintain higher efficiency over time, perform better under low irradiance, and have a lower temperature coefficient, translating into more stable energy yield on hot days.
What is the warranty on Runergy HY-DH96N11B panels?
The HY-DH96N11B series comes with a 12-year product warranty covering material and workmanship defects, along with a 30-year linear power warranty guaranteeing a defined performance level over the module's lifespan. This is standard for modern N-Type modules and significantly longer than typical PERC panels, contributing to a lower LCOE for the installation.
Is Runergy a tier 1 manufacturer, and can it be trusted for large commercial installations?
Yes, Runergy is classified as a tier 1 manufacturer, meaning stable financial standing, in-house production lines, and inclusion in Bloomberg NEF's rankings of bankable PV module suppliers. The company is headquartered in China and exports to commercial markets and solar farms, where supply reliability and long-term warranty support matter most.
Are HY-DH96N11B panels suitable for large ground-mount and commercial installations?
Yes, the dual-glass construction with tempered glass on both sides of the cells increases mechanical strength and reduces PID degradation, which matters for large solar farms exposed to variable weather conditions. High single-module power output (up to 440 Wp) combined with a low temperature coefficient makes this series suitable for both commercial projects and larger residential/prosumer installations.
Do HY-DH96N11B panels perform well in hot summer conditions?
Yes, thanks to the low temperature coefficient of N-Type TOPCon cells, HY-DH96N11B modules lose less power as operating temperature rises compared to PERC-based designs. This means more stable energy yield on hot, sunny days when panel temperature can exceed 60°C, resulting in a better real-world return on investment in warmer climates.
Add to compare