Skip to main content
Home Tools Panel comparison calculator Report
30-year simulation report

A close run between six modules

LR7-54HVH-490M delivers 12,759 kWh over 30 years at 0.71 c/kWh, which makes its energy 17% cheaper per kilowatt-hour than the dearest module in this report. It is not the cheapest sticker price in the set - €69 is - and it still wins.

6 November 2026, 11:21 de9b26ea-57d7 Saved - link stays live
Download PDF
Best long-term value
LR7-54HVH-490M 490 Wp
  • Most energy produced. 12,759 kWh over 30 years, 1,110 kWh ahead of the next module.
  • Best composite in the set. It scores highest across lifetime energy, cost per kWh and warranty length taken together, even though it is not the cheapest energy in the set.
70 of 100
Cost per kWh 0.71 c/kWh
Ranking leader
LR7-54HVH-490M
Score 70 of 100
Highest 30-year yield
12,759 kWh
1,750 kWh above the lowest module
Lowest cost per kWh
0.61 c/kWh
29% cheaper than the dearest
Modules compared
6
Prices entered by the requester
Assumptions Cell temperature55 °C InstallationFlat roof Baseline yield1,000 kWh/kWp Horizon30 years CurrencyEUR Change and re-run
01

Side by side

# Manufacturer / model Power Price Year 1 30-year Cost per kWh Score
1 LR7-54HVH-490M 490 Wp €90 447 12,759 0.71 c/kWh Most energy produced 70
2 HiT-H450CE-BF 450 Wp €69 409 11,347 0.61 c/kWh Cheapest energy in the set 61
3 TSM-NEG9R.25 455W 455 Wp €81.90 411 11,648 0.70 c/kWh 51
4 TSM-NEG9R.28 450W 450 Wp €83.19 407 11,520 0.72 c/kWh 45
5 TSM-NEG9RC.27-435 435 Wp €94.12 393 11,136 0.85 c/kWh 21
6 TSM-430NEG9RC.27 430 Wp €94.12 389 11,008 0.85 c/kWh Weakest of the set 19
top 25% middle 50% bottom 25% Bands are relative to the modules in this report.

What drives each score

Each bar is the module's own composite, split into the three weighted parts that make it up. A dimension the whole set ties on separates nothing and splits evenly, and one they nearly tie on counts for nearly nothing.

LR7-54HVH-490M 70
HiT-H450CE-BF 61
TSM-NEG9R.25 455W 50
TSM-NEG9R.28 450W 45
TSM-NEG9RC.27-435 21
TSM-430NEG9RC.27 19
30-year yield · 45%Cost per kWh · 40%Warranty · 15%
02

Where the difference comes from

Cumulative energy

Kilowatt-hours added up year by year. The gap widens with every year - by year 30 it is 1,750 kWh between the highest and lowest module.

Power remaining

Percentage of nameplate power still delivered, on each module's own datasheet curve. A module that holds its power longer is producing from a bigger number every year.

03

Method

Full methodology
How each figure is built
1 Annual yield Panel watts times the installation baseline of 1,000 kWh/kWp, times a temperature factor from the module's own coefficient at 55 °C, times whatever degradation has left that year.
2 Degradation Each module ages at its own datasheet rate - LR7-54HVH-490M loses 1% in year one, then 0.35% a year. Where a manufacturer publishes no curve, the 2% / 0.55% convention is used.
3 Cost per kWh Offer price divided by the thirty annual yields added together. The only figure that lets a dearer module win, and often it does.
4 Score A 0-100 composite: lifetime energy 45%, cost per kWh 40%, warranty 15%, each normalised across this report's modules. A dimension they all tie on splits evenly.
What this does not model

Energy price inflation, inverter and installation cost, local irradiance and weather, shading, or degradation behaviour that differs from the datasheet curve. This report compares modules against each other, not a full system business case. Talk to an installer before you buy.

Sources
Panel specifications read from manufacturer datasheets, refreshed daily.
Prices entered by whoever generated this report - not quotes we obtained or verified.
Baseline yield from the installation type, overridable with PVGIS data.
Generated by ComparePV on 6 November 2026, 11:21 · report de9b26ea-57d7 · anonymous and shareable Run a new comparison