Skip to main content

Sunways STT-30KTL-SE

30 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
30.00
Strong · top 7%
Euro eff. (%)
98.2
Strong · top 20%
MPPT
2
Typical · median 2
Max DC (V)
1100
Strong · top 19%
Weight (kg)
27.4
Strong · 10.6 kg below median
Warranty (yrs)
-
Not published

The STT 15-30 kW series delivers three-phase on-grid inverters built for demanding commercial and industrial installations where reliability under harsh conditions matters most. An enclosure with an IP66 protection rating allows outdoor mounting without extra shelters, while integrated DC and AC surge protection combined with AFCI functionality minimizes the risk of failures and arc-fault fires. Inverters in this series operate flawlessly under phase shifts and harmonic grid distortions, making them a solid choice where power quality tends to be unstable. With configurations offering one or two MPPT trackers and support for up to 150% PV array oversizing, designers gain significant freedom in matching module capacity to inverter power, improving the overall economics of the investment. An additional 10 percent continuous output overload capacity lets installers capture momentary generation surges without losing energy. Commissioning and remote monitoring run through the Sunways Portal app, with support for WiFi, LAN, GPRS and RS485 connectivity plus remote firmware upgrades. It's a solution for installers looking for a compact, weather-resistant three-phase inverter for mid-power rooftop and ground-mount systems.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.2% 98.0% Strong · top 20% 67
MPPT trackers 2 2 Typical 168
Max DC input voltage 1100 V 1000 V Strong · top 19% 1
Weight per kW 0.9 1.8 Strong · top 7% 43
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 30 kW Continuous output
Max AC power 33.00 kW Short-term output above the rating
Max apparent power 33.00 kVA
Phases Three-phase
Nominal AC voltage 400 V
Max AC current 47.8 A
Grid frequency 50 Hz
Power factor 0.8 leading ... 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC voltage 1100 V Caps the string length
MPPT voltage range 200 to 950 V
Start-up voltage 180 V
MPPT trackers 2 2 strings each
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
European efficiency 98.2 % Weighted across part loads
Max efficiency 98.6 % Best single operating point
Dimensions 410 × 550 × 199 mm Height × width × depth
Weight 27.4 kg 0.9 kg per kW
Enclosure IP66
Cooling forced-air
Noise 40 dB
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 3000 m
Interfaces Wi-FiEthernetDisplay
Protocols RS485WiFiGPRSLAN
Protection AFCIDC switchSurge protection

Pros and cons

5 positive · 2 caution
What owners get
High efficiency and strong Euro-efficiency rating

Maximum efficiency of the STT 15-30kW series reaches 98.6%, with a Euro (weighted) efficiency of 98.2% that better reflects real-world operating conditions - figures comparable to Tier-1 commercial inverters such as Huawei SUN2000 or Sungrow SG series in the same power range.

IP66 enclosure for outdoor installation

The IP66-rated enclosure allows outdoor mounting without additional canopy or shelter, which sets the series apart from many competing commercial models rated only IP54/IP55 that require extra weather protection.

Up to 150% DC oversizing and AC overload capability

Support for DC input power up to 150% of the inverter's rated AC output, combined with a continuous 10% AC overload capability (up to 110% per manufacturer data), improves generation utilization and project economics at lower DC/AC ratios.

Built-in AFCI and surge protection for fire safety

Integrated AFCI (arc-fault circuit interrupter) on the DC side, combined with DC and AC surge protection, reduces arc-fault fire risk - a feature less commonly standard at this power class and often offered only as a premium option by competitors.

Flexible connectivity and remote monitoring

Support for WiFi, LAN, GPRS and RS485, along with the Sunways Portal app and remote firmware updates, simplifies fleet management without requiring on-site service visits.

Trade-offs
Limited field track record for the brand

Launched in 2022 (with the refreshed SE/SE-S variants unveiled in 2024), the series lacks the multi-year field history of established Tier-1 manufacturers such as Huawei, SMA, or Sungrow, which can matter when assessing long-term reliability for large commercial projects.

Dependence on a proprietary monitoring platform

Remote monitoring relies on the dedicated Sunways Portal app rather than an open API or integration with popular third-party SCADA platforms (e.g., SolarEdge Monitoring, Huawei FusionSolar OpenAPI), which can limit flexibility when integrating with an existing fleet management system.

Alternatives

All Sunways inverters
Inverter Power Euro eff. MPPT Weight Difference
Sunways STT-30KTL-SE 30 kW 98.2% 2 27.4 kg You are here
MID 30KTL3-X2 (Pro.E) 30 kW 98.6% 3 24.0 kg +0.4 pp efficiency, +1 MPPT, 3.4 kg lighter
MID 30KTL3-X 30 kW 98.5% - 29.5 kg 2.1 kg heavier
MID 30KTL3-X2-1 30 kW 98.5% - 31.0 kg 3.6 kg heavier
GW30K-MT 30 kW 98.5% - 40.0 kg 12.6 kg heavier
PRO30T-S3 30 kW 98.5% 2 20.0 kg 7.4 kg lighter
XG30KTR 30 kW 98.5% - 30.0 kg 2.6 kg heavier
HYX-S30K-LT 30 kW 98.5% - 44.0 kg 16.6 kg heavier
SUN2000-33KTL-A 30 kW 98.4% 4 62.0 kg +2 MPPT, 34.6 kg heavier

About the STT Series series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Can Sunways STT series inverters (15-30 kW) be installed outdoors without an additional canopy or enclosure?
Yes, STT series inverters feature an IP66-rated enclosure, meaning full dust-tightness and protection against water jets from any direction. This allows the unit to be mounted on a building facade, ground-mount structure, or any open outdoor location without building a rain shelter, simplifying the project and reducing installation costs.
How many PV modules can be connected to an STT inverter relative to its rated power?
The STT series supports PV array oversizing up to 150% of the inverter's rated power. In practice, a 20 kW inverter can accept up to 30 kWp of modules. This extra module capacity is beneficial since panels rarely operate at full irradiance, improving annual energy yield and shortening the investment payback period.
Can a Sunways STT inverter handle an unstable grid, such as one with harmonic distortion?
Yes, STT series inverters are designed to operate under poor grid power quality. They tolerate phase shifts and harmonic distortion without losing stable operation, which is important for industrial installations connected to weaker or heavily loaded grid lines.
What does the AFCI function do on STT inverters, and does it actually improve installation safety?
AFCI is a DC-side arc fault detection function that identifies potential arcing, for example from a damaged connector or worn cable insulation. The inverter continuously monitors the current waveform and automatically disconnects the array if arcing is detected. Combined with built-in DC and AC surge protection, this significantly reduces fire risk, especially in large rooftop and ground-mount installations.
Can an STT inverter be monitored remotely without a wired internet connection on site?
Yes, STT inverters support several communication options: WiFi, LAN, GPRS, and RS485. If no wired network is available on site, a GPRS module with a SIM card can be used instead. Data is sent to the Sunways Portal app, where production and operating status can be checked from anywhere, and the inverter firmware is updated remotely.
Does the STT inverter make use of short-term power spikes from the panels, or does it clip them?
STT inverters offer 10% continuous output overload capacity, allowing them to make better use of temporary generation surges, for example on cool, sunny days when panels perform above nominal rating. This reduces power clipping losses and increases annual energy yield from the system.