Sunways STT-30KTL-LV

Sunways STT-30KTL-LV

30 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
30.00
Strong · top 7%
Euro eff. (%)
98.3
Strong · top 11%
MPPT
4
Strong · top 6%
Max DC (V)
600
Weak · bottom 8%
Weight (kg)
42.0
Typical · median 38.0 kg
Warranty (yrs)
-
Not published

The STT LV series comprises three-phase grid-tied inverters from Sunways in the 15-37.5 kW power range, built for commercial and industrial installations where both yield and resilience under demanding conditions matter. Thanks to four independent MPPT trackers with dual DC input per tracker, the series effectively reduces losses caused by PV string mismatch, delivering a real boost in energy harvest even under uneven panel irradiance. The aluminum alloy enclosure and IP66 protection rating allow installation in environments with high humidity and dust exposure, while the wide operating temperature and altitude range make the unit a versatile choice regardless of location. The inverters feature integrated surge protection for both DC and AC circuits, minimizing the risk of failure during grid instability or lightning events. A transformerless topology combined with a maximum efficiency of up to 98.8% ensures low conversion losses and a faster return on investment. Remote string-level monitoring along with support for both wired and wireless communication simplify maintenance and firmware updates without an on-site visit, a significant advantage for installers managing multiple sites.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.3% 98.0% Strong · top 11% 38
MPPT trackers 4 2 Strong · top 6% 1
Max DC input voltage 600 V 1000 V Weak · bottom 8% 539
Weight per kW 1.4 1.8 Typical 184
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 30 kW Continuous output
Max AC power 33.00 kW Short-term output above the rating
Max apparent power 33.00 kVA
Phases Three-phase
Nominal AC voltage 220 V
Max AC current 86.6 A
Grid frequency 50 Hz
Power factor 0.8 leading...0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 48.00 kW DC/AC ratio 1.60
Max DC voltage 600 V Caps the string length
MPPT voltage range 180 to 550 V
Start-up voltage 180 V
MPPT trackers 4 2 strings each
Max input current per MPPT 32.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 40.0 A Must exceed the panel's Isc
European efficiency 98.3 % Weighted across part loads
Max efficiency 98.8 % Best single operating point
Dimensions 400 × 600 × 270 mm Height × width × depth
Weight 42.0 kg 1.4 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 3000 m
Interfaces Wi-FiEthernetDisplay
Protocols RS485WiFiGPRSLAN
Protection AFCIDC switchSurge protection

Pros and cons

5 positive · 3 caution
What owners get
Four independent MPPT trackers

Each of the four MPPT trackers has a dual DC input, allowing independent optimization of differently oriented or partially shaded strings. In commercial installations with complex roof geometry, this translates into a measurably higher energy yield compared to inverters with only 2-3 MPPT channels.

IP66 ingress protection rating

The aluminum alloy enclosure rated IP66 allows installation in high-humidity and dusty environments without additional shelter, a higher standard than the common IP65 rating in this segment, easing installation on industrial sites.

Peak efficiency of 98.8%

The transformerless topology combined with a peak efficiency of 98.8% (European efficiency around 98.3% per publicly available manufacturer data) reduces conversion losses, shortening payback time for 15-37.5 kW installations.

Integrated DC/AC surge protection

Built-in surge protection on both DC and AC sides lowers the risk of damage from lightning strikes or unstable grid conditions, relevant for ground-mounted and industrial-site installations exposed to voltage spikes.

String-level remote monitoring

String-level monitoring combined with wired and wireless communication enables diagnostics and firmware updates without an on-site service visit, cutting maintenance costs for installers managing multiple sites.

Trade-offs
Inconsistent and unclear warranty terms

Publicly available Sunways documents show discrepancies in warranty length across markets - 12 years (144 months) in Australia for the STT 4-25K series, but only 5 years per the manufacturer's .eu site. The lack of a unified, transparent warranty policy makes comparison with competitors like Huawei or Sungrow, which clearly communicate a global 10-year standard, difficult.

No confirmed BNEF Tier 1 listing

Unlike competitors such as GoodWe, Huawei, or SINEXCEL, no confirmation was found of Sunways appearing on the BloombergNEF Tier 1 Power Inverter list, an industry bankability indicator relied upon by investors and lenders financing commercial projects.

Reported service support issues

An independent Australian review outlet (SolarQuotes) documented a negative customer experience with Sunways warranty support, leading it to drop the brand from its recommended list - a relevant risk factor for commercial installations requiring responsive after-sales service.

Alternatives

All Sunways inverters
Inverter Power Euro eff. MPPT Weight Difference
Sunways STT-30KTL-LV 30 kW 98.3% 4 42.0 kg You are here
MID 30KTL3-X2 (Pro.E) 30 kW 98.6% 3 24.0 kg -1 MPPT, 18.0 kg lighter
MID 30KTL3-X 30 kW 98.5% - 29.5 kg 12.5 kg lighter
MID 30KTL3-X2-1 30 kW 98.5% - 31.0 kg 11.0 kg lighter
GW30K-MT 30 kW 98.5% - 40.0 kg 2.0 kg lighter
PRO30T-S3 30 kW 98.5% 2 20.0 kg -2 MPPT, 22.0 kg lighter
XG30KTR 30 kW 98.5% - 30.0 kg 12.0 kg lighter
HYX-S30K-LT 30 kW 98.5% - 44.0 kg 2.0 kg heavier
SUN2000-33KTL-A 30 kW 98.4% 4 62.0 kg 20.0 kg heavier

About the STT LV series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the maximum efficiency of the Sunways STT LV inverters and what does it mean for my system?
The STT LV series inverters reach a maximum efficiency of 98.8%, achieved through a transformerless topology. This means minimal energy loss during DC to AC conversion, so more of the generated power actually reaches the grid or load. In practice, this translates into a faster return on investment, especially for high-power commercial installations.
Are STT LV inverters suitable for installations with PV strings facing different directions or tilt angles?
Yes, the STT LV series features four independent MPPT trackers, each with dual DC inputs. This allows strings with different orientation, tilt angle, or shading levels to be connected without a significant loss in yield. This design is particularly useful for industrial and commercial sites, where roofs often have irregular geometry.
Can the Sunways STT LV inverter be installed outdoors in harsh weather conditions?
Yes, the aluminum alloy enclosure has an IP66 protection rating, providing full resistance to dust and strong water jets. The inverter can be installed in environments with high humidity and dust levels, and its wide operating temperature and altitude range make it suitable for installation regardless of location, including open industrial sites.
What surge protection does the STT LV inverter have against power spikes and lightning strikes?
STT LV series inverters include integrated surge protection on both the DC and AC circuits. This minimizes the risk of electronics damage from grid voltage spikes or nearby lightning strikes. This safeguard matters in commercial installations, where an inverter failure means tangible production downtime and financial losses.
Does servicing an STT LV inverter require an on-site technician visit?
Not always. STT LV inverters support remote per-string monitoring along with wired and wireless communication, allowing diagnostics and firmware updates to be performed remotely. For installers managing multiple sites, this is a major advantage, reducing costly service visits and enabling faster response to any operating issues.
What size PV installations is the Sunways STT LV series designed for?
The STT LV series includes three-phase inverters ranging from 15 to 37.5 kW, making it a dedicated solution for commercial and industrial installations, such as production halls, warehouses, or office buildings. It is not intended for typical residential prosumer microinstallations, which use inverters of much lower power.