Skip to main content

SRNE IESP500UH3

50 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
50.00
Typical for its class
Euro eff. (%)
97.0
Weak · bottom 2%
MPPT
4
Typical · median 4
Max DC (V)
1000
Typical · median 1100 V
Weight (kg)
98.0
Weak · 23.0 kg above median
Warranty (yrs)
5
Typical · median 5 yrs

The SRNE IESP series is a line of three-phase hybrid solar storage inverters rated at 50-60 kW, built for commercial and industrial installations where configuration flexibility and ruggedness under demanding conditions come first. The series stands out with 4 independent MPPT trackers, letting installers combine different roof orientations or PV module types without sacrificing energy yield. It also supports DC oversizing up to 1.6x, allowing a larger PV array than standard inverters in this class permit, boosting production during the morning and afternoon hours. A key advantage is the ultra-wide battery voltage range (150-850V DC), which simplifies battery storage selection regardless of manufacturer or cell technology. The IESP also handles fully unbalanced three-phase loads, making it a practical choice for sites with uneven load distribution across phases. On top of that, the inverter supports generator input, ensuring continuous operation even during extended grid outages. An IP65-rated enclosure and DC arc-fault detection add further safety for outdoor installations. It's a solution built for PV+BESS integrators seeking scalability, through parallel operation of up to 9 units, and reliability in a single device.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.0% 98.2% Weak · bottom 2% 394
MPPT trackers 4 4 Typical 104
Max DC input voltage 1000 V 1100 V Typical 298
Weight per kW 2.0 1.2 Weak · bottom 11% 460
Warranty 5 yrs 5 yrs Typical 45
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 50 kW Continuous output
Max apparent power 60.00 kVA
Phases Three-phase
Nominal AC voltage 480 V
Max AC current 72.3 A
Grid frequency 50 Hz Range 50/60Hz ±0.3Hz
Power factor 0.8 leading to 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 88.00 kW DC/AC ratio 1.76
Max DC voltage 1000 V Caps the string length
MPPT voltage range 150 to 850 V
Start-up voltage 160 V
MPPT trackers 4
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 60.0 A Must exceed the panel's Isc
European efficiency 97.0 % Weighted across part loads
Max efficiency 97.6 % Best single operating point
Battery port Yes
Battery voltage 150-850Vdc
Max charge current 80.0 A
Max discharge current 80.0 A
Grid-forming Yes
Dimensions 1011 × 622 × 343 mm Height × width × depth
Weight 98.0 kg 2.0 kg per kW
Enclosure IP65
Cooling forced-air
Noise 65 dB
Operating temperature -40 to 60 °C
Max humidity 100 %
Interfaces Wi-FiDisplay
Protocols RS485CANUSBDry Contact
Protection AFCISurge protection
Warranty 5 years Standard manufacturer cover
Certifications UL 1741-2021 (UL1741SB)CSA C22.2 No 107.1-16IEEE 1547-2018 & 1547a-2020 & 1547.1-2020 (SRD V2.0)UL 1741 CRD-PCSUL1699BCECSGIPCSIP

Pros and cons

5 positive · 2 caution
What owners get
4 independent MPPT trackers

Four MPPT inputs allow combining different roof orientations or PV module types without energy yield loss, an edge over competing hybrids in the 50-60 kW class, where 2-3 trackers are often the standard.

DC oversizing up to 1.6x

A DC/AC ratio of up to 1.6x allows connecting significantly more PV capacity than typical inverters in this power class permit, boosting energy production during morning and afternoon hours and better utilizing limited AC grid connection capacity.

Ultra-wide 150-850V DC battery voltage range

The 150-850V DC range notably exceeds the typical 200-800V found in competing products, easing integration of energy storage systems from different manufacturers and cell technologies without extra DC/DC converters.

Fully unbalanced three-phase load support

Support for fully unbalanced three-phase loads means the installation doesn't require load balancing across phases - a key advantage for commercial and industrial sites with uneven power draw distribution.

Scalability up to 9 parallel units

Parallel operation of up to 9 inverters enables building PV+BESS systems up to roughly 540 kW from a single product series, reducing integration costs for large C&I installations.

Trade-offs
No BNEF Tier 1 standing

SRNE, founded in 2009, does not appear on the BNEF Tier 1 inverter ranking, unlike Huawei, Sungrow, or SMA. For institutional investors requiring project bankability, this may complicate financing for large C&I installations.

Limited field track record in the 50-60 kW C&I segment

The IESP500SH3/550SH3/600SH3 models are only documented from 2025 onward (EU manual V00, August 2025), meaning a short field reference period compared to competitors with years of track record in the commercial hybrid segment.

Alternatives

All SRNE inverters
Inverter Power Euro eff. MPPT Weight Difference
SRNE IESP500UH3 50 kW 97.0% 4 98.0 kg You are here
50M1-HYB 50 kW 98.3% - 102.0 kg +1.3 pp efficiency, 4.0 kg heavier
50M1-HYA 50 kW 98.3% - 72.0 kg +1.3 pp efficiency, 26.0 kg lighter
AF50K-TH 50 kW 98.3% 4 70.0 kg +1.3 pp efficiency, 28.0 kg lighter
H3-50-Plus 50 kW 98.1% - 115.0 kg +1.1 pp efficiency, 17.0 kg heavier
P3-50-Plus 50 kW 98.1% - 115.0 kg +1.1 pp efficiency, 17.0 kg heavier
HP3-50KS1 50 kW 98.0% 5 80.0 kg +1.0 pp efficiency, +1 MPPT, 18.0 kg lighter
HYX-H50K-ET 50 kW 98.0% - 95.0 kg +1.0 pp efficiency, 3.0 kg lighter
GW50K-ET-10 50 kW 97.8% - 65.0 kg +0.8 pp efficiency, 33.0 kg lighter

About the IESP series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How does the 1.6x DC oversizing in SRNE IESP differ from standard inverters?
Typical hybrid inverters allow PV module power to exceed rated inverter power by only about 1.2-1.3x. SRNE IESP allows oversizing up to 1.6x, so a 50 kW inverter can accept up to 80 kW of PV modules. This boosts energy yield during lower-irradiance periods, such as morning and afternoon, helping the system pay back faster.
What types of energy storage batteries can be connected to SRNE IESP?
The inverter supports an ultra-wide battery voltage range of 150-850V DC, allowing it to work with energy storage systems from various manufacturers and cell technologies, including LiFePO4. This flexibility is useful when retrofitting existing installations or reusing batteries already on site, without needing storage dedicated to one specific inverter model.
Can SRNE IESP handle an installation with unbalanced load across phases?
Yes, the IESP series supports fully unbalanced three-phase loading, meaning each phase can carry a different load without restrictions imposed by the inverter. This is a key advantage for commercial and industrial sites where single-phase loads, such as lighting or small equipment, rarely distribute evenly across all three phases.
Does the SRNE IESP inverter keep running during an extended grid outage?
Yes, IESP supports generator input, ensuring continuous operation even during prolonged grid power outages. This is especially important for industrial and commercial sites, where downtime caused by power interruptions can halt production or disrupt critical systems.
How many SRNE IESP inverters can be connected in one installation?
The IESP series supports parallel operation of up to 9 units, allowing PV+BESS systems to scale well beyond a single 50-60 kW unit. This is designed for commercial and industrial integrators planning installations of several hundred kilowatts without changing the hardware platform.
Is the SRNE IESP enclosure suitable for outdoor installation?
Yes, the inverter has an IP65 rating, providing full protection against dust and water jets from any direction, so it can be mounted outdoors without an additional canopy. It also includes DC arc-fault detection, increasing safety for installations exposed to weather conditions and temperature fluctuations.