Skip to main content
Solplanet ASW15K-LT-G2 Pro

Solplanet ASW15K-LT-G2 Pro

15 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
15.00
Weak · bottom 17%
Euro eff. (%)
98.2
Strong · top 20%
MPPT
2
Typical · median 2
Max DC (V)
1100
Strong · top 19%
Weight (kg)
17.0
Strong · 21.0 kg below median
Warranty (yrs)
-
Not published

The Solplanet ASW LT-G2 Pro series comprises three-phase inverters ranging from 3 to 10 kW, built for residential and small commercial installations that need to run reliably for years. The compact wall-mount housing along with plug-in DC and AC connectors means installation can be completed with basic tools, while commissioning and setup are quick thanks to the dedicated Solplanet app. The series stands out for its wide MPP voltage range (150-1000 V) handled by two independent MPPT trackers, making it easier to match different string configurations. A maximum input current of up to 20 A makes these inverters particularly well suited to bifacial modules and large-area panels, while support for DC/AC oversizing up to 150% allows for higher energy yield without needing an additional inverter. The built-in ShadeSol shadow management feature reduces production losses in installations exposed to partial shading, such as from chimneys or trees. Thanks to its IP66-rated enclosure, the unit can be mounted outdoors without extra protection, and support for zero-export installations (via RS485 and approved smart meters) addresses the needs of prosumers constrained by grid regulations. This is a solution for installers looking for straightforward mounting combined with design flexibility.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.2% 98.0% Strong · top 20% 67
MPPT trackers 2 2 Typical 168
Max DC input voltage 1100 V 1000 V Strong · top 19% 1
Weight per kW 1.1 1.8 Strong · top 17% 99
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 15 kW Continuous output
Max apparent power 15.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 160 V to 300 V
Max AC current 24.0 A
Grid frequency 50 Hz Range 45 Hz to 55 Hz
Power factor 0.8 leading to 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 22.50 kW DC/AC ratio 1.50
Max DC voltage 1100 V Caps the string length
MPPT voltage range 150 to 1000 V
Start-up voltage 180 V
MPPT trackers 2 2 strings each
Max input current per MPPT 32.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 48.0 A Must exceed the panel's Isc
European efficiency 98.2 % Weighted across part loads
Max efficiency 98.6 % Best single operating point
Dimensions 435 × 503 × 183 mm Height × width × depth
Weight 17.0 kg 1.1 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 3000 m
Interfaces Wi-FiEthernet
Protocols RS485Wi-FiLAN4G
Protection DC switchSurge protection
Certifications CEEN50549IEC62109IEC62116IEC61727IEC61683IEC60068IEC61000AS/NZS4777C10/C11

Pros and cons

5 positive · 2 caution
What owners get
Wide MPPT voltage range (150-1000 V)

Two independent MPPT trackers with a 150-1000 V voltage window and up to 20 A maximum input current per tracker allow flexible string configuration, including bifacial and large-area modules, without extensive compatibility calculations.

DC/AC oversizing up to 150%

Support for connecting PV array power up to 150% of the inverter's rated AC output increases annual energy yield from the same unit, a meaningful cost advantage over competing models capped at 110-130% oversizing (e.g., some SMA Sunny Tripower variants).

Built-in ShadeSol shading management

The integrated shading-management algorithm minimizes production losses from partial shading (e.g., chimneys or trees) without requiring additional module-level power optimizers.

IP66 enclosure for unprotected outdoor mounting

IP66 ingress protection allows outdoor wall mounting without an extra protective canopy, reducing installation time and material costs compared to IP65-rated units.

Native zero-export support

RS485 integration with certified energy meters enables zero-export operation without external controllers, addressing grid-export restrictions placed on prosumers in several EU markets.

Trade-offs
Standard 10-year warranty, not lifetime

Base warranty coverage is 10 years, with extensions to 15-20 years sold as a paid add-on typically available only within 2 years of shipment. Some tier-1 competitors (e.g., Huawei, Growatt in select series) offer a longer base warranty with no extra charge.

Only 2 MPPT trackers on most 3-10 kW models

Two MPPT trackers limit design flexibility for complex installations with multiple roof orientations, compared to rival three-phase inverters in this segment that offer 3-4 independent trackers.

Inverter Power Euro eff. MPPT Weight Difference
Solplanet ASW15K-LT-G2 Pro 15 kW 98.2% 2 17.0 kg You are here
MID 15KTL3-X 15 kW 98.6% 2 23.0 kg +0.4 pp efficiency, 6.0 kg heavier
XG15KTR1-S 15 kW 98.5% 2 13.5 kg 3.5 kg lighter
HYX-S15K-LT 15 kW 98.5% - 44.0 kg 27.0 kg heavier
SG15KTL-M 15 kW 98.3% 2 24.0 kg 7.0 kg heavier
SUN2000-15KTL-M2 15 kW 98.3% 2 25.0 kg 8.0 kg heavier
SUN2000-15KTL-M0 15 kW 98.3% 2 25.0 kg 8.0 kg heavier
STT-15KTL-LV 15 kW 98.3% 4 42.0 kg +2 MPPT, 25.0 kg heavier
BNT015KTL 15 kW 98.2% 2 17.0 kg Similar on paper

About the ASW LT-G2 Pro series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the benefit of having two MPPT trackers in the Solplanet ASW LT-G2 Pro inverters?
The ASW LT-G2 Pro inverters feature two independent MPPT trackers covering an MPP voltage range of 150-1000 V. This allows two separate module strings with different tilt, azimuth, or shading conditions to be connected, each optimized at its own maximum power point. It increases design flexibility, especially for roofs with irregular geometry or installations with panels facing different directions.
Is the Solplanet ASW LT-G2 Pro inverter suitable for bifacial solar panels?
Yes, the maximum input current of up to 20 A per MPPT tracker makes the inverter well-suited for bifacial modules and large-area panels, which generate higher currents than standard monofacial modules. This allows full utilization of the additional energy reflected onto the rear side of the panel without risking exceeding the inverter's input ratings.
What is the ShadeSol function in Solplanet inverters, and is it worth relying on?
ShadeSol is a built-in shading management function that minimizes energy production losses in installations exposed to partial shading, such as from chimneys, vents, or nearby trees. It is particularly useful on roofs where full sun exposure for all modules throughout the day isn't possible, as it reduces losses caused by uneven lighting across panel strings.
Can the ASW LT-G2 Pro inverter be installed outdoors?
Yes, the IP66-rated enclosure allows outdoor installation without the need for an additional protective cover or canopy. The inverter resists dust and powerful water jets, making it suitable for mounting on building facades, unheated garages, or outbuildings exposed to weather conditions.
What does DC/AC oversizing up to 150% mean, and what is its benefit?
This means the installed PV panel capacity can be up to 50% higher than the inverter's rated AC power, e.g., a 10 kW inverter can be paired with up to 15 kW of panels. This configuration increases total energy yield, particularly during morning and afternoon hours and periods of lower irradiance, without needing to purchase a second, additional inverter.
Do Solplanet ASW LT-G2 Pro inverters support zero-export installations?
Yes, the series supports the zero-export function via an RS485 interface working with certified energy meters. This is useful for prosumers who, due to grid limitations or utility agreements, cannot export surplus energy to the public grid and must limit export to zero or a set threshold.