The ASW LT series is a lineup of three-phase inverters built for large commercial and industrial installations, where reliability under demanding operating conditions matters just as much as raw performance. These inverters stand out with string-level management, allowing installers and operators to precisely monitor each section of the array and quickly identify any drop in generation. Thanks to the high current capacity of their MPPT inputs, the series pairs well with bifacial modules and large-format panels, making it an attractive choice for projects designed to maximize energy yield. The ShadeSol function improves energy generation under partial shading or uneven irradiance, which matters on industrial rooftops with obstacles like chimneys or HVAC units. Its IP66-rated enclosure allows installation both indoors and outdoors without the need for additional protection against moisture or dust. Intelligent arc fault circuit interrupter (AFCI) detection and a built-in DC switch significantly raise the safety level during operation. The inverter is engineered for fast installation using standard tools, reducing installation time and labor costs for EPC contractors and commercial investors alike.
Ranking
Specifications
Pros and cons
Each MPPT input (up to 10 on the 75-110 kW models) is monitored independently, enabling precise identification of generation losses at the individual array section level rather than the whole inverter.
The ASW LT series spans from 3 kW (G2 Pro) to 150 kW (ASW150K-LT), allowing a single technology platform to cover both small commercial systems and large industrial PV plants.
The 75-110 kW models reach a maximum efficiency of 98.6% and a European efficiency of 98.4%, a result competitive with other Tier-1 inverters in this power class.
The IP66 protection rating allows indoor and outdoor installation without extra moisture or dust shielding, while ShadeSol reduces generation losses under partial shading, as confirmed in manufacturer materials for the 80-110K LT and 125K LT models.
Arc-fault circuit interruption (AFCI) and an integrated DC disconnect increase operational safety, standard on the G2 Pro models (e.g. 10 kW) and on the 80-150 kW series.
AFCI is standard on smaller G2 Pro models (e.g. 10 kW) and on the ASW 125K LT, but is listed as optional in documentation for the 75-110 kW series, requiring configuration verification when ordering a specific model.
The ASW LT series spans multiple generations (G2, G2 Pro, G3) with numerous datasheet revisions for the same models issued between 2020 and 2026, which can create ambiguity about current technical parameters when selecting a specific variant.
Alternatives
About the ASW LT series
These answers cover the whole series. Where a figure differs, the specification above is this model's own.