Skip to main content

Solectria XGI 1500-200/200-480

200 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
200.00
Typical for its class
Euro eff. (%)
-
Not published
MPPT
1
Weak · bottom 10%
Max DC (V)
1500
Strong · top 23%
Weight (kg)
131.5
Typical · median 99.0 kg
Warranty (yrs)
5
Typical · median 5 yrs

The SOLECTRIA XGI 1500-250 series comprises transformerless, utility-scale string inverters built for the largest solar plants, where power density, lower BoS costs, and overall plant yield are the deciding factors. Thanks to SiC technology used in the key switching components, these units reduce conversion losses and sustain high loads without excessive thermal buildup. A defining feature of the series is its high DC oversizing ratio, reaching up to 2.86, letting installers pair more module capacity with each inverter and push the project's LCOE closer to its optimal point without adding extra units. For projects using modules prone to potential-induced degradation, a functionally grounded DCG variant is available, eliminating PID risk without compromising system performance. The series has undergone an advanced cybersecurity analysis, a key consideration for plant operators connected to public grids and subject to regulatory requirements. The units are designed and manufactured in the USA in compliance with the Buy America Act, making them an attractive option for federally funded projects. It's a solution for developers and EPCs seeking reliability, configuration flexibility, and alignment with US incentive programs.

Ranking

238 inverters from 100 to 500 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.5% Not published -
MPPT trackers 1 8 Weak · bottom 10% 145
Max DC input voltage 1500 V 1100 V Strong · top 23% 1
Weight per kW 0.7 0.7 Typical 115
Warranty 5 yrs 5 yrs Typical 5
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 200 kW Continuous output
Max apparent power 200.00 kVA
Phases Three-phase
Nominal AC voltage 600 V -12% to +10%
Max AC current 240.6 A
Grid frequency 60 Hz
Power factor 0.80 leading - 0.80 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 204.00 kW DC/AC ratio 1.02
Max DC voltage 1500 V Caps the string length
MPPT voltage range 750 to 1250 V
MPPT trackers 1 2 strings each
Max input current per MPPT 296.7 A Must exceed the panel's Imp
Max short-circuit current per MPPT 800.0 A Must exceed the panel's Isc
Max efficiency 99.0 % Best single operating point
CEC efficiency 98.5 % California Energy Commission weighting
Dimensions 750 × 1125 × 390 mm Height × width × depth
Weight 131.5 kg 0.7 kg per kW
Enclosure NEMA 4X / IP66
Noise 73 dB
Operating temperature -40 to 60 °C
Max humidity 95 %
Max altitude 4000 m
Interfaces Wi-FiEthernet
Protocols WiFiEthernetSunSpec Modbus TCP/IP
Protection AFCIDC switch
Warranty 5 years Standard manufacturer cover
Certifications UL 1741IEEE 1547UL 1699bRule 21UL 1741SBFCC Part 15 Subpart B Class ATÜV Rheinland

Pros and cons

5 positive · 2 caution
What owners get
SiC technology cuts conversion losses

Using SiC transistors in key switching components allows operation under high loads without excessive thermal rise, delivering higher DC/AC conversion efficiency than legacy IGBT-based utility-scale designs.

Industry-leading 2.86 DC oversizing ratio

A ratio of 2.86 is significantly above the typical 1.2-1.5 found on competing utility-scale string inverters (e.g., Sungrow, Huawei), letting EPCs load more modules per inverter, cut unit count per MW, and push LCOE closer to the optimum.

DCG variant eliminates PID risk

A dedicated functionally-grounded DC variant (DCG) enables safe operation with modules prone to potential-induced degradation, including compatibility with First Solar modules, without sacrificing system performance - an uncommon option at this power class.

US-made, Buy America Act compliant

Designed and manufactured in the USA, the series qualifies for federally funded programs and the domestic content bonus under the IRA, a meaningful competitive edge in the US market versus imported Asian inverters.

Advanced cybersecurity assessment

The series underwent a dedicated cybersecurity evaluation, relevant for operators of grid-connected utility plants subject to regulatory requirements (e.g., NERC CIP) - rarely found outside premium utility-scale manufacturers.

Trade-offs
Higher BoS complexity with string architecture

Compared to central inverters used in GW-scale projects, a 250 kVA string architecture requires more units, DC cabling and combiners per installed MW, which can raise installation costs and commissioning time on the largest farms.

Limited brand recognition outside the US

Solectria (Yaskawa) holds a far smaller global market share in utility-scale than leaders like Huawei or Sungrow, which can affect perceived project bankability with investors and insurers outside the US market.

Inverter Power Euro eff. MPPT Weight Difference
Solectria XGI 1500-200/200-480 200 kW - 1 131.5 kg You are here
SUN2000-215KTL-H0 200 kW 98.8% 9 86.0 kg +8 MPPT, 45.5 kg lighter
SUN2000-215KTL-H3 200 kW 98.8% 3 86.0 kg +2 MPPT, 45.5 kg lighter
S6-GC3P200K07-HV-ND 200 kW 98.3% 7 105.0 kg +6 MPPT, 26.5 kg lighter
SG200HX-US 200 kW - 12 122.0 kg +11 MPPT, 9.5 kg lighter
SUN2000-188KTL-NHH0 187.5 kW - 6 114.0 kg -12.5 kW, +5 MPPT, 17.5 kg lighter
MAX 185KTL3-X HV 185 kW 98.7% - 95.0 kg -15.0 kW, 36.5 kg lighter
MAX 216KTL3-X HV 216 kW 98.7% - 95.0 kg +16.0 kW, 36.5 kg lighter
Sunny Highpower PEAK3 SHP 180-21 180 kW 98.9% 1 99.0 kg -20.0 kW, 32.5 kg lighter

About the XGI 1500-250 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the maximum power output of the Solectria XGI 1500-250 inverter?
The XGI 1500-250 series is a utility-scale string inverter with a nominal output of 250 kVA, operating at DC voltages up to 1500 V. Thanks to SiC switching components, the unit maintains high conversion efficiency even at full load, delivering a real energy yield gain on large-scale PV plants where every efficiency point matters.
What is the high DC oversizing ratio on the XGI 1500-250 and what does it mean for investors?
A DC oversizing ratio of up to 2.86 means far more PV module power can be connected per inverter than its nominal AC rating. In practice, this lets designers install fewer inverters for the same plant capacity, cutting BoS costs (cabling, switchgear, racking) and pushing LCOE closer to its optimal level without sacrificing system performance.
Is the Solectria XGI 1500-250 resistant to module PID degradation?
The standard version has no dedicated PID protection, but for projects using modules prone to potential-induced degradation, a variant with functional DC grounding (DCG) is available. It eliminates PID risk without reducing system performance, which matters for PERC or n-type modules sensitive to negative voltage to ground.
Does the XGI 1500-250 inverter meet Buy America Act requirements for federally funded projects?
Yes, the XGI 1500-250 series inverters are designed and manufactured in the USA in compliance with Buy America Act requirements. This is a key advantage for developers and EPCs executing federally funded projects or applying for U.S. support programs where component origin is a formal qualification criterion.
How does the XGI 1500-250 address cybersecurity for plants connected to the public grid?
The XGI 1500-250 series has undergone advanced cybersecurity analysis, which matters for operators of solar farms connected to the public grid and subject to critical infrastructure regulatory requirements. This is an added advantage when selecting a supplier for large utility-scale tenders.
What types of projects and DC voltage ranges best suit the Solectria XGI 1500-250?
The inverter is built for the largest utility-scale PV plants, operating within a DC voltage range up to 1500 V with a full-power MPPT window covering typical module string configurations. Its transformerless design reduces weight and installation cost, and its high power-to-cost density makes it well suited for developers and EPCs focused on maximizing productivity per megawatt.