Skip to main content
Solectria XGI 1500-125/150-UL

Solectria XGI 1500-125/150-UL

125 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
125.00
Typical for its class
Euro eff. (%)
-
Not published
MPPT
1
Weak · bottom 10%
Max DC (V)
1500
Strong · top 23%
Weight (kg)
122.0
Weak · 23.0 kg above median
Warranty (yrs)
5
Typical · median 5 yrs

The Solectria XGI 1500-166 series is a transformerless, utility-scale string inverter engineered for large-scale photovoltaic plants where every kilowatt-hour recovered from the solar array matters. The transformerless design helps cut conversion losses and reduces overall unit weight, which translates directly into a lower LCOE for the entire power plant. It addresses a common pain point for utility-scale investors: balancing high power density with field serviceability - an integrated DC disconnect and a weather-resistant enclosure significantly shorten installation and maintenance time. The series stands out with a wide MPPT voltage range, allowing flexible string configuration across different module types, including panels built on PERC or half-cut cell technologies, without sacrificing conversion performance. Compliance with UL1741SB and Rule 21 enables interconnection with grids requiring advanced grid-support functions, a key requirement for solar farms working with utilities in the US market. The XGI 1500-166 targets EPC contractors and developers building commercial and industrial installations measured in megawatts, where durability, low failure rates, and dependable warranty support are essential. It is built for projects where any interruption in energy production means a real financial loss.

Ranking

238 inverters from 100 to 500 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.5% Not published -
MPPT trackers 1 8 Weak · bottom 10% 145
Max DC input voltage 1500 V 1100 V Strong · top 23% 1
Weight per kW 1.0 0.7 Weak · bottom 5% 224
Warranty 5 yrs 5 yrs Typical 5
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 125 kW Continuous output
Max apparent power 150.00 kVA
Phases Three-phase
Nominal AC voltage 600 V -12% to +10%
Max AC current 144.0 A
Grid frequency 60 Hz
Power factor +/- 0.80 Adjustable
Harmonic distortion (THD) 3.0 %
Max DC input power 128.00 kW DC/AC ratio 1.02
Max DC voltage 1500 V Caps the string length
MPPT voltage range 860 to 1450 V
MPPT trackers 1
Max short-circuit current per MPPT 500.0 A Must exceed the panel's Isc
Max efficiency 98.9 % Best single operating point
CEC efficiency 98.5 % California Energy Commission weighting
Dimensions 750 × 1000 × 380 mm Height × width × depth
Weight 122.0 kg 1.0 kg per kW
Enclosure Type 4X
Noise 73 dB
Operating temperature -40 to 60 °C
Max humidity 95 %
Max altitude 3000 m
Installation Outdoor only
Interfaces Wi-FiEthernet
Protocols WiFiEthernetSunSpec Modbus TCP/IP
Protection AFCIDC switch
Warranty 5 years Standard manufacturer cover
Certifications UL1741SBIEEE 1547UL 1699b Photovoltaic Arc-Fault Circuit Protection Certified (-A models)Rule 21FCC Part 15 (Subpart B, Class A)

Pros and cons

5 positive · 1 caution
What owners get
High conversion efficiency at 99.0%

Peak efficiency of 99.0% and CEC weighted efficiency of 98.5% place the XGI 1500-166 in the upper tier of the 2017-era utility-scale segment, limiting DC/AC conversion losses in large-scale PV plants.

Transformerless design

The lack of a transformer reduces unit weight and energy losses compared to Solectria's older transformer-based inverters (e.g., the SGI 500/750XTM family), translating into lower plant LCOE and easier transport/installation on site.

Integrated DC disconnect and NEMA outdoor enclosure

A built-in DC disconnect and weatherproof enclosure shorten installation and maintenance time on large farms, reducing O&M costs.

UL1741SB and Rule 21 compliance

Certification for advanced grid-support (smart inverter) functions enables interconnection with utilities requiring active voltage and frequency management, a common requirement for U.S. utility interconnection agreements.

Still an active product line

Unlike older Solectria models (e.g., PVI 50-100kW, SGI 500XT), the XGI 1500-166 does not appear on Yaskawa-Solectria's discontinued-products list, meaning support and service documentation remain available.

Trade-offs
2017-era platform - older 1500V generation

The design dates back to 2017, while current tier-1 utility-scale leaders (e.g., Sungrow, Huawei, SMA) now offer units with higher power density per rack and comparable or higher peak efficiency (99.0-99.02%), which can make the XGI 1500-166 less competitive for new megawatt-scale projects.

Inverter Power Euro eff. MPPT Weight Difference
Solectria XGI 1500-125/150-UL 125 kW - 1 122.0 kg You are here
125 TL3 US-S 125 kW 99.0% 1 78.2 kg 43.8 kg lighter
125 TL3 125 kW 99.0% 1 78.2 kg 43.8 kg lighter
125 TL3-US 125 kW 98.7% 1 78.2 kg 43.8 kg lighter
125 NX3 M10 125 kW 98.7% - - Similar on paper
CL125E 125 kW 98.7% 1 75.0 kg 47.0 kg lighter
Argeno 125 125 kW 98.7% 10 90.0 kg +9 MPPT, 32.0 kg lighter
S5-GC125K-HV 125 kW 98.6% 10 91.0 kg +9 MPPT, 31.0 kg lighter
C6-125K-T12-40 125 kW 98.5% - 98.0 kg 24.0 kg lighter

About the XGI 1500-166 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the maximum power output and efficiency of the Solectria XGI 1500-166 inverter?
The XGI 1500-166 is a three-phase inverter with a rated output of 150 kW (166 kVA) at 600 VAC. Thanks to its transformerless design, it reaches a peak conversion efficiency of 99.0%, with a CEC weighted average efficiency of 98.5%. That translates into lower energy losses and higher yield compared to traditional transformer-based central inverters.
Can the XGI 1500-166 inverter be installed outdoors without an additional shelter?
Yes. The enclosure is made of powder-coated aluminum with a Type 4X rating, meaning it's protected against rain, dust, and corrosion. The unit is designed for field deployment on utility-scale PV sites without requiring extra protective canopies, reducing both installation time and project costs.
What is the MPPT voltage range, and does the XGI 1500-166 work with PERC or half-cut panels?
The MPPT operating range is approximately 860 to 1250 VDC, with a maximum input voltage of 1500 VDC. This wide range allows flexible string configuration across different module types, including PERC and half-cut cells, without sacrificing conversion efficiency. Installers can match string length to the project without risking voltage overruns.
Does the XGI 1500-166 meet the standards required for grid support functions in US utility interconnections?
Yes, the series is certified to UL1741SB and Rule 21, enabling advanced grid support functions such as voltage regulation and reactive power control. It also carries IEEE 1547, UL 1741, UL 1998, and FCC Part 15 certifications, which is essential for PV farms connecting to utilities that require compliance with modern grid interconnection standards.
How does the transformerless design of the XGI 1500-166 differ from a transformer-based inverter?
Removing the transformer cuts conversion losses and reduces the unit's weight to about 122 kg (270 lbs), easing transport and field installation. This design directly lowers the LCOE of the overall power plant since less energy is lost inside the inverter itself. An integrated DC disconnect also speeds up servicing by eliminating the need for separate external disconnect enclosures.
What kind of PV projects is the XGI 1500-166 best suited for?
The inverter targets EPC companies and investors building commercial and industrial installations in the megawatt range, where durability and low failure rates matter most. Its 150 kW unit power makes it easy to scale the inverter fleet to match plant capacity, and manufacturer warranty support minimizes the risk of costly production downtime.