Skip to main content

Solectria PVI 36TL

36 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
36.00
Weak · bottom 12%
Euro eff. (%)
-
Not published
MPPT
2
Weak · bottom 8%
Max DC (V)
1000
Typical · median 1100 V
Weight (kg)
56.5
Weak · bottom 24%
Warranty (yrs)
10
Strong · top 14%

The PVI TL series consists of transformerless three-phase string inverters from Solectria, built for commercial and industrial installations where fast deployment and reliable long-term operation matter most. A defining feature of the design is dual MPPT tracking, which lets two separate groups of strings be optimized independently even when they differ in orientation, roof pitch, or shading - a practical answer to energy losses on unevenly exposed arrays. The inverter includes an integrated, fused DC string combiner and DC arc-fault protection, removing the need for extra junction boxes and improving the fire safety of the whole system. Thanks to its compact, lightweight enclosure, the unit can be installed by a single technician without heavy equipment, significantly cutting rooftop or mechanical-room install time. Advanced DSP control and a well-engineered thermal design keep operation stable even under demanding heat conditions, while the built-in LCD display and Modbus communication simplify ongoing diagnostics. The PVI TL series is a strong fit for projects where investors prioritize low lifecycle operating and service costs, and it is backed by a 10-year warranty extendable to 15 or 20 years.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.2% Not published -
MPPT trackers 2 4 Weak · bottom 8% 243
Max DC input voltage 1000 V 1100 V Typical 298
Weight per kW 1.6 1.2 Weak · bottom 24% 395
Warranty 10 yrs 5 yrs Strong · top 14% 8
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 36 kW Continuous output
Phases Three-phase
Nominal AC voltage 480 V -12%/+10%
Max AC current 43.3 A
Grid frequency 60 Hz Range 59.3-60.5 Hz (adjustable 55-65 Hz)
Power factor Unity, >0.99 (±0.8 adjustable)
Harmonic distortion (THD) 3.0 %
Max DC input power 54.00 kW DC/AC ratio 1.50
Max DC voltage 1000 V Caps the string length
MPPT voltage range 180 to 950 V
Start-up voltage 300 V
MPPT trackers 2 4 strings each
Max input current per MPPT 35.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 60.0 A Must exceed the panel's Isc
Max efficiency 98.5 % Best single operating point
CEC efficiency 98.0 % California Energy Commission weighting
Dimensions 1001 × 600 × 232 mm Height × width × depth
Weight 56.5 kg 1.6 kg per kW
Enclosure Type 4
Noise 50 dB
Operating temperature -25 to 60 °C
Max humidity 95 %
Max altitude 4000 m
Interfaces Display
Protocols RS-485 Modbus RTU
Protection AFCIDC switch
Warranty 10 years Standard manufacturer cover
Certifications UL 1741IEEE 1547CSA C22.2#107.1FCC part 15 B

Pros and cons

5 positive · 3 caution
What owners get
Dual MPPT tracker

Two independent MPPT inputs allow independent optimization of string arrays with different orientation, tilt, or shading levels, reducing energy losses typical of commercial installations on complex rooftops.

Integrated DC combiner with arc-fault protection

A built-in, fused DC string combiner (e.g., 8 positions at 15A on PVI 14TL, 10 positions at 15/30A on PVI 28TL/36TL) along with factory DC arc-fault protection eliminates the need for separate combiner boxes and improves the installation's fire safety.

Compact, lightweight enclosure

The unit's low weight allows single-person installation without hoists or extra equipment, meaningfully cutting rooftop or technical-room labor time compared to transformer-based competitors of similar power.

Low THD and high output power quality

PVI 14TL documentation lists THD below 3% at rated load, a result that meets the requirements expected for commercial installations connected to low-voltage switchgear.

10-year standard warranty

The PVI 23TL/28TL/36TL/50TL/60TL models carry a 10-year manufacturer warranty, which at the series' launch (2013) matched the upper end of the market standard for commercial-class string inverters.

Trade-offs
Discontinued production, limited service availability

The PVI TL series has been discontinued (launched in 2013), and several models (e.g., PVI 20TL, 23TL) are listed as discontinued in current Yaskawa Solectria documentation. This presents a real long-term risk regarding spare parts and service support availability.

No confirmed 15-20 year warranty extension option

Yaskawa Solectria Solar's current warranty policy for the PVI 23TL, 28TL, 36TL, 50TL and 60TL models lists a standard 10-year term with extensions marked "Not Available", which calls into question the claimed option to extend coverage to 15 or 20 years.

Inconsistent specs across models and revisions

Technical specifications (DC voltage up to 600V on PVI 14TL vs. 1000V from PVI 20TL upward, combiner input count and ratings) vary between variants and datasheet revisions, requiring model-specific verification before use in a project.

Inverter Power Euro eff. MPPT Weight Difference
Solectria PVI 36TL 36 kW - 2 56.5 kg You are here
MID 36KTL3-X 36 kW 98.5% - 30.5 kg 26.0 kg lighter
GW36K-MT 36 kW 98.5% - 40.0 kg 16.5 kg lighter
XG36KTR 36 kW 98.5% - 32.0 kg 24.5 kg lighter
SUN2000-36KTL 36 kW 98.4% 4 62.0 kg +2 MPPT, 5.5 kg heavier
SUN2000-36KTL-M3 36 kW 98.4% 4 43.0 kg +2 MPPT, 13.5 kg lighter
V36 36 kW 98.4% - 42.0 kg 14.5 kg lighter
SG36CX-P2 36 kW 98.3% 4 40.0 kg +2 MPPT, 16.5 kg lighter
S5-GC36K 36 kW 98.3% - 42.1 kg 14.4 kg lighter

About the PVI TL series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Are Solectria PVI TL inverters still available for purchase?
The PVI TL series has been discontinued by Solectria and is no longer offered as a new product. Units may still be found on the secondary market or in distributor stock, but for new installations it is worth considering the manufacturer's current three-phase models instead. Service support and spare parts for the PVI TL may be limited, which should be factored in when using this series to expand an existing system.
What is the dual MPPT tracker in the Solectria PVI TL inverter for?
The dual MPPT tracker allows two separate strings of solar panels connected to the same inverter to be optimized independently. This is useful when panels are mounted on two roof slopes with different orientation, tilt angle, or shading levels. Each string group operates at its own optimal power point, reducing energy losses caused by uneven sun exposure and increasing the real-world yield of the installation.
Does the Solectria PVI TL inverter require a separate DC combiner box?
No, PVI TL inverters feature an integrated, fused DC string combiner built directly into the unit. This eliminates the need for a separate DC junction box on the roof or in the technical room, shortening installation time and reducing the number of components requiring wiring and later maintenance checks.
How does the PVI TL inverter protect the installation from fire hazards?
PVI TL series inverters include DC arc-fault protection, which detects dangerous arcing that can occur from damaged wiring or loose string connectors. The feature automatically disconnects the system when an arc is detected, significantly improving fire safety, particularly in commercial and industrial buildings where DC cable runs tend to be longer.
What is the warranty on Solectria PVI TL inverters, and can it be extended?
The standard manufacturer warranty on the PVI TL series is 10 years, with the option to extend coverage to 15 or 20 years. This matters particularly for commercial installations, where investors calculate operating costs over a long time horizon. Since the series has been discontinued, it's worth confirming extended warranty availability with the distributor before purchase.
Does installing the Solectria PVI TL inverter require extra equipment or two installers?
No, thanks to its compact and lightweight enclosure, the PVI TL can be installed by a single person without lifting equipment or other heavy tools. This significantly shortens work time on the roof or in the technical room compared to larger, heavier three-phase inverters of similar power, lowering labor costs for commercial installations.