Skip to main content
SolaX FTH125T-S3

SolaX FTH125T-S3

125 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
125.00
Typical for its class
Euro eff. (%)
98.4
Typical · median 98.5%
MPPT
6
Typical · median 8
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
72.0
Typical · median 99.0 kg
Warranty (yrs)
-
Not published

The FORTH G3 series comprises three-phase C&I inverters built for commercial and industrial installations, where reliability and ease of maintenance matter just as much as output. Thanks to SiC technology, these units are significantly lighter than competing solutions of similar power, which makes transport and installation on rooftops or in containerized PV farms noticeably easier. Remote string diagnostics via I-V curve scanning allows installers to detect faults without sending a service crew on-site, cutting operational costs meaningfully. The series also stands out with its removable, self-cleaning fan, which eliminates the need for manual cooling system maintenance. For investors working in demanding climates, the IP66 enclosure with C5 corrosion resistance is a key advantage, suited for coastal and industrial zones. FORTH G3 supports parallel operation of up to 10 units without an external EMS, greatly simplifying the scaling of large installations. An optional unbalanced three-phase output and support for automatic genset start-stop make this series a flexible choice for both standalone PV farms and hybrid systems paired with generators.

Ranking

238 inverters from 100 to 500 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.4% 98.5% Typical 96
MPPT trackers 6 8 Typical 109
Max DC input voltage 1100 V 1100 V Typical 113
Weight per kW 0.6 0.7 Typical 87
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 125 kW Continuous output
Max apparent power 125.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 220/380, 230/400, 277/480 a.c. V
Max AC current 189.4 A
Grid frequency 50 Hz Range 50 ± 5 / 60 ± 5 Hz
Power factor 0.8 lagging to 0.8 leading
Max DC input power 188.00 kW DC/AC ratio 1.50
Max DC voltage 1100 V Caps the string length
MPPT voltage range 160 to 1000 V
Start-up voltage 200 V
MPPT trackers 6 3 strings each
Max input current per MPPT 45.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 60.0 A Must exceed the panel's Isc
European efficiency 98.4 % Weighted across part loads
Max efficiency 98.8 % Best single operating point
Dimensions 673 × 942 × 316 mm Height × width × depth
Weight 72.0 kg 0.6 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Protocols RS485USBDRMDI/DOPLC
Protection AFCIDC switchSurge protection
Certifications IEC/EN 62109-1IEC/EN 62109-2IEC/EN 61000IEC 61727IEC 62116EN50549

Pros and cons

5 positive · 2 caution
What owners get
Reduced weight via SiC transistors

The use of SiC (silicon carbide) semiconductors cuts device weight by roughly 20% compared to IGBT-based designs of similar power, directly simplifying transport and one- or two-person installation on industrial roofs without a crane.

Remote I-V diagnostics without a site visit

Built-in I-V curve scanning per MPPT (30-60 second scan duration) enables remote detection of string faults, reducing costly service dispatches in large C&I installations typical of 1-5 MWp solar farms.

Parallel operation of up to 10 units without EMS

The ability to link up to 10 inverters in parallel without an additional Energy Management System (EMS) lowers electrical integration costs when scaling installations in the 800 kW - 1.25 MW range.

High efficiency up to 98.8%

The claimed maximum conversion efficiency of 98.8% is on par with parameters offered by segment leaders in C&I (e.g., Huawei, Sungrow) and limits energy losses during DC/AC conversion.

IP66 enclosure with C5 corrosion resistance

IP66 ingress protection combined with C5 corrosion resistance allows installation in coastal and industrial zones without an additional protective enclosure, an advantage over models with lower IP ratings (e.g., IP65) used by some competitors.

Trade-offs
Power range capped at 125 kW

The FORTH G3 series spans 80-125 kW models (FTH80T-S3 to FTH125T-S3), while competing C&I series (e.g., Huawei SUN2000-350KTL, Sungrow SG350HX) reach 320-350 kW per unit, requiring more inverters and combiner boxes for very large PV farms.

I-V scan input power limited to 16 kW per MPPT

The I-V diagnostic feature only operates reliably up to 16 kW input power per MPPT and under clear-sky conditions, limiting its diagnostic usefulness during overcast periods or heavily loaded strings.

Alternatives

All SolaX inverters
Inverter Power Euro eff. MPPT Weight Difference
SolaX FTH125T-S3 125 kW 98.4% 6 72.0 kg You are here
125 TL3 US-S 125 kW 99.0% 1 78.2 kg +0.6 pp efficiency, -5 MPPT, 6.2 kg heavier
125 TL3 125 kW 99.0% 1 78.2 kg +0.6 pp efficiency, -5 MPPT, 6.2 kg heavier
125 TL3-US 125 kW 98.7% 1 78.2 kg -5 MPPT, 6.2 kg heavier
125 NX3 M10 125 kW 98.7% - - Similar on paper
CL125E 125 kW 98.7% 1 75.0 kg -5 MPPT, 3.0 kg heavier
Argeno 125 125 kW 98.7% 10 90.0 kg +4 MPPT, 18.0 kg heavier
S5-GC125K-HV 125 kW 98.6% 10 91.0 kg +4 MPPT, 19.0 kg heavier
C6-125K-T12-40 125 kW 98.5% - 98.0 kg 26.0 kg heavier

About the FORTH G3 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How does remote string diagnostics work on SolaX FORTH G3 inverters, and does it replace on-site service?
FORTH G3 inverters use I-V curve scanning to remotely assess the condition of each PV string without a technician on site. The system detects voltage drops, module soiling, or connection faults and sends a report to the operator. As a result, a service crew is only dispatched when the diagnosis clearly indicates a required intervention, significantly cutting operational costs for C&I installations.
How many FORTH G3 units can be connected in parallel without an additional EMS?
The FORTH G3 series supports parallel operation of up to 10 units without requiring an external energy management system (EMS). The inverters communicate with each other automatically, which greatly speeds up design and commissioning for large industrial installations or PV plants. This approach reduces integration costs and shortens project timelines compared to systems that need extra control infrastructure.
Is the FORTH G3 suitable for coastal or heavy industrial installations?
Yes, the FORTH G3 enclosure carries an IP66 rating and C5 corrosion resistance, meaning full protection against dust and water jets plus resistance to aggressive environments, including salt mist and industrial pollutants. This makes the unit suitable for outdoor mounting in coastal zones, chemical plants, or heavy industry sites without needing additional protective enclosures.
What power range does the SolaX FORTH G3 series cover, and what installations is it suited for?
The FORTH G3 series is available in power ratings from 80 kW to 125 kW, placing it in the commercial & industrial (C&I) segment. Thanks to SiC technology, the units are lighter than comparable-power competing inverters, easing transport and installation on industrial rooftops and in containerized PV plants where crane access or mounting space is often limited.
Does the FORTH G3 inverter require regular cleaning of its cooling fan?
No, the FORTH G3 features a replaceable, self-cleaning fan that eliminates the need for manual cleaning of the cooling system. This design reduces service downtime and extends the lifespan of electronic components, since accumulated dust and debris are removed automatically. In practice, this lowers long-term maintenance costs, especially in dusty industrial environments.
Does the FORTH G3 support generator integration and unbalanced three-phase loads?
Yes, the FORTH G3 series supports automatic start and stop of a diesel generator, enabling smooth operation in hybrid systems combining solar PV with backup generation. An optional unbalanced three-phase output function is also available, allowing power delivery to loads with differing demand across phases. This flexibility makes the inverter well suited for industrial sites with uneven energy consumption profiles.