Skip to main content

Sofar Solar HYD-7.6K-LS1-PRO

7.6 kW Hybrid Single-phase Battery-ready
Datasheet PDF
Rated AC (kW)
7.60
Weak · bottom 14%
Euro eff. (%)
97.0
Weak · bottom 24%
MPPT
2
Typical · median 2
Max DC (V)
500
Weak · bottom 11%
Weight (kg)
24.0
Typical · median 28.0 kg
Warranty (yrs)
-
Not published

The Sofar Solar HYD-LS1-PRO series consists of single-phase hybrid inverters built to work with residential energy storage systems, combining PV inverter functionality and battery management in one compact unit. Thanks to dual MPPT inputs, the device tracks the maximum power point of two separate module strings independently, which matters in installations with panels facing different directions or where part of the roof is shaded - solving the energy-loss problem typical of simpler single-string inverters. The series supports low-voltage batteries, making integration with popular storage systems on the market easier and lowering deployment costs for installers. A key competitive advantage is its high overload resistance, which lets the inverter handle momentary load spikes caused by high-draw appliances such as heat pumps or air conditioners without issue. On top of that comes a wide operating temperature range, covering conditions from severe frost to high summer heat, making the unit a versatile choice regardless of mounting location - garage, basement, or outdoors. The HYD-LS1-PRO is well suited for single-family homeowners who want to maximize self-consumption of solar energy and protect themselves against power outages.

Ranking

1,093 inverters from 6 to 12 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.0% 97.5% Weak · bottom 24% 539
MPPT trackers 2 2 Typical 192
Max DC input voltage 500 V 800 V Weak · bottom 11% 828
Weight per kW 3.2 3.0 Typical 581
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 7.6 kW Continuous output
Max apparent power 8.40 kVA
Phases Single-phase
Nominal AC voltage 230 V 220/230/240V
Max AC current 38.0 A
Power factor 0.8 lagging - 0.8 leading
Harmonic distortion (THD) 3.0 %
Max DC input power 15.20 kW DC/AC ratio 2.00
Max DC voltage 500 V Caps the string length
MPPT voltage range 60 to 435 V
Start-up voltage 90 V
MPPT trackers 2
European efficiency 97.0 % Weighted across part loads
Max efficiency 97.6 % Best single operating point
Battery port Yes
Battery voltage 40-60V
Dimensions 540 × 335 × 220 mm Height × width × depth
Weight 24.0 kg 3.2 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -30 to 60 °C
Max humidity 95 %
Max altitude 4000 m
Interfaces Wi-FiEthernetBluetoothDisplay
Protocols RS485BluetoothWiFi4GLANCAN
Protection DC switchSurge protection

Pros and cons

5 positive · 2 caution
What owners get
Dual MPPT for installation flexibility

Two independent MPPT inputs (up to 32A each) allow the unit to handle two module strings with different orientation or partial shading without significant energy losses, an advantage over simpler single-string hybrids in this power class.

High overload tolerance (200%/10s)

The inverter withstands up to 200% of rated power for 10 seconds and charge/discharge current up to roughly 190-210A, safely handling the startup surge of heat pumps, air conditioners, or compressors without tripping protections.

Compatibility with popular low-voltage batteries

Support for 40-60V energy storage ranges simplifies integration with widely available LFP modules (e.g. Pylontech-type and similar) on the market, reducing deployment costs and install time for installers compared to high-voltage systems requiring dedicated storage units.

Wide operating temperature range (-30°C to 60°C)

An operating range of -30°C to 60°C enables outdoor mounting, unheated garages, or basements without additional room climate control, distinguishing the series from models restricted to temperature-controlled indoor spaces.

Compact 2-in-1 design

Integrating the PV inverter and battery management system into a single enclosure reduces the number of installation components compared to AC-coupled solutions, simplifying installation and limiting potential points of failure.

Trade-offs
Low-voltage battery architecture (40-60V)

Unlike newer high-voltage hybrids (e.g. 100-600V), the 40-60V architecture requires higher charging currents (up to ~190-210A) for comparable power, meaning thicker DC cabling and greater cable losses than in HV systems of similar capacity.

Limited availability of public technical data

The manufacturer does not publish a readily accessible full datasheet with warranty terms or a BMS-protocol battery compatibility list specifically for this series - unlike segment leaders (e.g. Huawei, Deye) where such materials are standard online, which can slow down component selection for installers.

Inverter Power Euro eff. MPPT Weight Difference
Sofar Solar HYD-7.6K-LS1-PRO 7.6 kW 97.0% 2 24.0 kg You are here
R7K6LNA 7.6 kW 97.8% 4 48.0 kg +0.8 pp efficiency, +2 MPPT, 24.0 kg heavier
H2-7.6K-LS2 7.6 kW 97.0% 2 35.0 kg 11.0 kg heavier
SUN-7.6K-SG05LP1-EU 7.6 kW 96.5% 2 24.0 kg -0.5 pp efficiency
SUN-7.6K-SG01LP1-EU 7.6 kW 96.5% 2 30.0 kg -0.5 pp efficiency, 6.0 kg heavier
SUN-7.6K-SG02LP2-US-AM2 7.6 kW 96.5% - 35.6 kg -0.5 pp efficiency, 11.6 kg heavier
SUN-7.6K-SG01LP1-US 7.6 kW 96.5% 2 30.0 kg -0.5 pp efficiency, 6.0 kg heavier
SUN-7.6K-SG06LP1-EU-BM3 7.6 kW 96.5% 3 23.7 kg -0.5 pp efficiency, +1 MPPT
SUN-7.6K-SG05LP1-EU-SM2 7.6 kW 96.5% 2 26.8 kg -0.5 pp efficiency, 2.8 kg heavier

About the HYD-LS1-PRO series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the power range of the Sofar Solar HYD-LS1-PRO inverter series?
The HYD-LS1-PRO series includes single-phase hybrid inverters with power ratings from roughly 3 to 8 kW, covering the needs of most single-family homes. This lets you match the inverter size to your PV array and household consumption without oversizing the system.
Can the HYD-LS1-PRO handle the startup surge of a heat pump or air conditioner?
Yes, the unit offers high overload tolerance, supporting up to 200% of rated power for short periods. This solves a common issue in homes with heat pumps or air conditioners, where compressor startup causes a brief power spike that could trip less robust inverters.
Which battery energy storage systems are compatible with the HYD-LS1-PRO?
The series supports low-voltage batteries, which greatly simplifies integration with popular energy storage systems on the market and lowers installation costs for installers. Before purchasing, it's still worth checking the manufacturer's compatibility list for your specific battery model to avoid BMS communication issues.
How does the dual MPPT input on the HYD-LS1-PRO differ from single-string inverters?
Two independent MPPT inputs allow the inverter to track the maximum power point for two separate PV strings simultaneously. This matters for arrays with panels facing different orientations or partial roof shading - on simpler single-string inverters, such a condition reduces output for the whole string, whereas here losses are limited to the shaded string only.
Can the Sofar HYD-LS1-PRO be installed outdoors or in an unheated garage?
Yes, the unit has a wide operating temperature range, covering conditions from harsh frost to high summer heat, making it suitable for installation in a garage, basement, or outdoors. As with any inverter, it should still be shielded from direct sun exposure and moisture to ensure long, trouble-free operation.
Who is the HYD-LS1-PRO series designed for and what problem does it solve?
The HYD-LS1-PRO is aimed at single-family homeowners who want to maximize self-consumption of solar energy and protect against power outages. Combining PV inverter and battery management functions in one device simplifies installation and reduces the number of components needed in an energy storage system.